Open Access. Powered by Scholars. Published by Universities.®

Physics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 12 of 12

Full-Text Articles in Physics

Towards Clinical Microscopic Fractional Anisotropy Imaging, Nico Jj Arezza Aug 2023

Towards Clinical Microscopic Fractional Anisotropy Imaging, Nico Jj Arezza

Electronic Thesis and Dissertation Repository

Microscopic fractional anisotropy (µFA) is a diffusion-weighted magnetic resonance imaging (dMRI) metric that is sensitive to neuron microstructural features without being confounded by the orientation dispersion of axons and dendrites. µFA may potentially act as a surrogate biomarker for neurodegeneration, demyelination, and other pathological changes to neuron microstructure with greater specificity than other dMRI techniques that are sensitive to orientation dispersion, such as diffusion tensor imaging. As with many advanced imaging techniques, µFA is primarily used in research studies and has not seen use in clinical settings.

The primary goal of this Thesis was to assess the clinical viability of …


A Highly Charged Topic: Intrinsically Disordered Proteins And Protein Pka Values, Carter J. Wilson Apr 2023

A Highly Charged Topic: Intrinsically Disordered Proteins And Protein Pka Values, Carter J. Wilson

Electronic Thesis and Dissertation Repository

Intrinsically disordered proteins (IDPs) are known not only for their roles in disease but also for their conformational flexibility, which makes them elusive for experimentation. We consider the role played by theory and simulation in resolving important questions pertaining to IDP structure and dynamics, as well as the nature of the charged residues (e.g., glutamate, lysine, etc.) that enrich them. Specifically, we investigated how the deep learning trained AlphaFold2 (AF2) predictor estimates disorder content, revealing both strong performance in relation to conventional approaches and an important relationship between the AF2 confidence metric and IDP dynamics. We also assessed how modern …


Calculating The Dimensionality Of The Brain, And Other Applications Of An Optimized Generalized Ising Model In Predicting Brain's Spontaneous Functions, Pubuditha M. Abeyasinghe Apr 2019

Calculating The Dimensionality Of The Brain, And Other Applications Of An Optimized Generalized Ising Model In Predicting Brain's Spontaneous Functions, Pubuditha M. Abeyasinghe

Electronic Thesis and Dissertation Repository

Understanding a system as complex as the human brain is a very demanding task. Directly working with structural and functional neuroimaging data has led to most of the understanding we have gained about the human brain. However, performing only the direct statistical comparisons on the empirical function and the structure does not fully explain the observed long-range functional correlations. Therefore, implementations of mathematical models to gain further understanding of the relationship between the structure and function of the brain is critical. Additionally, spontaneous functions of the brain can only be predicted using computer simulated models; which will be pivotal for …


Investigation Of Flow Disturbances And Multi-Directional Wall Shear Stress In The Stenosed Carotid Artery Bifurcation Using Particle Image Velocimetry, Amanda L. Dicarlo Dec 2018

Investigation Of Flow Disturbances And Multi-Directional Wall Shear Stress In The Stenosed Carotid Artery Bifurcation Using Particle Image Velocimetry, Amanda L. Dicarlo

Electronic Thesis and Dissertation Repository

Hemodynamics and shear forces are associated with pathological changes in the vascular wall and its function, resulting in the focal development of atherosclerosis. Flow complexities that develop in the presence of established plaques create environments favourable to thrombosis formation and potentially plaque rupture leading to stroke. The carotid artery bifurcation is a common site of atherosclerosis development. Recently, the multi-directional nature of shear stress acting on the endothelial layer has been highlighted as a risk factor for atherogenesis, emphasizing the need for accurate measurements of shear stress magnitude as well direction. In the absence of comprehensive patient specific datasets numerical …


Performance Impact Of Different Lower-Limb Setup Positions In The Backstroke Swimming Start, Gordon E. Barkwell Aug 2018

Performance Impact Of Different Lower-Limb Setup Positions In The Backstroke Swimming Start, Gordon E. Barkwell

Electronic Thesis and Dissertation Repository

The performance impact of different knee extension angles in the setup position for a backstroke start was evaluated using an instrumented starting surface. Ten backstroke swimmers completed maximum-effort starts in each of two setup positions: one with the knees flexed, and one with the knees extended. The start handles and touchpad were instrumented with tri-axial force plates. Activity of major hip and knee extensors was measured using surface electromyography. Body position was recorded throughout the start using two high-speed cameras. There was no difference in time to 10 m between the two conditions, indicating there is likely no advantage in …


Hyperpolarized 129xe Magnetic Resonance Imaging Of Radiation-Induced Lung Injury, Ozkan Doganay Oct 2015

Hyperpolarized 129xe Magnetic Resonance Imaging Of Radiation-Induced Lung Injury, Ozkan Doganay

Electronic Thesis and Dissertation Repository

Lung cancer is the largest contributor to cancer-related mortality worldwide. Only 20% of stage III non-small cell lung cancer patients survive after 5-years post radiation therapy (RT). Although RT is an important treatment modality for lung cancer, it is limited by Radiation-Induced Lung Injury (RILI). RILI develops in two phases: (i) the early phase (days-weeks) referred to radiation pneumonitis (RP), and (ii) the late phase (months). There is a strong interest in early detection of RP using imaging to improve outcomes of RT for lung cancer. This thesis describes a promising approach based on 129Xe gas as a contrast …


Advances In Image Acquisition And Filtering For Mri Neuroimaging At 7 Tesla, Andrew T. Curtis Sep 2014

Advances In Image Acquisition And Filtering For Mri Neuroimaging At 7 Tesla, Andrew T. Curtis

Electronic Thesis and Dissertation Repository

Performing magnetic resonance imaging at high magnetic field strength promises many improvements over low fields that are of direct benefit in functional neuroimaging. This includes the possibility of improved signal-to-noise levels, and increased BOLD functional contrast and spatial specificity. However, human MRI at 7T and above suffers from unique engineering challenges that limit the achievable gains. In this thesis, three technological developments are introduced, all of which address separate issues associated with functional magnetic resonance neuroimaging at very high magnetic field strengths.

First, the image homogeneity problem is addressed by investigating methods of RF shimming — modifying the excitation portion …


Plasmonic Optical Sensors: Performance Analysis And Engineering Towards Biosensing, Peipei Jia Jun 2014

Plasmonic Optical Sensors: Performance Analysis And Engineering Towards Biosensing, Peipei Jia

Electronic Thesis and Dissertation Repository

Surface plasmon resonance (SPR) sensing for quantitative analysis of chemical reactions and biological interactions has become one of the most promising applications of plasmonics. This thesis focuses on performance analysis for plasmonic sensors and implementation of plamonic optical sensors with novel nanofabrication techniques.

A universal performance analysis model is established for general two-dimensional plasmonic sensors. This model is based on the fundamental facts of surface plasmon theory. The sensitivity only depends on excitation light wavelength as well as dielectric properties of metal and dielectrics. The expression involves no structure-specified parameters, which validates this formula in broad cases of periodic, quasiperiodic …


A Non-Contrast Magnetic Resonance Imaging Technique To Assess Blood-Brain Barrier Permeability, Harini Pandithasekera Jun 2014

A Non-Contrast Magnetic Resonance Imaging Technique To Assess Blood-Brain Barrier Permeability, Harini Pandithasekera

Electronic Thesis and Dissertation Repository

The Blood-brain barrier (BBB) regulates the entry of compounds between the blood and the brain, thus plays an important role in brain homeostasis. Studies indicate in disease states such as Alzheimer’s the BBB integrity is compromised. The motive of this project is to investigate the sensitivity of the diffusion-weighted arterial spin labeling (DW-ASL) technique to detect water exchange. Testing the sensitivity requires a reliable method of opening the barrier at specific locations of the brain. Here, a unique technology named focused ultrasound (FUS) has been used to mimic a compromised BBB environment.

A series of experiments were conducted in a …


Fabricating Cost-Effective Nanostructures For Biomedical Applications, Erden Ertorer Sep 2013

Fabricating Cost-Effective Nanostructures For Biomedical Applications, Erden Ertorer

Electronic Thesis and Dissertation Repository

In this thesis we described inexpensive alternatives to fabricate nanostructures on planar substrates and provided example applications to discuss the efficiency of fabricated nanostructures.

The first method we described is forming large area systematically changing multi-shape nanoscale structures on a chip by laser interference lithography. We analyzed the fabricated structures at different substrate positions with respect to exposure time, exposure angle and associated light intensity profile. We presented experimental details related to the fabrication of symmetric and biaxial periodic nanostructures on photoresist, silicon surfaces, and ion-milled glass substrates. Behavior of osteoblasts and osteoclasts on the nanostructures was investigated. These results …


A Method To Measure The Detective Quantum Efficiency Of Radiographic Systems In Clinical Setting, Michael C. Mcdonald Apr 2012

A Method To Measure The Detective Quantum Efficiency Of Radiographic Systems In Clinical Setting, Michael C. Mcdonald

Electronic Thesis and Dissertation Repository

The risks associated with exposure to radiation make it critical that digital imaging systems give the best possible images for a given dose to the patient. The DQE is the most widely accepted measure of performance and dose efficiency for digital radiography systems, however it is not commonly measured in a clinical environment as part of routine quality assurance. The primary reason for this is that the data provided to the user by clinical systems has typically undergone image processing and therefore may have a non-linear characteristic response. This is a problem because the Fourier metrics of the DQE require …


Exploring Bacterial Nanowires: From Properties To Functions And Implications, Kar Man Leung Aug 2011

Exploring Bacterial Nanowires: From Properties To Functions And Implications, Kar Man Leung

Electronic Thesis and Dissertation Repository

The discovery of electrically conductive bacterial nanowires from a broad range of microbes provides completely new insights into microbial physiology. Shewanella oneidensis strain MR-1, a dissimilatory metal-reducing bacterium, produces extracellular bacterial nanowires up to tens of micrometers long, with a lateral dimension of ~10 nm. The Shewanella bacterial nanowires are efficient electrical conductors as revealed by scanning probe techniques such as CP-AFM and STM.

Direct electrical transport measurements along Shewanella nanowires reveal a measured nanowire resistivity on the order of 1 Ω∙cm. With electron transport rates up to 109/s at 100 mV, bacterial nanowires can serve as a …