Open Access. Powered by Scholars. Published by Universities.®

Physics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 5 of 5

Full-Text Articles in Physics

Analysis Of Human Skin Tissue By Raman Microspectroscopy: Dealing With The Background, Franck Bonnier, Syed Mehmood Ali, Peter Knief, Helen Lambkin, Kathleen Flynn, Vincent Mcdonagh, Claragh Healy, Thomas Lee, Fiona Lyng, Hugh Byrne Jan 2012

Analysis Of Human Skin Tissue By Raman Microspectroscopy: Dealing With The Background, Franck Bonnier, Syed Mehmood Ali, Peter Knief, Helen Lambkin, Kathleen Flynn, Vincent Mcdonagh, Claragh Healy, Thomas Lee, Fiona Lyng, Hugh Byrne

Articles

Raman microspectroscopy is widely used for molecular characterisation of tissue samples. Nevertheless, when working in vitro on tissue sections, the presence of a broad background to the spectra remains problematic and its removal requires advanced methods for pre-processing of the data. To date, research efforts have been primarily devoted to development of techniques of statistical analysis to extract the relevant information contained in the spectra. However, few attempts have been made to understand the origin of the background and to improve the protocols used for the collection of Raman spectra that could lead to the reduction or elimination of the …


In Vitro Analysis Of Immersed Human Tissues By Raman Microspectroscopy, Franck Bonnier, A. Mehmood, Peter Knief, Aidan Meade, Helen Lambkin, Kathleen Flynn, V. Mcdonagh, C. Healy, T. C. Lee, Fiona Lyng, Hugh Byrne Jan 2011

In Vitro Analysis Of Immersed Human Tissues By Raman Microspectroscopy, Franck Bonnier, A. Mehmood, Peter Knief, Aidan Meade, Helen Lambkin, Kathleen Flynn, V. Mcdonagh, C. Healy, T. C. Lee, Fiona Lyng, Hugh Byrne

Articles

Raman microspectroscopy is a powerful tool for the analysis of tissue sections, providing a molecular map of the investigated samples. Nevertheless, data pre-processing and, particularly, the removal of the broad background to the spectra remain problematic. Indeed, the physical origin of the background has not been satisfactorily determined. Using 785 nm as source in a confocal geometry, it is demonstrated for the example of the protein kappa-elastin that the background and resulting quality of the recorded spectrum are dependent on the morphology of the sample. Whereas a fine powder yields a dominant broad background, compressed pellets and solution-cast thin films …


Effects Of High-Flux Neutron Beams On He-3 Cells Polarized In Situ With Spin-Exchange Optical Pumping, E. Babcock, S. Boag, M. Becker, W. C. Chen, T. E. Chupp, T. R. Gentile, Gordon L. Jones, A. K. Petukhov, T. Soldner, T. G. Walker Sep 2009

Effects Of High-Flux Neutron Beams On He-3 Cells Polarized In Situ With Spin-Exchange Optical Pumping, E. Babcock, S. Boag, M. Becker, W. C. Chen, T. E. Chupp, T. R. Gentile, Gordon L. Jones, A. K. Petukhov, T. Soldner, T. G. Walker

Articles

Polarized He-3 produced by spin-exchange optical pumping (SEOP) has potential as a neutron spin filter for polarization and polarization analysis in many neutron-scattering and neutron particle physics applications. The advantage of the SEOP method is its suitability for providing continuous stable polarization over the course of long experiments. However, we have discovered that exposure to high neutron flux leads to additional strong relaxation mechanisms in the optically polarized alkali-metal vapor used to polarize the He-3. At a neutron flux density of 4.7 x 10(9) cm(-2) s(-1), the alkali-metal relaxation rate increased from 100 to 1000 s(-1) leading to reduced alkali-metal …


Optical Properties Of Silica-Mfi Doped Acrylamide-Based Photopolymer, Tzvetanka Babeva, Rosen Todorov, Svetlana Mintova, Temenujka Yovcheva, Izabela Naydenova, Vincent Toal Jan 2009

Optical Properties Of Silica-Mfi Doped Acrylamide-Based Photopolymer, Tzvetanka Babeva, Rosen Todorov, Svetlana Mintova, Temenujka Yovcheva, Izabela Naydenova, Vincent Toal

Articles

The optical properties of acrylamide-based photopolymer doped with pure silica MFI-type zeolites are studied by refractometric and spectrophotometric means. Dynamic Light Scattering and Transmission Electron Microscopy are used for zeolite characterization and laser refractometry and White Light Interferometric profilometry are used for surface characterization of the composites. Refractive indices and absorption coefficients of composites are determined from their transmittance and reflectance spectra. The calculated dispersion curves are further used for deriving the zeolites refractive index and porosity and the latter compared to the values of total pore volume obtained from N2-sorption measurements. The impact of the doping level on the …


Sans Polarization Analysis With Nuclear-Spin-Polarized He-3, T. R. Gentile, Gordon L. Jones, A. K. Thompson, J. Barker, C. J. Glinka, B. Hammouda, J. W. Lynn Jun 2000

Sans Polarization Analysis With Nuclear-Spin-Polarized He-3, T. R. Gentile, Gordon L. Jones, A. K. Thompson, J. Barker, C. J. Glinka, B. Hammouda, J. W. Lynn

Articles

A neutron spin filter based on transmission through nuclear-spin-polarized He-3 gas has been applied to polarization analysis of small angle neutron scattering (SANS). Such spin filters, which are based on the large spin dependence of the absorption of neutrons by He-3, make SANS polarization analysis possible because of their large angular acceptance. In the present experiment, a He-3-based analyzer was employed to separate nuclear scattering into its coherent and spin-incoherent components. Polarized He-3 analyzers were prepared by two different optical pumping methods and installed on the NG3 SANS instrument at the NIST Center for Neutron Research (NCNR). Measurements were taken …