Open Access. Powered by Scholars. Published by Universities.®

Physics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 31 - 50 of 50

Full-Text Articles in Physics

Investigation Of The Influence Of High Risk Human Papillomavirus On The Biochemical Composition Of Cervical Cancer Cells Using Vibrational Spectroscopy, Kamila Ostrowska, Alison Malkin, Aidan Meade, John O'Leary, Cara Martin, Cathy Spillane, Hugh Byrne, Fiona Lyng Jan 2010

Investigation Of The Influence Of High Risk Human Papillomavirus On The Biochemical Composition Of Cervical Cancer Cells Using Vibrational Spectroscopy, Kamila Ostrowska, Alison Malkin, Aidan Meade, John O'Leary, Cara Martin, Cathy Spillane, Hugh Byrne, Fiona Lyng

Articles

The main aetiology of cervical cancer is infection with high risk human papillomavirus (HPV). Cervical cancer is almost 100% curable if detected in the early stages. Thus, information about the presence and levels of HPV in patient samples has high clinical value. As current screening methods, such as the Pap smear test, are highly subjective and in many cases show low sensitivity and specificity, new supportive techniques are desirable to improve the quality of cervical cancer screening. In this study, vibrational spectroscopic techniques (Raman and Fourier Transform Infra Red absorption) have been applied to the investigation of four cervical cancer …


A Systematic Study Of The Dispersion Of Swnts In Organic Solvents, Qiaohuan Cheng, Sourabhi Debnath, Luke O'Neill, Theresa Hedderman, Elizabeth Gregan, Hugh Byrne Jan 2010

A Systematic Study Of The Dispersion Of Swnts In Organic Solvents, Qiaohuan Cheng, Sourabhi Debnath, Luke O'Neill, Theresa Hedderman, Elizabeth Gregan, Hugh Byrne

Articles

Dispersions of as-produced HiPco single-walled carbon nanotubes (SWNTs) in a series of organic solvents were prepared by dilution with the aid of tip sonication. Mild centrifugation (~ 945 g) was carried out to remove large bundles. Atomic force microscopy (AFM) studies revealed that the bundle size decreased as the dispersion was diluted. By measuring the UV-vis-NIR absorption before and after centrifugation as a function of the concentration, the dispersion limit of SWNTs in each solvent can be determined. Correlations between the dispersion limit and solvent solubility parameters, including the Hildebrand solubility parameter and three dimensional Hansen solubility parameters, are explored, …


Real-Time Plasma Controlled Chemistry In A Two-Frequency, Confined Plasma Etcher, Vladimir Milosavljevic, Albert R. Ellingboe, Cezar Gaman, John V. Ringwood Apr 2008

Real-Time Plasma Controlled Chemistry In A Two-Frequency, Confined Plasma Etcher, Vladimir Milosavljevic, Albert R. Ellingboe, Cezar Gaman, John V. Ringwood

Articles

The physics issues of developing model-based control of plasma etching are presented. A novel methodology for incorporating real-time model-based control of plasma processing systems is developed. The methodology is developed for control of two dependent variables (ion flux and chemical densities) by two independent controls (27 MHz power and O2flow). A phenomenological physics model of the nonlinear coupling between the independent controls and the dependent variables of the plasma is presented. By using a design of experiment, the functional dependencies of the response surface are determined. In conjunction with the physical model, the dependencies are used to deconvolve the sensor …


Practical Sensor For Measurement Of Nitrogen, Dusan Popovic, Vladimir Milosavljevic, Steven Daniels Nov 2007

Practical Sensor For Measurement Of Nitrogen, Dusan Popovic, Vladimir Milosavljevic, Steven Daniels

Articles

This paper presents a method for precise measurement of atomic and molecular nitrogen in an oxygen-nitrogen dc plasma. This is achieved by monitoring the intensities of the atomic nitrogen spectral line at 821.6 nm and the molecular nitrogen bandhead at 337.1 nm, relative to the atomic oxygen spectral line at 844.7 nm. Oxygen is one of the most frequently used gases for surface chemical treatment, including deposition and etching, therefore the ability to measure and control the process and chemical composition of the process is essential. To validate this oxygen actimometry method for N2-xO2 (where x varies from 0 to …


Diffusion And Fractional Diffusion Based Models For Multiple Light Scattering And Image Analysis, Jonathan Blackledge Jan 2007

Diffusion And Fractional Diffusion Based Models For Multiple Light Scattering And Image Analysis, Jonathan Blackledge

Articles

This paper considers a fractional light diffusion model as an approach to characterizing the case when intermediate scattering processes are present, i.e. the scattering regime is neither strong nor weak. In order to introduce the basis for this approach, we revisit the elements of formal scattering theory and the classical diffusion problem in terms of solutions to the inhomogeneous wave and diffusion equations respectively. We then address the significance of these equations in terms of a random walk model for multiple scattering. This leads to the proposition of a fractional diffusion equation for modelling intermediate strength scattering that is based …


Measured Stark Widths And Shifts Of The Neutral Argon Spectral Lines In 4s–4p And 4s–4p′ Transitions, Vladimir Milosavljevic, Albert R. Ellingboe, Stevan Djenize Jan 2006

Measured Stark Widths And Shifts Of The Neutral Argon Spectral Lines In 4s–4p And 4s–4p′ Transitions, Vladimir Milosavljevic, Albert R. Ellingboe, Stevan Djenize

Articles

We investigate the Stark widths (W) and the shift (d), of the seven neutral argon (Ar I) spectral lines from the 4s–4p and 4s–4p′ transitions. The line shapes are measured in a linear, low-pressure, optically thin pulsed arc discharge at about 16 000 K electron temperature (T) and about 7.0 × 1022 m− 3 electron density (N). The new data separates the electron width (We) and ion width Wi from the total Stark width (Wt), as well the separation of electron total Stark …


Stark Width And Shift Of The Neutral Argon 425.9 Nm Spectral Line, Vladimir Milosavljevic, Vida Zigman, Stevan Djenize Sep 2004

Stark Width And Shift Of The Neutral Argon 425.9 Nm Spectral Line, Vladimir Milosavljevic, Vida Zigman, Stevan Djenize

Articles

The Stark parameters, the width (W) and the shift (d), of the neutral argon (Ar I) 425.9 nm spectral line have been studied in a linear, low-pressure, optically thin pulsed arc discharge. The line shapes are measured in three different plasmas at about 16,000 K electron temperature (T) and about 7.0×1022 m−3 electron density (N). The separate electron and ion contributions to the total Stark width (Wt), i.e. We and Wi, as well as to the total Stark shift (dt), i.e. …


Transition Probabilities In Kr Ii And Kr Iii Spectra, Stevan Djenize, Vladimir Milosavljevic, Milan S. Dimitrijevic Sep 2003

Transition Probabilities In Kr Ii And Kr Iii Spectra, Stevan Djenize, Vladimir Milosavljevic, Milan S. Dimitrijevic

Articles

On the basis of the relative line intensity ratio (RLIR) method, transition probability values of the spontaneous emission (Einstein's A values) of 14 transitions in the singly (Kr II) and 7 transitions in doubly (Kr III) ionized krypton spectra have been obtained relatively to the reference A values related to the 435.548 nm Kr II and 324.569 nm Kr III, the most intensive transitions in the Kr II and Kr III spectra. Our Kr III transition probability values are the first data obtained experimentally using the RLIR method. A linear, low–pressure, pulsed arc operated in krypton discharge was used as …


Astrophysical Plasma Diagnostics Through Analysis Of Ar Iine Shape Characteristics, Vladimir Milosavljevic, Stevan Djenize Jul 2003

Astrophysical Plasma Diagnostics Through Analysis Of Ar Iine Shape Characteristics, Vladimir Milosavljevic, Stevan Djenize

Articles

On the basis of five accurately recorded neutral argon ( ) line shapes (in the 4s-5p transition) we have recovered the basic plasma parameters i.e. electron temperature ( T) and electron density ( N) using our new line deconvolution procedure in the case of three different plasmas created in a linear, low-pressure, pulsed arc discharge. The mentioned plasma parameters have also been measured using independent experimental diagnostic techniques. An excellent agreement has been found among the two sets of obtained parameters. This recommends our deconvolution procedure for plasma diagnostic purposes, especially in astrophysics where direct measurements of the …


Experimental And Calculated Stark Widths Within The Kr I Spectrum, Vladimir Milosavljevic, Stevan Djenize, Milan S. Dimitrijevic Jul 2003

Experimental And Calculated Stark Widths Within The Kr I Spectrum, Vladimir Milosavljevic, Stevan Djenize, Milan S. Dimitrijevic

Articles

On the basis of the precisely recorded 20 neutral krypton (Kr I) line shapes (in the 5s−5p and 5s−6p transitions), we have obtained the basic plasma parameters, i.e., electron temperature (T) and electron density (N) using our line deconvolution procedure in a plasma created in a linear, low-pressure, pulsed arc discharge operated in krypton. The mentioned plasma parameters have also been measured using independent experimental diagnostics techniques. Agreement has been found among the two sets of the obtained parameters. This recommends our deconvolution procedure for plasma diagnostical purposes, especially in astrophysics where direct measurements of the …


Reply To "Comment On ‘Atomic Spectral Line Free-Parameter Deconvolution Procedure’”, Vladimir Milosavljevic, Goran Poparic May 2003

Reply To "Comment On ‘Atomic Spectral Line Free-Parameter Deconvolution Procedure’”, Vladimir Milosavljevic, Goran Poparic

Articles

We do not agree with the authors of the preceding Comment [X. Nikolic, X. Ojurovic, and X. Mijatovic, Phys. Rev. E, 67, 058401, 2003]. Our numerical procedure for the deconvolution of the theoretical asymmetric convolution integral of a Gaussian and a plasma broadened spectral line profile jA,R(λ) for spectral lines enables the determination of all broadening parameters. All broadening parameters can be determined directly from the recorded line profile of a single line, with minimal assumptions or prior knowledge. Additional experimental diagnostics are not required.


The He I 706.52 Nm Line Shape Characteristics In The Plasma Diagnostics, Vladimir Milosavljevic, Stevan Djenize Apr 2003

The He I 706.52 Nm Line Shape Characteristics In The Plasma Diagnostics, Vladimir Milosavljevic, Stevan Djenize

Articles

On the basis of the precisely recorded 706.52 nm He I line shape we have obtained the basic plasma parameters i.e. electron temperature (T) and electron density (N) using our new line deconvolution procedure in the case of five various plasmas created in a linear, low–pressure, pulsed arc discharge. Plasma parameters have been also measured using independent experimental diagnostical techniques. Excellent agreement was found among the two sets of the obtained parameters. This enables our deconvolution procedure to recommendation for plasma diagnostical purposes, especially in astrophysics where direct measurements of the plasma parameters (T and …


Ion Contribution To The Astrophysical Important 447.15, 587.56 And 667.82 Nm He I Spectral Lines Broadening, Vladimir Milosavljevic, Stevan Djenize Oct 2002

Ion Contribution To The Astrophysical Important 447.15, 587.56 And 667.82 Nm He I Spectral Lines Broadening, Vladimir Milosavljevic, Stevan Djenize

Articles

Characteristics of the astrophysical important Stark broadened 447.15 nm, 587.56 nm and 667.82 nm spectral line profiles have been measured at electron densities between 0.3 10 and 8.2 10 m and electron temperatures between 8000 and 33 000 K in plasmas created in five various discharge conditions using a linear, low-pressure, pulsed arc as an optically thin plasma source operated in a helium-nitrogen-oxygen gas mixture. On the basis of the observed asymmetry of the line profiles we have obtained their ion broadening parameters ( A) caused by influence of the ion microfield on the line broadening mechanism and also …


Stark Shifts And Transition Probabilities In The Ne Ii Spectrum, Stevan Djenize, Vladimir Milosavljevic, Milan S. Dimitrijevic Jan 2002

Stark Shifts And Transition Probabilities In The Ne Ii Spectrum, Stevan Djenize, Vladimir Milosavljevic, Milan S. Dimitrijevic

Articles

Stark shifts (d) and transition probabilities of the spontaneous emission (Einstein's A values) of forty two singly charged neon ( ) ion spectral lines have been measured in a linear, low pressure, pulsed arc at 35 300 K electron temperature and 1.83 10 23 m -3 electron density. Transition probabilities have been obtained using the relative line intensity ratio (RLIR) method. Stark shift values have also been calculated, using the semiclassical perturbation formalism (SCPF). The measured and calculated shift values and the measured A values have been compared to the existing data taken from available data sources.


Production Of A Signal By Irradiated Cells Which Leads To A Response In Unirradiated Cells Characteristic Of Initiation Of Apoptosis, Fiona Lyng, C. Seymour, C. Mothersill Jan 2000

Production Of A Signal By Irradiated Cells Which Leads To A Response In Unirradiated Cells Characteristic Of Initiation Of Apoptosis, Fiona Lyng, C. Seymour, C. Mothersill

Articles

This study investigated the ability of medium from irradiated cells to induce early events in the apoptotic cascade, such as mobilization of intracellular calcium, loss of mitochondrial membrane potential and increase in reactive oxygen species, in cells which were never exposed to radiation. Medium from irradiated human keratinocytes was harvested and transferred to unirradiated keratinocytes. Endpoints characteristic of the initiation of apoptosis were monitored for a period of 24 h following medium transfer. Clonogenic survival was also measured. Rapid calcium fluxes (within 30 s), loss of mitochondrial membrane potential, increases in reactive oxygen species (from 6 h after medium transfer), …


Temperature Dependence Of Stark Width Of The 463.054 Nm Nii Spectral Line, Vladimir Milosavljevic, Ruzica Konjevic, Stevan Djenize Mar 1999

Temperature Dependence Of Stark Width Of The 463.054 Nm Nii Spectral Line, Vladimir Milosavljevic, Ruzica Konjevic, Stevan Djenize

Articles

Stark width of the 463.054 nm singly ionized nitrogen spectral line, that belong to transition, have been measured in a linear pulsed, low pressure, arc discharge. The working gas was helium-nitrogen-oxygen mixture. Electron densities of 0.751023 to 1.451023 were determined in the electron temperature range between 30000 K - 38000 K. The measured values have been compared with our calculated data, using the modified semiempirical approximation. On the basis of the agreement among experimental and theoretical Stark width data, the isolated 463.054 nm NII spectral line can be recommended as convenient spectral line for plasma diagnostics.


Measured Stark Widths And Shifts Of Several Niii Sectral Lines: Temperature Dependence, Stevan Djenize, Vladimir Milosavljevic Aug 1998

Measured Stark Widths And Shifts Of Several Niii Sectral Lines: Temperature Dependence, Stevan Djenize, Vladimir Milosavljevic

Articles

Stark parameters (width and shift) of four doubly ionized nitrogen spectral lines, that belong to 3s-3p and 3p-3d transitions (lower multiplets), have been measured in a linear pulsed, low pressure, arc discharge in the nitrogen-oxygen and helium-nitrogen-oxygen plasmas in a (30 000 - 54 000) K electron temperature and a (0.75 1023 - 2.8 1023) electron density ranges. The measured values have been compared to the existing experimental and calculated data.


On The Stark Broadening Parameters Of The Two Nii Spectral Lines Of The 3d-4f Transition, Vladimir Milosavljevic, Stevan Djenize Jun 1997

On The Stark Broadening Parameters Of The Two Nii Spectral Lines Of The 3d-4f Transition, Vladimir Milosavljevic, Stevan Djenize

Articles

Stark parameters (width and shift) of two singly ionized nitrogen spectral lines, that belong to 3d-4f transition have been measured in a linear pulsed, low pressure, arc discharge in the nitrogen-oxygen plasma at a 54000 K electron temperature and at a 2.8×10 23 m−3 electron density. The measured values have been compared to the existing experimental and calculated data


Measured Stark Widths Of A 425,94 Nm Ari Spectral Line, Ljiljana Skuljan, Vladimir Milosavljevic, Aleksandar Sreckovic, Stevan Djenize Dec 1995

Measured Stark Widths Of A 425,94 Nm Ari Spectral Line, Ljiljana Skuljan, Vladimir Milosavljevic, Aleksandar Sreckovic, Stevan Djenize

Articles

No abstract provided.


Experimental Stark Shift Of Several Nii And Oii Spectral Lines, Mara Scepanovic, Vladimir Milosavljevic, Stevan Djenize, Mihajlo Platisa, Jaroslav Labat Jun 1994

Experimental Stark Shift Of Several Nii And Oii Spectral Lines, Mara Scepanovic, Vladimir Milosavljevic, Stevan Djenize, Mihajlo Platisa, Jaroslav Labat

Articles

Stark shift of four NII and seven OII spectral lines have been measured for the first time in the linear low pressure pulsed arc plasma and compared with existing theoretical values.