Open Access. Powered by Scholars. Published by Universities.®

Physics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 5 of 5

Full-Text Articles in Physics

Measurement And Modeling Of Infrared Nonlinear Absorption Coefficients And Laser-Induced Damage Thresholds In Ge And Gasb, Torrey J. Wagner, Matthew J. Bohn, Ronald A. Coutu Jr., L. P. Gonzales, J. M. Murray, K. L. Schepler, S. Guha Oct 2010

Measurement And Modeling Of Infrared Nonlinear Absorption Coefficients And Laser-Induced Damage Thresholds In Ge And Gasb, Torrey J. Wagner, Matthew J. Bohn, Ronald A. Coutu Jr., L. P. Gonzales, J. M. Murray, K. L. Schepler, S. Guha

Faculty Publications

Using a simultaneous fitting technique to extract nonlinear absorption coefficients from data at two pulse widths, we measure two-photon and free-carrier absorption coefficients for Ge and GaSb at 2.05 and 2.5 µm for the first time, to our knowledge. Results agreed well with published theory. Single-shot damage thresholds were also measured at 2.5 µm and agreed well with modeled thresholds using experimentally determined parameters including nonlinear absorption coefficients and temperature dependent linear absorption. The damage threshold for a single-layer Al2O3 anti-reflective coating on Ge was 55% or 35% lower than the uncoated threshold for picosecond or nanosecond …


Hard Collisions In Rubidium Using Sub-Doppler Spectroscopy, Douglas E. Thornton Mar 2010

Hard Collisions In Rubidium Using Sub-Doppler Spectroscopy, Douglas E. Thornton

Theses and Dissertations

To better understand the laser kinetics of an alkali gain medium, hard collisions, or velocity-changing collisions, has been studied and a velocity-changing collisional rate has been calculated. Previous works have studied these collisions, but no rate has been calculated. Using the precise tool of sub-Doppler spectroscopy, atomic hard collisions can be observed. The collected spectra are fitted with two different line shapes to demonstrate the accuracy of this method. From the fits, the number of hard collisions can be extracted. The time scale of the hard collisions in rubidium is interpolated by varying the chopping frequency of the pump beam, …


Positron Annihilation Ratio Spectroscopy (Psars) Applied To Positronium Formation Studies, Robert C. Slaughter Mar 2010

Positron Annihilation Ratio Spectroscopy (Psars) Applied To Positronium Formation Studies, Robert C. Slaughter

Theses and Dissertations

A Positron Annihilation of Radiation Spectrometer (PsARS) was developed and characterized. PsARS spectroscopy as well as digital Positron Annihilation Lifetime Spectroscopy (PALS) was applied to measure positronium formation on gold nanoparticles deposited through an evaporative method onto a thin capillary tube. This gold coated capillary tube was designed to be used for positronium lifetime studies in local electric field experiments. High local electric fields can polarize a positron-electron pair, which may result in an extended lifetime of the positron. These fields may be created through the interaction of an external electric field with silver nanoparticles deposited onto the surface of …


Passive Ranging Using Infra-Red Atmospheric Attenuation, Douglas J. Macdonald Mar 2010

Passive Ranging Using Infra-Red Atmospheric Attenuation, Douglas J. Macdonald

Theses and Dissertations

Methods of estimating range to an emissive target based on the depth of an atmospheric absorption band are demonstrated. The present work uses measurements of the CO2 absorption band centered at 2.0 µm where signal-to-background ratios are maximum for many applications. Model results, based on high-resolution transmission molecular absorption (HITRAN) database cross sections, are used to predict range accuracy at ranges of up to 50 km and are compared with short range (<5km) experimental results. The spectra of 23 high explosive events were used to validate the model. Using the assumption of a blackbody spectrum, extracted ranges consistently underestimated the true range by approximately 13%. By incorporating the stoichiometry of the fireball from previous research and using particulate contribution as a parameter, the error for the range estimates could be reduced to 3%.


Scene Change Artifacts In Fourier Transform Spectroscopy Of Temporally Changing Sources, Anthony M. Young Mar 2010

Scene Change Artifacts In Fourier Transform Spectroscopy Of Temporally Changing Sources, Anthony M. Young

Theses and Dissertations

Improved understanding of midwave infrared (1-5 micron) spectral emissions from detonation fireballs is needed to develop phenomenological models for battle space optical forensics. The ability to measure radiance over a wide band pass at arbitrary resolutions make Fourier-transform spectrometers (FTS) an attractive tool. However, interferometer based spectroscopic measurements can be corrupted when the observed intensity changes during data acquisition. While small, random fluctuations in scene intensity translate into noise, systematic variations introduce scene-change artifacts (SCAs) into Fourier-transformed spectrum.