Open Access. Powered by Scholars. Published by Universities.®

Physical Sciences and Mathematics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 31 - 40 of 40

Full-Text Articles in Physical Sciences and Mathematics

Scanned Ion Beam Therapy For Thoracic Tumors, John Gordon Eley Dec 2013

Scanned Ion Beam Therapy For Thoracic Tumors, John Gordon Eley

Dissertations & Theses (Open Access)

Although frequently cured of Hodgkin lymphoma, adolescents and young adults can develop radiation induced second cancers. These patients could potentially benefit from scanned ion radiotherapy yet likely would require motion mitigation strategies. In theory, four-dimensional (4D) optimization of ion beam fields for individual motion states of respiration can enable superior sparing of healthy tissue near moving targets, compared to other motion mitigation strategies. Furthermore, carbon-ion therapy can sometimes provide greater relative biological effectiveness (RBE) for cell sterilization in a target but nearly equivalent RBE in tissue upstream of the target, compared to proton therapy. Thus, we expected that for some …


Radiogenic Second Cancer Risk Differences In Female Hodgkin Lymphoma Patients Treated With Proton Versus Photon Radiotherapies, Kenneth L. Homann Dec 2013

Radiogenic Second Cancer Risk Differences In Female Hodgkin Lymphoma Patients Treated With Proton Versus Photon Radiotherapies, Kenneth L. Homann

Dissertations & Theses (Open Access)

Hodgkin Lymphoma (HL) is the most common cancer diagnosis of young adults in the United States. Advances in curative treatments for HL, including the use of photon radiation therapy (RT) techniques, have increased 10 year survival rates to approximately 90% among young patients. These RT treatments, however, contribute to an increased incidence of radiogenic second cancer (RSC) formation to the healthy tissue surrounding the tumor volume relative to the general population. These RSCs are the leading cause of death among long-term HL survivors. Proton therapy has been shown to reduce the therapeutic dose, and therefore, the risk of developing a …


The Development And Implementation Of An Anthropomorphic Head Phantom For The Assessment Of Proton Therapy Treatment Procedures, Paige A. Summers Aug 2011

The Development And Implementation Of An Anthropomorphic Head Phantom For The Assessment Of Proton Therapy Treatment Procedures, Paige A. Summers

Dissertations & Theses (Open Access)

Proton therapy has become an increasingly more common method of radiation therapy, with the dose sparing to distal tissue making it an appealing option, particularly for treatment of brain tumors. This study sought to develop a head phantom for the Radiological Physics Center (RPC), the first to be used for credentialing of institutions wishing to participate in clinical trials involving brain tumor treatment of proton therapy. It was hypothesized that a head phantom could be created for the evaluation of proton therapy treatment procedures (treatment simulation, planning, and delivery) to assure agreement between the measured dose and calculated dose within …


Clinical Impact Of Couch Top And Rails On Imrt And Arc Therapy, Kiley B. Pulliam Aug 2011

Clinical Impact Of Couch Top And Rails On Imrt And Arc Therapy, Kiley B. Pulliam

Dissertations & Theses (Open Access)

Purpose: To evaluate the clinical impact of the Varian Exact Couch on dose and volume coverage to targets and critical structures and tumor control probability (TCP) for 6-MV IMRT and Arc Therapy.

Methods: Five clinical prostate patients were planned with both, 6-MV 8-field IMRT and 6-MV 2-field RapidArc using the Eclipse treatment planning system (TPS). These plans neglected treatment couch attenuation, as is standard clinical practice. Dose distributions were then recalculated in Eclipse with the inclusion of the Varian Exact Couch (imaging couch top) and the rails in varying configurations. The changes in dose and coverage were evaluated using the …


Risk Of Second Malignant Neoplasms Following Proton Arc Therapy And Volumetric Modulated Arc Therapy For Prostate Cancer, Laura A. Rechner May 2011

Risk Of Second Malignant Neoplasms Following Proton Arc Therapy And Volumetric Modulated Arc Therapy For Prostate Cancer, Laura A. Rechner

Dissertations & Theses (Open Access)

The risk of second malignant neoplasms (SMNs) following prostate radiotherapy is a concern due to the large population of survivors and decreasing age at diagnosis. It is known that parallel-opposed beam proton therapy carries a lower risk than photon IMRT. However, a comparison of SMN risk following proton and photon arc therapies has not previously been reported. The purpose of this study was to predict the ratio of excess relative risk (RRR) of SMN incidence following proton arc therapy to that after volumetric modulated arc therapy (VMAT). Additionally, we investigated the impact of margin size and the effect …


Characterization Of Optically Stimulated Luminescent Detectors In Photon & Proton Beams For Use In Anthropomorphic Phantoms, James R. Kerns Aug 2010

Characterization Of Optically Stimulated Luminescent Detectors In Photon & Proton Beams For Use In Anthropomorphic Phantoms, James R. Kerns

Dissertations & Theses (Open Access)

This study investigated characteristics of optically stimulated luminescent detectors (OSLDs) in protons, allowing comparison to thermoluminescent detectors, and to be implemented into the Radiological Physics Center’s (RPC) remote audit quality assurance program for protons, and for remote anthropomorphic phantom irradiations. The OSLDs used were aluminum oxide (Al2O3:C) nanoDots from Landauer, Inc. (Glenwood, Ill.) measuring 10x10x2 mm3. A square, 20(L)x20(W)x0.5(H) cm3 piece of solid water was fabricated with pockets to allow OSLDs and TLDs to be irradiated simultaneously and perpendicular to the beam. Irradiations were performed at 5cm depth in photons, and in the center of a 10 cm SOBP in …


Dynamic Chemical Shift Imaging For Image-Guided Thermal Therapy, Brian A. Taylor Aug 2010

Dynamic Chemical Shift Imaging For Image-Guided Thermal Therapy, Brian A. Taylor

Dissertations & Theses (Open Access)

Magnetic resonance temperature imaging (MRTI) is recognized as a noninvasive means to provide temperature imaging for guidance in thermal therapies. The most common method of estimating temperature changes in the body using MR is by measuring the water proton resonant frequency (PRF) shift. Calculation of the complex phase difference (CPD) is the method of choice for measuring the PRF indirectly since it facilitates temperature mapping with high spatiotemporal resolution. Chemical shift imaging (CSI) techniques can provide the PRF directly with high sensitivity to temperature changes while minimizing artifacts commonly seen in CPD techniques. However, CSI techniques are currently limited by …


An Implantable Mosfet Dosimeter Modified To Act As A Fiducial Marker, Joseph S. Dick Aug 2010

An Implantable Mosfet Dosimeter Modified To Act As A Fiducial Marker, Joseph S. Dick

Dissertations & Theses (Open Access)

In external beam radiation therapy, it is imperative that the prescribed dose is administered to the correct location and in the correct amount. Though several ex vivo methods of quality assurance are currently employed to achieve this goal, verifying that the correct dose is received within the patient in situ is impossible without the capability of measuring dose inside the patient. Recently, a method of measuring dose delivered within the patient has been developed, an implantable MOSFET dosimeter. This dosimeter is implanted within the patient and records the dose received. Since the dosimeter is implanted in the patient, it could …


Benchmarking And Implementation Of A New Independent Monte Carlo Dose Calculation Quality Assurance Audit Tool For Clinical Trials, Scott E. Davidson Aug 2010

Benchmarking And Implementation Of A New Independent Monte Carlo Dose Calculation Quality Assurance Audit Tool For Clinical Trials, Scott E. Davidson

Dissertations & Theses (Open Access)

Introduction Commercial treatment planning systems employ a variety of dose calculation algorithms to plan and predict the dose distributions a patient receives during external beam radiation therapy. Traditionally, the Radiological Physics Center has relied on measurements to assure that institutions participating in the National Cancer Institute sponsored clinical trials administer radiation in doses that are clinically comparable to those of other participating institutions. To complement the effort of the RPC, an independent dose calculation tool needs to be developed that will enable a generic method to determine patient dose distributions in three dimensions and to perform retrospective analysis of radiation …


Thoracic Radiotherapy Treatment Planning With Cine Pet/Ct, Adam C. Riegel May 2010

Thoracic Radiotherapy Treatment Planning With Cine Pet/Ct, Adam C. Riegel

Dissertations & Theses (Open Access)

Purpose: Respiratory motion causes substantial uncertainty in radiotherapy treatment planning. Four-dimensional computed tomography (4D-CT) is a useful tool to image tumor motion during normal respiration. Treatment margins can be reduced by targeting the motion path of the tumor. The expense and complexity of 4D-CT, however, may be cost-prohibitive at some facilities. We developed an image processing technique to produce images from cine CT that contain significant motion information without 4D-CT. The purpose of this work was to compare cine CT and 4D-CT for the purposes of target delineation and dose calculation, and to explore the role of PET in target …