Open Access. Powered by Scholars. Published by Universities.®

Epidemiology Commons

Open Access. Powered by Scholars. Published by Universities.®

2010

Medical Specialties

Humans

Articles 1 - 3 of 3

Full-Text Articles in Epidemiology

Body Mass Index, Treatment Practices, And Mortality In Patients With Acute Heart Failure, Timothy Fitzgibbons, Olga Hardy, Darleen Lessard, Joel Gore, Jorge Yarzebski, Robert Goldberg Jul 2010

Body Mass Index, Treatment Practices, And Mortality In Patients With Acute Heart Failure, Timothy Fitzgibbons, Olga Hardy, Darleen Lessard, Joel Gore, Jorge Yarzebski, Robert Goldberg

Jorge L. Yarzebski

OBJECTIVES: Obesity is associated with an increased risk of heart failure (HF). Among patients presenting with acute HF, however, differences in clinical characteristics, treatment regimens, and short-term prognosis of varying weights are largely unknown, particularly from a broader population-based perspective. METHODS: A total of 3722 patients admitted with acute HF to 11 greater Worcester (Massachusetts, USA) hospitals during 1995 and 2000 were categorized as being lean (n = 216), normal weight (n = 1465), overweight (n = 1007), or obese (n = 1034) at the time of hospitalization. RESULTS: Obese patients with decompensated HF were significantly younger (mean age = …


Erroneous Measurement Of Intracranial Pressure Caused By Simultaneous Ventricular Drainage: A Hydrodynamic Model Study, H. Wilkinson, Jorge Yarzebski, E. Wilkinson, Frederick Anderson Jul 2010

Erroneous Measurement Of Intracranial Pressure Caused By Simultaneous Ventricular Drainage: A Hydrodynamic Model Study, H. Wilkinson, Jorge Yarzebski, E. Wilkinson, Frederick Anderson

Jorge L. Yarzebski

Intracranial pressure (ICP) is often measured from intraventricular catheters, a technique that allows therapeutic drainage of ventricular cerebrospinal fluid (CSF) as an aid in controlling ICP and circumventing obstruction. Drainage of CSF simultaneously with ongoing ICP measurement has been advocated as safe and efficient, and devices are commercially available to permit this practice; however, this concept has been seriously challenged, based on clinical observations. The inaccuracy induced by simultaneous CSF drainage and ICP monitoring is quantitated in this report in a mechanical brain model using a standard ventricular catheter. The following conclusions have been confirmed: 1) rapid CSF drainage induces …


T2 And T3 Sympathetic Ganglia In The Adult Human: A Cadaver And Clinical-Radiographic Study And Its Clinical Application, Jorge Yarzebski, H. Wilkinson Jul 2010

T2 And T3 Sympathetic Ganglia In The Adult Human: A Cadaver And Clinical-Radiographic Study And Its Clinical Application, Jorge Yarzebski, H. Wilkinson

Jorge L. Yarzebski

The technique of percutaneous radiofrequency (RF) upper thoracic sympathectomy mandates an exact knowledge of the anatomical location of the sympathetic ganglia. Because conflicting descriptions are given in anatomy texts, we examined the T2 and T3 sympathetic ganglia in 48 sympathetic chains in adult cadavers to measure the exact location of the ganglia. Measurements were made relative to their distances (a) dorsal to the ventral surface of the vertebral body and (b) rostral or caudal to the midpoint of the vertebral body. Median locations of T2 and T3 ganglia were 17 to 20 mm dorsal to the ventral surface of the …