Open Access. Powered by Scholars. Published by Universities.®

Radiology Commons

Open Access. Powered by Scholars. Published by Universities.®

Himmelfarb Health Sciences Library, The George Washington University

Analytical, Diagnostic and Therapeutic Techniques and Equipment

Articles 1 - 5 of 5

Full-Text Articles in Radiology

Needs Assessment Of Pediatric Radiological Equipment And Cross-Cultural Investigation Into Parental Empowerment In Pediatric Radiology Program Development In The Kingdom Of Bhutan, Danielle Canter Apr 2017

Needs Assessment Of Pediatric Radiological Equipment And Cross-Cultural Investigation Into Parental Empowerment In Pediatric Radiology Program Development In The Kingdom Of Bhutan, Danielle Canter

GW Research Days 2016 - 2020

Background:

Bhutan is a magnificent mountainous country hugged by India to the east and west and by China to the North and South. This peaceful nestled country faces challenges in combating non-communicable diseases due to the lack of radiological equipment necessary for early diagnosis. Prior to implementation of these medical devices, it is imperative to investigate the cultural attitudes, beliefs, and infrastructure, to ensure successful integration. Bhutan is beginning to implement a pediatric radiology program for the nation with the assistance of ABAH Foundation and RAD-AID International, both of whom partnered with graduate students at George Washington University School of …


Ct And Pet Findings For Urachal Adenocarcinoma: A Case Report, Merissa Zeman, Ethan Silver, Esma A. Akin Jan 2017

Ct And Pet Findings For Urachal Adenocarcinoma: A Case Report, Merissa Zeman, Ethan Silver, Esma A. Akin

Radiology Faculty Publications

As urachal adenocarcinomas are rare cancers, experience with diagnosing and staging them are limited. To help illustrate CT and PET imaging findings and the role they each play in the workup of urachal adenocarcinomas, we present the case of a 43 y.o. male who was diagnosed at our institution with a T3aN0M0 high grade mucin-producing urachal adenocarcinoma.


Composite Iron Oxide–Prussian Blue Nanoparticles For Magnetically Guided T1-Weighted Magnetic Resonance Imaging And Photothermal Therapy Of Tumors, Shraddha Kale, Rachel Burga, Elizabeth E. Sweeney, Zungho Zun, Raymond Sze, Anthony Tuesca, J Anand Subramony, Rohan Fernandes Jan 2017

Composite Iron Oxide–Prussian Blue Nanoparticles For Magnetically Guided T1-Weighted Magnetic Resonance Imaging And Photothermal Therapy Of Tumors, Shraddha Kale, Rachel Burga, Elizabeth E. Sweeney, Zungho Zun, Raymond Sze, Anthony Tuesca, J Anand Subramony, Rohan Fernandes

Radiology Faculty Publications

Theranostic nanoparticles offer the potential for mixing and matching disparate diagnostic and therapeutic functionalities within a single nanoparticle for the personalized treatment of diseases. In this article, we present composite iron oxide-gadolinium-containing Prussian blue nanoparticles (Fe3O4@GdPB) as a novel theranostic agent for T1-weighted magnetic resonance imaging (MRI) and photothermal therapy (PTT) of tumors. These particles combine the well-described properties and safety profiles of the constituent Fe3O4 nanoparticles and gadolinium-containing Prussian blue nanoparticles. The Fe3O4@GdPB nanoparticles function both as effective MRI contrast agents and PTT agents as determined by characterizing studies performed in vitro and retain their properties in the presence …


Prospective Evaluation Of The Influence Of Iterative Reconstruction On The Reproducibility Of Coronary Calcium Quantification In Reduced Radiation Dose 320 Detector Row Ct., Andrew D. Choi, Eric S Leifer, Jeannie Yu, Sujata M Shanbhag, Kathie Bronson, Andrew E Arai, Marcus Y Chen Jul 2016

Prospective Evaluation Of The Influence Of Iterative Reconstruction On The Reproducibility Of Coronary Calcium Quantification In Reduced Radiation Dose 320 Detector Row Ct., Andrew D. Choi, Eric S Leifer, Jeannie Yu, Sujata M Shanbhag, Kathie Bronson, Andrew E Arai, Marcus Y Chen

Radiology Faculty Publications

BACKGROUND: Coronary artery calcium (CAC) predicts coronary heart disease events and is important for individualized cardiac risk assessment. This report assesses the interscan variability of CT for coronary calcium quantification using image acquisition with standard and reduced radiation dose protocols and whether the use of reduced radiation dose acquisition with iterative reconstruction (IR; "reduced-dose/IR ") allows for similar image quality and reproducibility when compared to standard radiation dose acquisition with filtered back projection (FBP; "standard-dose/FBP") on 320-detector row computed tomography (320-CT).

METHODS: 200 consecutive patients (60 ± 9 years, 59% male) prospectively underwent two standard- and two reduced-dose acquisitions (800 …


Interrater Reliability Of Quantitative Ultrasound Using Force Feedback Among Examiners With Varied Levels Of Experience, Michael O. Harris-Love, Catheeja Ismail, Reza Monfaredi, Haniel J. Hernandez, Donte Pennington, Paula Woletz, Valerie Mcintosh, Bernadette Adams, Marc R. Blackman Jan 2016

Interrater Reliability Of Quantitative Ultrasound Using Force Feedback Among Examiners With Varied Levels Of Experience, Michael O. Harris-Love, Catheeja Ismail, Reza Monfaredi, Haniel J. Hernandez, Donte Pennington, Paula Woletz, Valerie Mcintosh, Bernadette Adams, Marc R. Blackman

Exercise and Nutrition Sciences Faculty Publications

Background. Quantitative ultrasound measures are influenced by multiple external factors including examiner scanning force. Force feedback may foster the acquisition of reliable morphometry measures under a variety of scanning conditions. The purpose of this study was to determine the reliability of force-feedback image acquisition and morphometry over a range of examiner-generated forces using a muscle tissuemimicking ultrasound phantom.

Methods. Sixty material thickness measures were acquired from a muscle tissue mimicking phantom using B-mode ultrasound scanning by six examiners with varied experience levels (i.e., experienced, intermediate, and novice). Estimates of interrater reliability and measurement error with force feedback scanning were determined …