Open Access. Powered by Scholars. Published by Universities.®

Radiation Medicine Commons

Open Access. Powered by Scholars. Published by Universities.®

Genetics and Genomics

Biodosimetry

Publication Year

Articles 1 - 3 of 3

Full-Text Articles in Radiation Medicine

Improved Radiation Expression Profiling In Blood By Sequential Application Of Sensitive And Specific Gene Signatures, Eliseos J. Mucaki, Ben C. Shirley, Peter K. Rogan Oct 2021

Improved Radiation Expression Profiling In Blood By Sequential Application Of Sensitive And Specific Gene Signatures, Eliseos J. Mucaki, Ben C. Shirley, Peter K. Rogan

Biochemistry Publications

Purpose. Combinations of expressed genes can discriminate radiation-exposed from normal control blood samples by machine learning based signatures (with 8 to 20% misclassification rates). These signatures can quantify therapeutically-relevant as well as accidental radiation exposures. The prodromal symptoms of Acute Radiation Syndrome (ARS) overlap those present in Influenza and Dengue Fever infections. Surprisingly, these human radiation signatures misclassified gene expression profiles of virally infected samples as false positive exposures. The present study investigates these and other confounders, and then mitigates their impact on signature accuracy.

Methods. This study investigated recall by previous and novel radiation signatures independently derived …


Estimating Partial Body Ionizing Radiation Exposure By Automated Cytogenetic Biodosimetry, Peter Rogan Sep 2020

Estimating Partial Body Ionizing Radiation Exposure By Automated Cytogenetic Biodosimetry, Peter Rogan

Biochemistry Publications

Purpose: Inhomogeneous exposures to ionizing radiation can be detected and quantified with the Dicentric Chromosome Assay (DCA) of metaphase cells. Complete automation of interpretation of the DCA for whole body irradiation has significantly improved throughput without compromising accuracy, however low levels of residual false positive dicentric chromosomes (DCs) have confounded its application for partial body exposure determination.

Materials and Methods: We describe a method of estimating and correcting for false positive DCs in digitally processed images of metaphase cells. Nearly all DCs detected in unirradiated calibration samples are introduced by digital image processing. DC frequencies of irradiated calibration …


Radiation Dose Estimation By Completely Automated Interpretation Of The Dicentric Chromosome Assay, Peter Rogan, Yanxin Li, Ben Shirley, Ruth Wilkins, Farrah Norton, Joan Knoll Jan 2019

Radiation Dose Estimation By Completely Automated Interpretation Of The Dicentric Chromosome Assay, Peter Rogan, Yanxin Li, Ben Shirley, Ruth Wilkins, Farrah Norton, Joan Knoll

Biochemistry Publications

Accuracy of the automated dicentric chromosome (DC) assay relies on metaphase image selection. This study validates a software framework to find the best image selection models that mitigate inter-sample variability. Evaluation methods to determine model quality include the Poisson goodness-of-fit of DC distributions for each sample, residuals after calibration curve fitting and leave-one-out dose estimation errors. The process iteratively searches a pool of selection model candidates by modifying statistical and filter cut-offs to rank the best candidates according to their respective evaluation scores. Evaluation scores minimize the sum of squared errors relative to the actual radiation dose of the calibration …