Open Access. Powered by Scholars. Published by Universities.®

Ophthalmology Commons

Open Access. Powered by Scholars. Published by Universities.®

University of Nebraska Medical Center

Optical Coherence

Publication Year

Articles 1 - 2 of 2

Full-Text Articles in Ophthalmology

Outcomes With As-Needed Ranibizumab After Initial Monthly Therapy: Long-Term Outcomes Of The Phase Iii Ride And Rise Trials., David S. Boyer, Quan Dong Nguyen, David M. Brown, Karen Basu, Jason S. Ehrlich Dec 2015

Outcomes With As-Needed Ranibizumab After Initial Monthly Therapy: Long-Term Outcomes Of The Phase Iii Ride And Rise Trials., David S. Boyer, Quan Dong Nguyen, David M. Brown, Karen Basu, Jason S. Ehrlich

Journal Articles: Ophthalmology

PURPOSE: To determine whether the efficacy and safety achieved with monthly ranibizumab as treatment for diabetic macular edema (DME) can be maintained with less-than-monthly treatment.

DESIGN: Open-label extension (OLE) phase of randomized, sham-controlled phase III trials: RIDE (NCT00473382) and RISE (NCT00473330).

PARTICIPANTS: Five hundred of 582 adults who completed the 36-month randomized core studies elected to enter the OLE.

METHODS: All patients participating in the OLE were eligible to receive 0.5 mg ranibizumab according to predefined re-treatment criteria: Treatment was administered when DME was identified by the investigator on optical coherence tomography or when best-corrected visual acuity (BCVA) worsened by …


Retina-Simulating Phantom For Optical Coherence Tomography., Jigesh Baxi, William Calhoun, Yasir Jamal Sepah, Daniel X. Hammer, Ilko Ilev, T. Joshua Pfefer, Quan Dong Nguyen, Anant Agrawal Feb 2014

Retina-Simulating Phantom For Optical Coherence Tomography., Jigesh Baxi, William Calhoun, Yasir Jamal Sepah, Daniel X. Hammer, Ilko Ilev, T. Joshua Pfefer, Quan Dong Nguyen, Anant Agrawal

Journal Articles: Ophthalmology

Optical coherence tomography (OCT) is a rapidly growing imaging modality, particularly in the field of ophthalmology. Accurate early diagnosis of diseases requires consistent and validated imaging performance. In contrast to more well-established medical imaging modalities, no standardized test methods currently exist for OCT quality assurance. We developed a retinal phantom which mimics the thickness and near-infrared optical properties of each anatomical retinal layer as well as the surface topography of the foveal pit. The fabrication process involves layer-by-layer spin coating of nanoparticle-embedded silicone films followed by laser micro-etching to modify the surface topography. The thickness of each layer and dimensions …