Open Access. Powered by Scholars. Published by Universities.®

Internal Medicine Commons

Open Access. Powered by Scholars. Published by Universities.®

Selected Works

Endobronchial valves

Articles 1 - 2 of 2

Full-Text Articles in Internal Medicine

Bronchopleural Fistula Resolution With Endobronchial Valve Placement And Liberation From Mechanical Ventilation In Acute Respiratory Distress Syndrome: A Case Series, Haris Kalatoudis, Nikhil Meena, Fuad Zeid, Yousef Shweihat Apr 2019

Bronchopleural Fistula Resolution With Endobronchial Valve Placement And Liberation From Mechanical Ventilation In Acute Respiratory Distress Syndrome: A Case Series, Haris Kalatoudis, Nikhil Meena, Fuad Zeid, Yousef Shweihat

Yousef R. Shweihat

Patients who have acute respiratory distress syndrome (ARDS) with persistent air leaks have worse outcomes. Endobronchial valves (EBV) are frequently deployed after pulmonary resection in noncritically ill patients to reduce and eliminate bronchopleural fistulas (BPFs) with persistent air leak (PAL). Information regarding EBV placement in mechanically ventilated patients with ARDS and high volume persistent air leaks is rare and limited to case reports. We describe three cases where EBV placement facilitated endotracheal extubation in patients with severe respiratory failure on prolonged mechanical ventilation with BPFs. In each case, EBV placement led to immediate resolution of PAL. We believe endobronchial valve …


Bronchopleural Fistula Resolution With Endobronchial Valve Placement And Liberation From Mechanical Ventilation In Acute Respiratory Distress Syndrome: A Case Series, Haris Kalatoudis, Nikhil Meena, Fuad Zeid, Yousef Shweihat Apr 2019

Bronchopleural Fistula Resolution With Endobronchial Valve Placement And Liberation From Mechanical Ventilation In Acute Respiratory Distress Syndrome: A Case Series, Haris Kalatoudis, Nikhil Meena, Fuad Zeid, Yousef Shweihat

Fuad M. Zeid

Patients who have acute respiratory distress syndrome (ARDS) with persistent air leaks have worse outcomes. Endobronchial valves (EBV) are frequently deployed after pulmonary resection in noncritically ill patients to reduce and eliminate bronchopleural fistulas (BPFs) with persistent air leak (PAL). Information regarding EBV placement in mechanically ventilated patients with ARDS and high volume persistent air leaks is rare and limited to case reports. We describe three cases where EBV placement facilitated endotracheal extubation in patients with severe respiratory failure on prolonged mechanical ventilation with BPFs. In each case, EBV placement led to immediate resolution of PAL. We believe endobronchial valve …