Open Access. Powered by Scholars. Published by Universities.®

Hepatology Commons

Open Access. Powered by Scholars. Published by Universities.®

Thomas Jefferson University

EUS

Publication Year

Articles 1 - 2 of 2

Full-Text Articles in Hepatology

A Multicenter Evaluation Of A New Eus Core Biopsy Needle: Experience In 200 Patients., Douglas G. Adler, V. Raman Muthusamy, Dean S. Ehrlich, Gulshan Parasher, Nirav C. Thosani, Ann Chen, Jonathan M. Buscaglia, Anoop Appannagari, Eduardo Quintero, Harry Aslanian, Linda Jo Taylor, Ali Siddiqui Mar 2019

A Multicenter Evaluation Of A New Eus Core Biopsy Needle: Experience In 200 Patients., Douglas G. Adler, V. Raman Muthusamy, Dean S. Ehrlich, Gulshan Parasher, Nirav C. Thosani, Ann Chen, Jonathan M. Buscaglia, Anoop Appannagari, Eduardo Quintero, Harry Aslanian, Linda Jo Taylor, Ali Siddiqui

Division of Gastroenterology and Hepatology Faculty Papers

Background and Objectives: We present a multicenter study of a new endoscopic ultrasound-guided fine-needle biopsy (EUS-FNB) needle (Acquire, Boston Scientific, Natick, MA). The aim of the study was to analyze the needle's clinical performance when sampling solid lesions and to assess the safety of this device.

Methods: We performed a multicenter retrospective study of patients undergoing EUS-FNB during July 1-November 15, 2016.

Results: Two hundred patients (121 males and 79 females) underwent EUS-FNB of solid lesions with the Acquire needle. Lesions included solid pancreatic masses (n = 109), adenopathy (n = 45), submucosal lesions (n = 34), cholangiocarcinoma (n = …


A Multicenter Comparative Trial Of A Novel Eus-Guided Core Biopsy Needle (Sharkcore, Mariam Naveed, Ali A. Siddiqui, Thomas E. Kowalski, David E. Loren, Ammara Khalid, Ayesha Soomro, Syed M. Mazhar, Joseph Yoo, Raza Hasan, Silpa Yalamanchili, Nicholas Tarangelo, Linda J. Taylor, Douglas G. Adler Jan 2018

A Multicenter Comparative Trial Of A Novel Eus-Guided Core Biopsy Needle (Sharkcore, Mariam Naveed, Ali A. Siddiqui, Thomas E. Kowalski, David E. Loren, Ammara Khalid, Ayesha Soomro, Syed M. Mazhar, Joseph Yoo, Raza Hasan, Silpa Yalamanchili, Nicholas Tarangelo, Linda J. Taylor, Douglas G. Adler

Division of Gastroenterology and Hepatology Faculty Papers

Background and Objectives: The ability to obtain adequate tissue of solid pancreatic lesions by EUS-guided remains a challenge. The aim of this study was to compare the performance characteristics and safety of EUS-FNA for evaluating solid pancreatic lesions using the standard 22-gauge needle versus a novel EUS biopsy needle.

Methods: This was a multicenter retrospective study of EUS-guided sampling of solid pancreatic lesions between 2009 and 2015. Patients underwent EUS-guided sampling with a 22-gauge SharkCore (SC) needle or a standard 22-gauge FNA needle. Technical success, performance characteristics of EUS-FNA, the number of needle passes required to obtain a diagnosis, diagnostic …