Open Access. Powered by Scholars. Published by Universities.®

Medical Biotechnology Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Medical Biotechnology

Development Of Hif-1Α/Hif-1Β Heterodimerization Inhibitors Using A Novel Bioluminescence Reporter Assay System For In Vitro High Throughput Screening And In Vivo Imaging, Yun-Chen Chiang Aug 2013

Development Of Hif-1Α/Hif-1Β Heterodimerization Inhibitors Using A Novel Bioluminescence Reporter Assay System For In Vitro High Throughput Screening And In Vivo Imaging, Yun-Chen Chiang

Dissertations & Theses (Open Access)

Tumor growth often outpaces its vascularization, leading to development of a hypoxic tumor microenvironment. In response, an intracellular hypoxia survival pathway is initiated by heterodimerization of hypoxia-inducible factor (HIF)-1α and HIF-1β, which subsequently upregulates the expression of several hypoxia-inducible genes, promotes cell survival and stimulates angiogenesis in the oxygen-deprived environment. Hypoxic tumor regions are often associated with resistance to various classes of radio- or chemotherapeutic agents. Therefore, development of HIF-1α/β heterodimerization inhibitors may provide a novel approach to anti-cancer therapy. To this end, a novel approach for imaging HIF-1α/β heterodimerization in vitro and in vivo was developed in this study …


Closed Loop Control Of A Cylindrical Tube Type Ionic Polymer Metal Composite (Ipmc), Benjamin Mead May 2013

Closed Loop Control Of A Cylindrical Tube Type Ionic Polymer Metal Composite (Ipmc), Benjamin Mead

UNLV Theses, Dissertations, Professional Papers, and Capstones

The goal of this research is to provide a framework for the integration of tube type, cylindrical Ionic Polymer Metal-Composite (IPMC) into conventional devices. IPMCs are one of the most widely used types of electro-active polymer actuator, due to their low electric driving potential and large deformation range. For this research a tube type IPMC was investigated. This IPMC has a circular cross section with four separate electrodes on its surface and a hole through the middle. The four electrodes allow for biaxial bending and accurate control of the tip location. One of the main advantages of using this type …


Attachment Ability And Melanoma Inhibitory Activity Mrna Expression Level Changes In Murine B16-F10 Melanoma Cells Post Nanosecond Electric Pulses, Hongxia Jia Jan 2013

Attachment Ability And Melanoma Inhibitory Activity Mrna Expression Level Changes In Murine B16-F10 Melanoma Cells Post Nanosecond Electric Pulses, Hongxia Jia

Theses and Dissertations in Biomedical Sciences

The effects of high-voltage nanosecond electric pulses (nsEPs) on metastatic melanoma are still unclear. Hence, we applied one, two, three, and four 300 ns 40 kV/cm pulses to murine B16-F10 melanoma cells. Cell attachment ability was determined by comparing the number of floating cells and the percentage of attached cells. Melanoma inhibitory activity (MIA) is a secretory protein that is highly correlated with the malignancy and metastasis of malignant melanomas. We used MIA as our target to evaluate the effect of nsEPs on metastasis. Pulsed (experimental) and unpulsed (control) cells were incubated at 37°C under a 5% CO2 atmosphere. …