Open Access. Powered by Scholars. Published by Universities.®

Pediatric Dentistry and Pedodontics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 8 of 8

Full-Text Articles in Pediatric Dentistry and Pedodontics

Success Of Early Childhood Caries After Treatment With Silver Diamine Fluoride Compared To Conventional Glass Ionomer Restoration. A Systematic Review, Sara H. Younis, Afnan M. Elkordy, Nouran M. Alshazly May 2024

Success Of Early Childhood Caries After Treatment With Silver Diamine Fluoride Compared To Conventional Glass Ionomer Restoration. A Systematic Review, Sara H. Younis, Afnan M. Elkordy, Nouran M. Alshazly

Future Dental Journal

Abstract

Aim: To compare the success rate regarding esthetics, parenteral satisfaction, and oral health related quality of life (OHRQoL) after treatment of early childhood caries with Silver Diamine Fluoride (SDF)compared to conventional Glass ionomer Restoration (CGI).

Materials and Methods: We conducted a systematic review following PRISMA statement by searching on the following electronic databases: PubMed, Cochrane.

Results: From the studies included in this systematic review, two studies showed significant difference in color stability between SDF and CGI. Two studies showed no significant difference in parental satisfaction with either SDF or Glass Ionomer. Regarding the Oral Health Related Quality of Life, …


Comparison Of Alignment Duration Between 0.018” And 0.022” Slot Brackets In Non-Extraction Orthodontic Adult Patients: (A Randomized Clinical Study), Omar Hazem Abouwafia, Hala Munir Abdel Majeed, Mona Salah Fayed, Nouran Fouad Seif-Eldin May 2024

Comparison Of Alignment Duration Between 0.018” And 0.022” Slot Brackets In Non-Extraction Orthodontic Adult Patients: (A Randomized Clinical Study), Omar Hazem Abouwafia, Hala Munir Abdel Majeed, Mona Salah Fayed, Nouran Fouad Seif-Eldin

Future Dental Journal

Abstract:

Introduction: Orthodontist tend to use one of the 2 bracket slot sizes available either the 0.018” or 0.022” bracket slot. Till now there is no reliable scientific evidence that indicates if any of them has a superior effect on the duration of teeth alignment. The aim of this study is to compare alignment duration between 0.018 and 0.022-inch bracket slot systems.

Subjects and methods: 14 Eligible participants having an age range of 14-22 years were randomly allocated to 2 groups (7 in each group). Group I: 0.018-inch and Group II: 0.022-inch slot (American orthodontics Mini master Roth prescription …


Comparison Between Orthodontic Measurements Taken From Cone-Beam Computed Tomography (Cbct) And Digital Models After Enmasse Retraction In Orthodontic Patients With Maxillary Protrusion., Amr M. Attia, Amr R. El-Beialy, Heba M. Dehis, Yehya A. Moustafa May 2024

Comparison Between Orthodontic Measurements Taken From Cone-Beam Computed Tomography (Cbct) And Digital Models After Enmasse Retraction In Orthodontic Patients With Maxillary Protrusion., Amr M. Attia, Amr R. El-Beialy, Heba M. Dehis, Yehya A. Moustafa

Future Dental Journal

ABSTRACT

Objectives: This study aimed to evaluate the accuracy and reliability in measuring anchorage loss, molar rotation, and total amount of retraction using cone beam computed tomography (CBCT) and to compare them with the same measurements obtained using digitally scanned dental models. Materials and methods: 24 patients requiring comprehensive orthodontic treatment including extraction of 1st premolars with maximum anchorage using enmasse retraction. CBCTs were undertaken on the same 24 patients using InVivoDental software for measurement. The digital cast was made using alginate impressions, from which virtual 3D models will be created and measured using 3Shape analyzer software. Orthodontic measurements will …


Measuring Accuracy Of Dolphin Imaging Software In Predicting Upper Jaw Soft Tissue Profile Changes In Class Ii Adult Patients Treated With Extraction Versus Non-Extraction., Amr Amin Arif, Esam Nasef, Amira Aboalnaga May 2024

Measuring Accuracy Of Dolphin Imaging Software In Predicting Upper Jaw Soft Tissue Profile Changes In Class Ii Adult Patients Treated With Extraction Versus Non-Extraction., Amr Amin Arif, Esam Nasef, Amira Aboalnaga

Future Dental Journal

Abstract

Objective: To assess the accuracy of Dolphin Imaging software in predicting upper jaw profile changes in class II patients treated by extraction and non-extraction.

Methods: The records of 60 Class II div 1 patients were selected; 30 patients treated by extraction of upper first premolar and 30 patients treated by non-extraction. The Pre- and post-treatment lateral cephalometric x-rays of each patient were traced using Dolphin software. The actual hard tissue changes due to treatment were calculated and installed into the prediction module to generate the predicted profile. The soft tissue measurements of the actual post-treatment and predicted profiles were …


Smear Layer Removal Using Two Different Ni-Ti Instruments With Two Different Irrigating Systems. An Invitro Study, Tasneem Mohamed Reyad, Wael Ahmed Hessein, Ahmed Abdelrahman Hashem Ah, Said Abd Elhafiz May 2024

Smear Layer Removal Using Two Different Ni-Ti Instruments With Two Different Irrigating Systems. An Invitro Study, Tasneem Mohamed Reyad, Wael Ahmed Hessein, Ahmed Abdelrahman Hashem Ah, Said Abd Elhafiz

Future Dental Journal

Objectives: To evaluate and compare smear layer removal in root canals instrumented with two single Ni-Ti rotary instruments with two different irrigating systems. Materials and Methods: Sixty recently extracted single-rooted mandibular premolars teeth were decoronated to a standardized length of 14 mm. Roots were divided into two main groups (n=30) according to the rotary NiTi file used for instrumentation either with One Shape (OS) file or with One Curve file (OC). Each main group was subdivided into three subgroups according to the methods used to agitate the irrigating solutions either sonically or ultrasonically as following: Group A was subdivided into …


Contents Of Vol. 31, No.1, April 2024, Yuniardini Septorini Wimardhani May 2024

Contents Of Vol. 31, No.1, April 2024, Yuniardini Septorini Wimardhani

Journal of Dentistry Indonesia

This is the Cover and the Contents of the Vol. 31 No. 1 2024


Epidemiology Of Bruxism And Temporomandibular Joint Disorders (Tmd) In Iranian Adults: A Cross-Sectional Study, Parviz Amini, Maryam Sharifi, Reyhane Aftabi, Fatemeh Jahanimoghadam, Hamidreza Jahanimoghadam Apr 2024

Epidemiology Of Bruxism And Temporomandibular Joint Disorders (Tmd) In Iranian Adults: A Cross-Sectional Study, Parviz Amini, Maryam Sharifi, Reyhane Aftabi, Fatemeh Jahanimoghadam, Hamidreza Jahanimoghadam

Journal of Dentistry Indonesia

Objective: The prevalence of bruxism in the literature has been reported differently. The aim of this study was to assess the prevalence of bruxism in patients aged 25–40 who were referred to Kerman Dental School. Methods: This analytical descriptive cross-sectional study was performed on 320 patients referred to the Department of Oral Medicine of Kerman Dentistry Faculty in the age range of 25 to 40 years old. The prevalence of bruxism as well as TMJ disorders were evaluated. Data were collected in a questionnaire and entered into SPSS version 24. Analyzing was done by a chi-square test at …


Effect Of Taper And Pitch On Nickle-Titanium File With Variable Cross Section To Its Cyclic Fatigue (In Silico Study), Yustika Chrysandra, Tunjung Nugraheni, Wignyo Hadriyanto Apr 2024

Effect Of Taper And Pitch On Nickle-Titanium File With Variable Cross Section To Its Cyclic Fatigue (In Silico Study), Yustika Chrysandra, Tunjung Nugraheni, Wignyo Hadriyanto

Journal of Dentistry Indonesia

The geometric design of an endodontic file includes cross-sectional shape, taper, and pitch. NiTi endodontic files of OneCurve (MicroMega) are made of two variations of cross-sectional shape, that is, double-s shaped and triple helix. Various kinds of modifications were made to increase the resistance of the NiTi endodontic files from fracture. Cyclic fatigue is the most common factor that causes a fracture of the endodontic file. Objective: The purpose of this study was to obtain a NiTi endodontic file design that has the best cyclic resistance value based on its taper size and number of pitch. Methods: This …