Catechol-Containing Copolymers As An Active Ingredient For Denture Adhesives, Vincent Ying Wun Kong Apr 2021

Catechol-Containing Copolymers As An Active Ingredient For Denture Adhesives, Vincent Ying Wun Kong

Electronic Thesis and Dissertation Repository

Moisture inside the mouth adds challenge to making denture adhesives formulations. Some formulations have zinc to enhance adhesion on wet skin despite knowing the health hazards. Inspired by mussel foot proteins’ catechol unit’s strong underwater adhesion, nine catechol-containing copolymers (P1A-P3C) were synthesized by free radical polymerization of 3,4-dimethoxystyrene (3,4- DMS) with different styrene derivatives followed by deprotection. P1A-P3C were used to make Fn(P)-C-PBS denture adhesive formulations which had suitable shear stresses around ≥ 5 kPa satisfying ISO 10873. In-situ NMR studies of free radical polymerization of 3,4 - DMS and styrene derivatives allowed computation of their reactivity ratios showing all …


A Critical Review And Finite Element Study Of Structural Relaxation In Veneered 3y-Tzp Dental Structures, Prashant S. Shelar Feb 2021

A Critical Review And Finite Element Study Of Structural Relaxation In Veneered 3y-Tzp Dental Structures, Prashant S. Shelar

Electronic Thesis and Dissertation Repository

Yttria stabilized Tetragonal Zirconia Polycrystal (3Y-TZP) materials veneered with porcelain are preferred for clinical practice due to their bio-functionality, biocompatibility, and affordability. However, these materials are often subjected to premature clinical failures due to combination of subsurface flaws and tensile stresses within porcelains. This work focuses on performing a critical literature review and evaluating veneer characteristics, i.e. structural relaxation, to form a suitable explanation for the development of subsurface stresses. User material subroutines, UEXPAN and UTRS are developed, validated and integrated in ABAQUS finite element solver. With the use of validated models, it is shown that faster cooling rates and …


Accuracy Of Digital Impressions At Varying Implant Depths: An In-Vitro Study, Vivia Sequeira Jan 2021

Accuracy Of Digital Impressions At Varying Implant Depths: An In-Vitro Study, Vivia Sequeira

Graduate Theses, Dissertations, and Problem Reports

Introduction: Implants placed at variable depths may vary the amount of visible scannable surface of a scan body. Intraoral scanner technology uses advanced optical principles to record the surface of the scan body to accurately capture the implant position.

Purpose: To investigate the effect implant placement depth has on the accuracy of digital implant impressions using an intraoral scanner.

Materials & Methods: A partially edentulous gypsum master model was fabricated to allow the positioning of a single implant analog at different depths. Four groups based on the planned implant depths of 0, 3, 6 and 7mm and corresponding visibility of …


Clinical Accuracy Between Planned And Placed Posterior Implant Position Of Two Static Implant Planning Software Programs In Inexperienced Operators, Wanwanat Singthong Jan 2021

Clinical Accuracy Between Planned And Placed Posterior Implant Position Of Two Static Implant Planning Software Programs In Inexperienced Operators, Wanwanat Singthong

Chulalongkorn University Theses and Dissertations (Chula ETD)

Objective: This study aimed to evaluate and examine the difference in posterior implant positioning between the planned and placed positions when inexperienced operators used two static implant planning software packages following a fully guided implant surgery protocol in the clinical field. Materials and methods: Twenty-four patients who needed single posterior implant placement were randomly divided into two groups based on the used implant planning software (group 1, coDiagnostiX, n=12; group 2, Implant Studio, n=12). The dataset of the placed implant position, generated from digitizing the implant impression, was superimposed on the planned implant position. The number of horizontal, angular, and …


Accuracy Comparison Of Dental Implants Obtained By Dynamic Cais In All-On-4 Edentulous Area Among Different Types Of Bone Density: An In Vitro Study, Jutasinee Pornpolsarun Jan 2021

Accuracy Comparison Of Dental Implants Obtained By Dynamic Cais In All-On-4 Edentulous Area Among Different Types Of Bone Density: An In Vitro Study, Jutasinee Pornpolsarun

Chulalongkorn University Theses and Dissertations (Chula ETD)

Background: Determination of available bone is particularly important in implant placement quality of bone can affect the accuracy implant placement. Currently, Dynamic navigation system illustrated the improvement of implant accuracy, The accuracy of implant placement using computer-assisted implant placement system (CAIS) is unknown. As a result, the goal of this study was to see how bone density affected implant placement accuracy with Dynamic CAIS. Purpose: To determine the effect of different bone density in the accuracy of implant placement using dynamic navigation system Materials and Methods: The study's overall design includes a single doctor planning each implant using a CBCT …


A Comparison Of Implant Stability Between Two Dental Implant Designusing Two Different Stability Measuring Technique, Chanikarn Chaksupa Jan 2021

A Comparison Of Implant Stability Between Two Dental Implant Designusing Two Different Stability Measuring Technique, Chanikarn Chaksupa

Chulalongkorn University Theses and Dissertations (Chula ETD)

Objective To investigate the primary stability of aggressive thread design implant comparing to nonaggressive thread design implant and to evaluate the correlation between ISQ values and IST values. Materials and methods 96 implants were used in this study. 48 BLT Straumann® and 48 BLX Straumann® were used. All implants were digitally planned and placed in 3D printed model using computer assisted guided surgery. The edentulous area at models were packed with randomized pattern of four different kinds of polyurethane blocks to replicate mixed cancellous bone. Postoperative implant stability measurement was performed immediately after implant insertion. Implant stability was measured by …


The Relative Occlusal Force Of Natural Tooth Adjacent To Distal Extension Implant Support Fixed Prosthesis Using T-Scan Analysis : A Cross Sectional Study, Chin Purintarapiban Jan 2021

The Relative Occlusal Force Of Natural Tooth Adjacent To Distal Extension Implant Support Fixed Prosthesis Using T-Scan Analysis : A Cross Sectional Study, Chin Purintarapiban

Chulalongkorn University Theses and Dissertations (Chula ETD)

Objective: This cross-sectional study aimed to compare the relative occlusal force between implant in the distal end and tooth adjacent to implant in maximum intercuspation. Methodology: Patients with implant restoration replacing teeth in free end space adjacent to natural tooth were recalled. The occlusion is examined as shim stock passes through the occluded tooth in heavy or light bites. The heavy bite or a light bite with shim stock that cannot pull through is HB1 or LB1. If the shim stock can pull through it is considered HB0 or LB0. The implant is classified into 3 groups, HB1LB0, HB1LB1, and …


A Comparison Of Implant Stability Between Two Implant Systems Using Guided Surgery In Inexperienced Surgeons, Pinmuk Supachaiyakit Jan 2021

A Comparison Of Implant Stability Between Two Implant Systems Using Guided Surgery In Inexperienced Surgeons, Pinmuk Supachaiyakit

Chulalongkorn University Theses and Dissertations (Chula ETD)

Aim: To investigate the implant stability in relation to two different implant designs, a cylindrical shaped single threaded design (CS/ST) and a tapered shaped double threaded design (TS/DT) using RFA over the first 8 weeks. Materials and Methods: 28 implants were randomly allocated into two groups and were placed as single tooth implant in the posterior arch. CBCT scan was used to determine the bone density and the implants were placed with guided surgical template by inexperienced surgeons which were prepared with the same implant planning software. The implant stability was measured using the RFA over the first 8 weeks …