Open Access. Powered by Scholars. Published by Universities.®

Dental Materials Commons

Open Access. Powered by Scholars. Published by Universities.®

Theses/Dissertations

Multivariate Analysis

Articles 1 - 9 of 9

Full-Text Articles in Dental Materials

Comparison Of Microleakage In Three Sealant Placement Protocols Vs. The Enamel Loc System, Audrey T. Sheu Jun 2008

Comparison Of Microleakage In Three Sealant Placement Protocols Vs. The Enamel Loc System, Audrey T. Sheu

Loma Linda University Electronic Theses, Dissertations & Projects

PURPOSE: To evaluate sealant microleakage using four different application techniques.

METHODS: The four application techniques evaluated were acid etch only, Adper L-Pop bonding, Optibond bonding, and Enamel Loc One-Step Sealant. Sixty-four extracted third molar teeth were assigned on one of four application techniques (n=16) and Clinpro sealants applied according to the manufacturer's instructions. The teeth were thermocycled for 500 cycles, dyed, and embedded in resin. The samples were then sectioned and evaluated for microleakage on the buccal and lingual surfaces. Statistical methods employed to analyze the data were the Kruskal-Willis rank test and the Mann-Whitney U test.

RESULTS: No significant …


Effect Of Gutta Percha On The Retention Of A Post Using Different Cements, Saeda H. Basta Jun 2008

Effect Of Gutta Percha On The Retention Of A Post Using Different Cements, Saeda H. Basta

Loma Linda University Electronic Theses, Dissertations & Projects

This study evaluated the effect of residual gutta percha on the retention strength of prefabricated post cemented with four different cements. Forty intact mandibular single canal canines or premolars were selected for standardized size and quality, endodontically treated, and decoronated to the cementoenamel junction. A post space was prepared to accommodate Para post XP size 4 (Coltene, Whaledent Inc., Cuy Falls, Ohio) to a depth of 8 mm. The Obtura heated gutta percha system was used to inject a very thin line of gutta percha along one lateral wall to the depth of the future post. Forty obturated teeth were …


Comparison Of Laser And Phosphoric Acid Etching On Sealant Shear Bond Strength, Seth David Latimer Jun 2007

Comparison Of Laser And Phosphoric Acid Etching On Sealant Shear Bond Strength, Seth David Latimer

Loma Linda University Electronic Theses, Dissertations & Projects

PURPOSE: To compare the effect of traditional phosphoric acid etching with Er,Cr:YSGG laser enamel etching on the shear bond strength of sealant material.

METHODS: Extracted healthy third molars were mounted in acrylic exposing the flattest surface available. Three groups of twenty teeth were used to evaluate traditional acid etching with 37% phosphoric acid as a control group as well as two different laser settings. The sealant material was attached using specialized jigs and then subjected to shear bond strength testing utilizing the ultradent method (MTS machine). Statistical methods employed were the Kruskal-Wallis rank test and the Mann-Whitney U test.

RESULTS: …


The Effect Of Calcium Hydroxide Pastes On Root Dentin Fracture Resistance, Kurt W. Sturz Jun 2006

The Effect Of Calcium Hydroxide Pastes On Root Dentin Fracture Resistance, Kurt W. Sturz

Loma Linda University Electronic Theses, Dissertations & Projects

Calcium hydroxide is a common intracanal medicament used in the treatment of immature teeth that have been subjected to trauma or decay prior to root canal therapy. The effect of calcium hydroxide on immature root dentin is important. One area of concern is the effect that calcium hydroxide has on the fracture resistance of an immature tooth. It is the aim of this study to compare the effect of four different commercially available calcium hydroxide pastes on the fracture resistance of bovine teeth. Seventy-five freshly extracted, intact bovine incisors were prepared according to a modified Haapasalo and Orstavik technique. Each …


The Outcome Of Mta As A Root End Filling Material: A Long Term Evaluation, Christopher M. Sechrist Sep 2005

The Outcome Of Mta As A Root End Filling Material: A Long Term Evaluation, Christopher M. Sechrist

Loma Linda University Electronic Theses, Dissertations & Projects

Periradicular surgery is a viable option to save natural teeth when non-surgical treatment fails or when endodontic retreatment is not feasible or contraindicated. Laboratory and animal studies have demonstrated that MTA is biocompatible, provides an excellent seal against penetrating bacteria, and promotes hard tissue healing. The purpose of this study was to provide long term (>3 years) clinical evidence for its use as a root-end filling material in endodontics. The clinical records of 294 patients who had MTA used during endodontic treatment from 1996 to 2001 were reviewed. From these, 75 patients whose root end cavities had been filled …


The Effect Of Naocl, Ca(Oh)2, Mta And Mtad On Root Dentin Fracture Resistance, Sunil Ilapogu Dec 2004

The Effect Of Naocl, Ca(Oh)2, Mta And Mtad On Root Dentin Fracture Resistance, Sunil Ilapogu

Loma Linda University Electronic Theses, Dissertations & Projects

Various materials are used for the treatment of immature teeth that have been subjected to trauma or decay. It is not well established what effect these materials may have on the immature root dentin. A concern would be the resistance to fracture of the remaining root dentin. The purpose of this study was to compare the resistance of fracture of bovine teeth treated with sodium hypochlorite, calcium hydroxide, gray MTA and gray MTA in conjunction with MTAD after certain periods of time. One hundred and ninety five freshly extracted, intact bovine incisors were prepared using a modified Haapasalo and Orstavik …


Comparison Of Bracket Bond Strength By Total, Self-Etch And Laser Treatment, Kyo Sung Shawn Kim Dec 2003

Comparison Of Bracket Bond Strength By Total, Self-Etch And Laser Treatment, Kyo Sung Shawn Kim

Loma Linda University Electronic Theses, Dissertations & Projects

Laser etching of enamel surfaces alters the physical and chemical characteristics of the enamel. These changes in characteristics enhance the bonding to enamel. The purpose of this study was to compare the shear and tensile bond strength of Er,Cr:YSGG hydrokinetic laser system (Biolase) with 37% phosphoric acid and self etching primer 30 minutes and 72 hours after bonding. Four different laser power output setting was observed: 1.5W, 2.0W, 2.5W, and 3.0W. Two hundred forty bovine teeth free of defect, caries, and dentin exposure were mounted in acrylic resin and divided into 24 groups of 10 teeth. Sixteen groups of 10 …


A Bond Strength Comparison Of Led And Halogen Light Curing Units, John Richard Kavanagh Dec 2003

A Bond Strength Comparison Of Led And Halogen Light Curing Units, John Richard Kavanagh

Loma Linda University Electronic Theses, Dissertations & Projects

The purpose of this research was to compare the tensile bond strength of orthodontic flat based buttons bonded to bovine teeth with four commercial light-emitting diode (LED) curing lights and one conventional quartz tungsten halogen (QTH) curing light.

The dental market has recently been introduced to a number of commercially available light-emitting diode (LED) curing lights. Tensile bond strength was evaluated for LED curing lights (Rembrandt® AllegroTM, Den-Mat Corp, Santa Maria, CA), (LEDemetron, Kerr/Demetron Corp, Danbury, Conn), (Ortholux LED, 3MTMESPETM, St. Paul, MN),and (FLASH-lite 1001, Discus Dental, Culver City, CA) are compared with one …


The Radiopacity Of 29 Resin Restorative Materials Compared To Enamel, Peter Lubisich Iv Sep 2003

The Radiopacity Of 29 Resin Restorative Materials Compared To Enamel, Peter Lubisich Iv

Loma Linda University Electronic Theses, Dissertations & Projects

The radiodensity of a composite resin can greatly influence a clinician's ability to analyze a restoration for failure. The purpose of this study was to determine the relative radiopacities of 29 resin restorative materials compared to enamel, and to verify the comparable radiopacity between shades of 23 of the restorative composite resin materials. Composite resin discs measuring >5mm in diameter and 2 mm in thickness were made and polymerized. Radiographs were taken of the composite resin discs, which included an aluminum step wedge for calibration and a densitometer was used to measure the radiodensity of the composite resin samples. The …