Open Access. Powered by Scholars. Published by Universities.®

Dental Materials Commons

Open Access. Powered by Scholars. Published by Universities.®

Theses/Dissertations

Design of Experiments and Sample Surveys

Articles 1 - 5 of 5

Full-Text Articles in Dental Materials

Immediate Loading Of Unsplinted Implants In The Anterior Mandible For Overdentures, Phillip Roe Mar 2009

Immediate Loading Of Unsplinted Implants In The Anterior Mandible For Overdentures, Phillip Roe

Loma Linda University Electronic Theses, Dissertations & Projects

In this one-year prospective study, eight completely edentulous patients were selected from the Loma Linda University School of Dentistry (LLUSD) patient population to participate. There were five male and three female patients, between the ages of 58 and 82 (mean age of 69.1 years). All participants received new maxillary and mandibular complete dentures prior to implant placement. Two 4.0 mm x 13 mm threaded implants with a fluoride-modified, micro-roughened, titanium surface were placed mesial to each mandibular canine position. Locator abutments were connected and torqued to 25 Ncm and primary closure was achieved with a nonresorbable suture material. The Locator …


The Effect Of Calcium Hydroxide Pastes On Root Dentin Fracture Resistance, Kurt W. Sturz Jun 2006

The Effect Of Calcium Hydroxide Pastes On Root Dentin Fracture Resistance, Kurt W. Sturz

Loma Linda University Electronic Theses, Dissertations & Projects

Calcium hydroxide is a common intracanal medicament used in the treatment of immature teeth that have been subjected to trauma or decay prior to root canal therapy. The effect of calcium hydroxide on immature root dentin is important. One area of concern is the effect that calcium hydroxide has on the fracture resistance of an immature tooth. It is the aim of this study to compare the effect of four different commercially available calcium hydroxide pastes on the fracture resistance of bovine teeth. Seventy-five freshly extracted, intact bovine incisors were prepared according to a modified Haapasalo and Orstavik technique. Each …


The Fracture Strength Of Ceramic Brackets : An Update And Comparison, Christian P. Manley Jun 1991

The Fracture Strength Of Ceramic Brackets : An Update And Comparison, Christian P. Manley

Loma Linda University Electronic Theses, Dissertations & Projects

The purpose of this study was to compare the fracture strength of ceramic brackets which are currently on the market with ceramic brackets tested in a previous study at Loma Linda. Fracture strengths of standard edgewise ceramic brackets vs. pre-torqued ceramic brackets and bicuspid ceramic brackets vs. central incisor ceramic brackets were also compared.

A total of 160 Polycrystalline brackets, 8 categories in groups if 20, were tested for fracture strength. Each bracket was tested using the same testing model that was used in the previous study at Loma Linda. The brackets were tested by torquing a wire within the …


Methodology In Measurement Of Load Loss Or Gain In Orthodontic Wires : A Pilot Study, Merton S. Lacy Jun 1980

Methodology In Measurement Of Load Loss Or Gain In Orthodontic Wires : A Pilot Study, Merton S. Lacy

Loma Linda University Electronic Theses, Dissertations & Projects

The purpose of this investigation was to develop methods and equipment to measure and record over any desired length of time the loss or gain in force of any material used in orthodontics that can produce a force upon an object. The material and the object being acted upon should not be disturbed while measuring that force.

Holding devices were designed and constructed in two basic forms. For intrusive and extrusive type forces, a load cell was fixed horizontally in such a position that an adjustable tube with a set screw to hold the wire could be rotated to cause …


Fatigue Properties Of Orthodontic Wire, Kirkland B. Reuer Jun 1979

Fatigue Properties Of Orthodontic Wire, Kirkland B. Reuer

Loma Linda University Electronic Theses, Dissertations & Projects

Fracture of orthodontic appliances can be a problem because of the time involved to replace and repair them. It has been shown that most failures have been a result of fatigue fracture, i.e., failure resulting from cyclic loading.

The purpose of this study was to determine what effect variation of the type of orthodontic wire and heat treatment had on fatigue resistance. A device was constructed to put a cyclic load on a piece of wire until fracture. Two types of cobalt-chromium alloy wire (Blue and Green Elgiloy from Rocky Mountain Orthodontics) and three types of stain less steel wire …