Oral Wellness: Using Occupational Therapy To Enhance Oral Hygiene Delivery In Long-Term Care, Lauryn J. Banovitz, Liberty Bellah, Rosemarie Lion May 2015

Oral Wellness: Using Occupational Therapy To Enhance Oral Hygiene Delivery In Long-Term Care, Lauryn J. Banovitz, Liberty Bellah, Rosemarie Lion

Dissertations, Masters Theses, Capstones, and Culminating Projects

Based on current literature, oral health in long-term care (LTC) facilities is frequently of low priority and does not follow evidence-based best practices. Poor oral health reduces the quality of life of older adult residents and patients and can lead to systemic diseases, such as cardiovascular disease, stroke, and pneumonia, the leading cause of death in LTC. Occupational therapists can play an instrumental role as oral care consultants, and educators, and can act as resource guides to raise the standards of oral care in LTC facilities.

This capstone project explored ways in which occupational therapy, a profession traditionally designated for …


Work Of Fracture In Ceramic Bracket Bonding Systems, Tye A. Roylance Sep 2010

Work Of Fracture In Ceramic Bracket Bonding Systems, Tye A. Roylance

Loma Linda University Electronic Theses, Dissertations & Projects

Introduction: Work of fracture (WOE) is a method of analysis of the toughness or resilience of a bracket bonding system. It is an indication of a bracket bonding systems ability to withstand forces in the mouth below the force at which failure occurs. Work of fracture gives an indication of how much abuse the bracket/bonding system can withstand and still maintain an adequate adhesion to the tooth surface. This analysis incorporates shear bond strength and displacement and is determined in part by the elasticity and resilience of the specimen being studied.

Materials and Methods: One hundred and eighty bovine teeth …


Comparison Of Microleakage In Three Sealant Placement Protocols Vs. The Enamel Loc System, Audrey T. Sheu Jun 2008

Comparison Of Microleakage In Three Sealant Placement Protocols Vs. The Enamel Loc System, Audrey T. Sheu

Loma Linda University Electronic Theses, Dissertations & Projects

PURPOSE: To evaluate sealant microleakage using four different application techniques.

METHODS: The four application techniques evaluated were acid etch only, Adper L-Pop bonding, Optibond bonding, and Enamel Loc One-Step Sealant. Sixty-four extracted third molar teeth were assigned on one of four application techniques (n=16) and Clinpro sealants applied according to the manufacturer's instructions. The teeth were thermocycled for 500 cycles, dyed, and embedded in resin. The samples were then sectioned and evaluated for microleakage on the buccal and lingual surfaces. Statistical methods employed to analyze the data were the Kruskal-Willis rank test and the Mann-Whitney U test.

RESULTS: No significant …


Immediate Provionalization Of Single Threaded Oxidized Implants On Maxillary Premolars Healed Sites: One-Year Study, Kiyotaka Umezu Jun 2008

Immediate Provionalization Of Single Threaded Oxidized Implants On Maxillary Premolars Healed Sites: One-Year Study, Kiyotaka Umezu

Loma Linda University Electronic Theses, Dissertations & Projects

Osseointegrated endosseous implants have been widely used and become a predictable treatment option for completely and partially edentulous patients. The viability and predictability of this treatment modality have been supported with the high success rates in numerous studies. Clinical guideline requires a healing period of 3 to 6 months without functional loading to achieve osseointegration with machine surface implants. Therefore, numerous studies on immediately loaded implants have been conducted in an attempt to minimize or eliminate this healing period. The purpose of this study was to evaluate the success rate of the immediately provisionalized oxidized-surface implants in healed sites supporting …


Comparison Of Laser And Phosphoric Acid Etching On Sealant Shear Bond Strength, Seth David Latimer Jun 2007

Comparison Of Laser And Phosphoric Acid Etching On Sealant Shear Bond Strength, Seth David Latimer

Loma Linda University Electronic Theses, Dissertations & Projects

PURPOSE: To compare the effect of traditional phosphoric acid etching with Er,Cr:YSGG laser enamel etching on the shear bond strength of sealant material.

METHODS: Extracted healthy third molars were mounted in acrylic exposing the flattest surface available. Three groups of twenty teeth were used to evaluate traditional acid etching with 37% phosphoric acid as a control group as well as two different laser settings. The sealant material was attached using specialized jigs and then subjected to shear bond strength testing utilizing the ultradent method (MTS machine). Statistical methods employed were the Kruskal-Wallis rank test and the Mann-Whitney U test.

RESULTS: …


Bone Morphogenic Protein Induced Repair Of The Premaxillary Cleft, Rick J. Rawson Jun 2006

Bone Morphogenic Protein Induced Repair Of The Premaxillary Cleft, Rick J. Rawson

Loma Linda University Electronic Theses, Dissertations & Projects

The purpose of this study is to evaluate the bony augmentation of premaxillary clefts in humans using recombinant bone morphogenic protein (rhBMP-2) in a collagen sponge carrier. 12 patients with unilateral cleft alveolar ridges were evaluated pre- and 4 months postoperatively. 10 patients were repaired with rhBMP-2 while two others were grafted with anterior iliac crest particulate marrow cancellous bone (PMCB). Computed tomographic studies were used to evaluate preoperative alveolar cleft volumes, postoperative bone bridge volumes, and pre/post operative volume ratios.

A pre/post operative volume ratio for patients repaired with rhBMP-2 ranged from 24.1% to 90.6% with a mean of …


De-Bonding 4 Brands Of Ceramic Brackets With The Waterlase Er,Cr;Ysgg Laser, Carter A. Lane Sep 2005

De-Bonding 4 Brands Of Ceramic Brackets With The Waterlase Er,Cr;Ysgg Laser, Carter A. Lane

Loma Linda University Electronic Theses, Dissertations & Projects

The purpose of this study was to determine if the Biolase Waterlase Er,Cr:YSGG laser could be used as a safe and effective tool to de-bond four currently available orthodontic ceramic brackets. Changes in interpulpal temperature, enamel surface conditions and the amount of time the laser was activated to debond (sic) the ceramic brackets were evaluated. Forty human maxillary premolars were divided into four groups of ten. Prior to direct bonding, all extracted teeth were impressed and duplicated in Araldite epoxy resin as the control surface. Identical techniques were used to bond 10 ceramic brackets from each manufacturer. Three of the …


Resonance Frequency Analysis As A Determinant Of Implant Initial Stability, Negar Tabandeh Jun 2005

Resonance Frequency Analysis As A Determinant Of Implant Initial Stability, Negar Tabandeh

Loma Linda University Electronic Theses, Dissertations & Projects

Introduction: The clinicians' decision regarding immediate loading is largely determined by the assessment of initial stability of the dental implant. Computed tomographic assessment of recipient site bone quality, insertion resistance torque and post-insertion resonance frequency are currently the only objective methods of measurement establishing initial stability.

Purpose: A study was designed to measure resonance frequency of root form dental implants placed in cadaver jaws. The resonance frequency values were compared to previous subjective and objective data reported in prior studies in the series.

Materials and Methods: Resonance frequency measurements were secured using the Osstell ™ mentor unit on 4.0 X …


Comparison Of Bracket Bond Strength By Total, Self-Etch And Laser Treatment, Kyo Sung Shawn Kim Dec 2003

Comparison Of Bracket Bond Strength By Total, Self-Etch And Laser Treatment, Kyo Sung Shawn Kim

Loma Linda University Electronic Theses, Dissertations & Projects

Laser etching of enamel surfaces alters the physical and chemical characteristics of the enamel. These changes in characteristics enhance the bonding to enamel. The purpose of this study was to compare the shear and tensile bond strength of Er,Cr:YSGG hydrokinetic laser system (Biolase) with 37% phosphoric acid and self etching primer 30 minutes and 72 hours after bonding. Four different laser power output setting was observed: 1.5W, 2.0W, 2.5W, and 3.0W. Two hundred forty bovine teeth free of defect, caries, and dentin exposure were mounted in acrylic resin and divided into 24 groups of 10 teeth. Sixteen groups of 10 …


The Radiopacity Of 29 Resin Restorative Materials Compared To Enamel, Peter Lubisich Iv Sep 2003

The Radiopacity Of 29 Resin Restorative Materials Compared To Enamel, Peter Lubisich Iv

Loma Linda University Electronic Theses, Dissertations & Projects

The radiodensity of a composite resin can greatly influence a clinician's ability to analyze a restoration for failure. The purpose of this study was to determine the relative radiopacities of 29 resin restorative materials compared to enamel, and to verify the comparable radiopacity between shades of 23 of the restorative composite resin materials. Composite resin discs measuring >5mm in diameter and 2 mm in thickness were made and polymerized. Radiographs were taken of the composite resin discs, which included an aluminum step wedge for calibration and a densitometer was used to measure the radiodensity of the composite resin samples. The …


Effects Of Mtad On Some Physical Properties Of Enamel And Dentin, Tanya Kristina Machnick Jun 2003

Effects Of Mtad On Some Physical Properties Of Enamel And Dentin, Tanya Kristina Machnick

Loma Linda University Electronic Theses, Dissertations & Projects

Recently, a Mixture of Tetracycline, an Acid, and a Detergent (MTAD) has been advocated to remove smear layer and disinfect canals. The purpose of this study was to evaluate the effect of MTAD the flexural strength and modulus of elasticity of dentin as well as its effect on the bond strength to enamel and dentin. In Part I, dentin bars were randomly assigned to eight groups treated either with various concentrations of NaOCl (5.25%, 2.65%, 1.31%, 0.66%), 17% EDTA, MTAD, saline, or according to a clinical protocol with 1.3% NaOCl and then 5 min of MTAD. …


Bond Strengths Of Three Orthodontic Adhesives For Direct And Indirect Bonding, Aaron Rondon Aug 2002

Bond Strengths Of Three Orthodontic Adhesives For Direct And Indirect Bonding, Aaron Rondon

Loma Linda University Electronic Theses, Dissertations & Projects

The technique of bonding orthodontic brackets utilizing a transfer tray, otherwise known as indirect bonding, is a dichotomous subject. It allows for more accurate bracket placement and reduced chair time for the patient and doctor, yet its technique sensitivity can yield bracket failures at the time of tray removal. With the recent development of 3M's Sondhi Rapid Set, an adhesive specifically designed for orthodontic bonding, the purpose of this study was to compare this fairly new indirect adhesive with 3M's Transbond XT and Reliance's Rely-A-Bond.

Two hundred and seventy freshly extracted bovine teeth were mounted in acrylic resin and divided …


Patient Satisfaction And Effectiveness Of A New Resin Used To Bumper Orthodontic Brackets, Timothy B. Elison Aug 2002

Patient Satisfaction And Effectiveness Of A New Resin Used To Bumper Orthodontic Brackets, Timothy B. Elison

Loma Linda University Electronic Theses, Dissertations & Projects

Fear of pain is a key factor in discouraging patients from seeking orthodontic treatment, with many patients discontinuing treatment due to pain experienced in the early stages of treatment. Patients often complain of traumatized lips and buccal mucosa, which is usually caused by the brackets. Orthodontists try to minimize this pain and discomfort by using bumpering materials. Although wax is the most commonly used product, there are many bracket bumpering materials available.

The purpose of this study was to evaluate the clinical effectiveness and patient comfort/satisfaction of a new flowable resin, Ortho Shield, designed to protect the lips and …


Failure Mode Of An Orthodontic Resin Alone And With Bonded Brackets, Marc Cody Dunn Jun 2000

Failure Mode Of An Orthodontic Resin Alone And With Bonded Brackets, Marc Cody Dunn

Loma Linda University Electronic Theses, Dissertations & Projects

Since the introduction of bonded orthodontic brackets in the early 1960's spontaneous debonding has been a constant nemesis. Most attempts to avoid this problem by orthodontic manufactures have focused on "bond strength" issue. Whether they chose to address the materials, the bracket base or both, the common method used to evaluate improvements entailed the use of just one testing apparatus: a static universal testing machine such as the Instron.

Metal, ceramic and plastic bonded brackets were tested with the traditional shear/peel method as well as a new high strain rate impact test. The resin itself was also evaluated for physical …


Clinical Debonding Simulation Study Of One Metal And Two Ceramic Brackets, Hyunsup Shim Sep 1999

Clinical Debonding Simulation Study Of One Metal And Two Ceramic Brackets, Hyunsup Shim

Loma Linda University Electronic Theses, Dissertations & Projects

The purpose of this study is to compare two mechanical debonding methods on ceramic brackets (TP MXi and 3M Clarity) and a metal bracket (GAC OmniArch) with four different bonding materials (light-cured, one-step chemical-cured, two-step chemical-cured, and Fuji GIC) in clinical simulation, where the diametral force was applied on the handle of the pliers. The effectiveness of mechanical debonding technique was determined by evaluating the following variables: the amount of force required to debond the bracket, the amount of residual adhesive remaining on the enamel surface, the frequency of unexpected bracket failure, and the prevalence of visible enamel damage. The …


Mutagenecity Of Formocresol, Glutaraldehyde, Ferric Sulfate And Aluminum Chloride : Materials Used In Therapeutic Pulpotomies, Adolfo Barrera Jun 1996

Mutagenecity Of Formocresol, Glutaraldehyde, Ferric Sulfate And Aluminum Chloride : Materials Used In Therapeutic Pulpotomies, Adolfo Barrera

Loma Linda University Electronic Theses, Dissertations & Projects

Ferric sulfate (Astringedent) and aluminum chloride (Hemodent) have been proposed as possible medicaments for use in primary teeth for therapeutic pulpotomies.

There is little information in the literature about the biologic properties of these medicaments.

The purpose of this study was to evaluate the mutagenic response of the ferric sulfate and aluminum chloride and compare them with glutaraldehyde (1.5%, 1% and 0.5% concentration) and formocresol (2%, 0.75%, 0.01% and 0.005% concentration). TA98 and TA1535 strain were used in the Ames test to assess mutagenecity. Neither ferric sulfate nor aluminum chloride exhibited mutagenic potential, in comparison with glutaraldehyde and formocresol, which …


The Effects Of Rapid Palatal Expansion Therapy On The Periodontal Tissues Of The Central Incisors, Richard Gutierrez Jun 1995

The Effects Of Rapid Palatal Expansion Therapy On The Periodontal Tissues Of The Central Incisors, Richard Gutierrez

Loma Linda University Electronic Theses, Dissertations & Projects

The periodontal structures around the maxillary central incisors in thirty-nine post-orthodontically treated patients, twenty-five of these patients had experienced Rapid Palatal Expansion (RPE), were examined to determine the periodontal consequences associated with two ways of managing the resultant diastema. In fourteen patients the diastema closure was assisted by elastomeric chain and in eleven patients the diastema closure was not assisted. Fourteen non-RPE orthodontically treated patients served as controls. Height of attached gingiva, gingival sulcus depth, attachment level, and alveolar bone level were recorded. One examiner, using calibrated techniques, performed all the measurements. The RPE groups and the control group all …


A Pilot Study Comparing The Forces Applied : Using A Chin Cup And Three Types Of Protraction Headgear, Daniel Miles Beisiegel Dec 1994

A Pilot Study Comparing The Forces Applied : Using A Chin Cup And Three Types Of Protraction Headgear, Daniel Miles Beisiegel

Loma Linda University Electronic Theses, Dissertations & Projects

A pilot study comparing force distributions of a chin cup, the Great Lakes reverse pull headgear (RPHG), Ormco's adjustable dynamic RPHG, and Grummons RPHG was done. A skull from a 69 year old female which demonstrated a Class III malocclusion was used to perform the tests of force. Forces applied to and generated on the skull were measured using a water-filled balloon system. This method was tested and found to be reliable and accurate.

Repeated measurements of force were recorded for each of the areas of stress (forehead, cheeks, chin, and condyles, as well as the posterior and superior portions …


Load Deformation Test Of Mini Twin Metal Brackets : A Comparative Study, Karl D. Peach Jun 1994

Load Deformation Test Of Mini Twin Metal Brackets : A Comparative Study, Karl D. Peach

Loma Linda University Electronic Theses, Dissertations & Projects

The trend toward more esthetic brackets has led to smaller brackets being used by orthodontists. The purpose of this study was to determine the force required to deform these smaller brackets and calculate the stress in the metal by using a torsional wire bending force. Ten types of brackets were tested and the results analyzed to determine how bracket geometry, manufacturing method, or material selection affected the strength of brackets. Results showed a significant difference between manufacturing methods, material used, and bracket geometry. Brackets made of 17-4 PH SS and 303 SS withstood higher stress than 316 SS, and all …


An In Vitro Quantitative Evaluation And Comparison Of A Custom And A Popular Stock Orthodontic Appliance, Richard Scott Anderw Schalo Jun 1994

An In Vitro Quantitative Evaluation And Comparison Of A Custom And A Popular Stock Orthodontic Appliance, Richard Scott Anderw Schalo

Loma Linda University Electronic Theses, Dissertations & Projects

An in vitro performance evaluation and comparison of a patient individualized appliance (Elan, Ormco Corporation, Glendora, California) and a Roth prescription appliance ("A"- Company, San Diego, California) was made using the Ideal Tooth Relationship Index (ITRI).

The sample consisted of 19 duplicated sets of models for a total sample of 38. For each pair of models one set was bonded with an Elan appliance and a duplicated set was bonded with a Roth appliance. Bracket placement followed the manufacturers recommendations. The bracketed teeth from these models were sectioned out individually and the appliances allowed to fully express themselves on full …


The Fracture Strength Of Ceramic Brackets : An Update And Comparison, Christian P. Manley Jun 1991

The Fracture Strength Of Ceramic Brackets : An Update And Comparison, Christian P. Manley

Loma Linda University Electronic Theses, Dissertations & Projects

The purpose of this study was to compare the fracture strength of ceramic brackets which are currently on the market with ceramic brackets tested in a previous study at Loma Linda. Fracture strengths of standard edgewise ceramic brackets vs. pre-torqued ceramic brackets and bicuspid ceramic brackets vs. central incisor ceramic brackets were also compared.

A total of 160 Polycrystalline brackets, 8 categories in groups if 20, were tested for fracture strength. Each bracket was tested using the same testing model that was used in the previous study at Loma Linda. The brackets were tested by torquing a wire within the …


A Comparison Of Enamel Detachments After Debonding Between Unitek's "Dynalok" Bracket And A Foil-Mesh Bracket: A Scanning Electron Microscope Study, Robert E. Meister Aug 1984

A Comparison Of Enamel Detachments After Debonding Between Unitek's "Dynalok" Bracket And A Foil-Mesh Bracket: A Scanning Electron Microscope Study, Robert E. Meister

Loma Linda University Electronic Theses, Dissertations & Projects

The intent of this paper was to: 1. Evaluate the mode of adhesive failure when debonding both flexible and rigid base orthodontic brackets. 2. Evaluate the bracket bases for enamel detachments. 3. Measure the enamel detachments.

After preforming shear test on flexible and rigid base orthodontic brackets mounted to extracted human teeth it was determined that failure occurred at the enamel/adhesive interface 30% of the time, at the bracket/adhesive interface 10% of the time and a combination of these 60% of the time for both groups.

Five brackets from each group were evaluated for enamel detachments using energy dispersive x-ray …


A Comparison Of Two Rapid Palatal Expansion Appliances And Their Effect On Palatal Cross-Sectional Area, William D. Scott Jun 1982

A Comparison Of Two Rapid Palatal Expansion Appliances And Their Effect On Palatal Cross-Sectional Area, William D. Scott

Loma Linda University Electronic Theses, Dissertations & Projects

Two rapid palatal expansion appliances, acrylic-free and acrylic-reinforced, were compared for their effect on the cross-sectional area of the palate. Two groups, twenty-five patients in each, were selected so that they would match as closely as possible with regards to age and sex distribution. The pre-treatment and post-treatment maxillary models were duplicated, and this duplicate model was then trimmed in a specific manner to allow the cross-sectional area between the first permanent molars to be compared. The results indicate that there is no difference, at the five percent level of significance, between these two appliances. It is concluded that the …


Force Loss In Retraction Springs At 37°C As Affected By Time, Roger Edward Clawson Feb 1982

Force Loss In Retraction Springs At 37°C As Affected By Time, Roger Edward Clawson

Loma Linda University Electronic Theses, Dissertations & Projects

Closed helix retraction springs fabricated from .016 X .016 inch Blue Elgiloy, Permachrome Standard stain less steel, and Multiphase orthodontic wire were tested at 37°C in their heat and nonheat treated condition to determine force relaxation properties. Electronic equipment consisting of load cells, regulated power supply, and an automatic recording device were used to measure force changes which occurred in the wire samples over a seven day period. A constant temperature was maintained by an ethylene glycol and water circulator. A temperature probe and an electronic thermometer monitored the 37°C water bath surrounding the wire samples. The data was graphed …


A Comparative Study Of Tensile Properties In Five Orthodontic Wires, Charles B. Mcdermott Jun 1981

A Comparative Study Of Tensile Properties In Five Orthodontic Wires, Charles B. Mcdermott

Loma Linda University Electronic Theses, Dissertations & Projects

The tensile properties of .017 x .025" stainless steel. Multiphase, Blue Elgiloy, beta titanium, and Nitinol were tested and compared. All wires were tested in the "as received" condition. Fifteen samples of each type of wire were tested in order to determine the (1) modulus of elasticity, (2) .2% yield strength, (3) ultimate tensile strength, (4) percentage elongation and (5) maximum elastic deflection.

The modulus of elasticity and .2% yield strength are the most important properties to orthodontists because of their influence on the wire's stiffness, strength and range. The ratio of yield strength/modulus of elasticity, termed maximum elastic deflection, …


Methodology In Measurement Of Load Loss Or Gain In Orthodontic Wires : A Pilot Study, Merton S. Lacy Jun 1980

Methodology In Measurement Of Load Loss Or Gain In Orthodontic Wires : A Pilot Study, Merton S. Lacy

Loma Linda University Electronic Theses, Dissertations & Projects

The purpose of this investigation was to develop methods and equipment to measure and record over any desired length of time the loss or gain in force of any material used in orthodontics that can produce a force upon an object. The material and the object being acted upon should not be disturbed while measuring that force.

Holding devices were designed and constructed in two basic forms. For intrusive and extrusive type forces, a load cell was fixed horizontally in such a position that an adjustable tube with a set screw to hold the wire could be rotated to cause …


Fatigue Properties Of Orthodontic Wire, Kirkland B. Reuer Jun 1979

Fatigue Properties Of Orthodontic Wire, Kirkland B. Reuer

Loma Linda University Electronic Theses, Dissertations & Projects

Fracture of orthodontic appliances can be a problem because of the time involved to replace and repair them. It has been shown that most failures have been a result of fatigue fracture, i.e., failure resulting from cyclic loading.

The purpose of this study was to determine what effect variation of the type of orthodontic wire and heat treatment had on fatigue resistance. A device was constructed to put a cyclic load on a piece of wire until fracture. Two types of cobalt-chromium alloy wire (Blue and Green Elgiloy from Rocky Mountain Orthodontics) and three types of stain less steel wire …


The Development Of A New Appliance For The Third Stage Of Begg Treatment, Ronald C. Parker May 1973

The Development Of A New Appliance For The Third Stage Of Begg Treatment, Ronald C. Parker

Loma Linda University Electronic Theses, Dissertations & Projects

The third stage of Begg treatment can pose difficulties to the orthodontist. Some of the undesirable developments encountered are anchorage loss, unintentional tooth tipping, extrusion, intrusion, palatal and mandibular rotation, muscular strain and profile deficiency or procumbency. In the interest of eliminating or minimizing these developments a new appliance was developed for use during the third stage of treatment.

Simply described, the appliance consisted of a rigid vestibular arch that provided anchorage for flexible extensions to each tooth. Extraoral force was directed to the maxillary rigid arch to counter anterior root torquing forces.

Anchorage control, maxillary incisor torquing efficiency and …


Endodontic Sealing Properties Of Cavit, Chloro-Rosin Gutta Percha, N2, And Silver Cones Using Radioisotopes, Frank H. Beal May 1972

Endodontic Sealing Properties Of Cavit, Chloro-Rosin Gutta Percha, N2, And Silver Cones Using Radioisotopes, Frank H. Beal

Loma Linda University Electronic Theses, Dissertations & Projects

The main purpose of this investigation was to test the endodontic sealing abilities of silver cones, N2, warm gutta percha, chemically softened gutta percha, laterally condensed gutta percha and Cavit under carefully controlled conditions. Evaluations were done by radiographic, macroscopic, microscopic, and autoradiographic examinations.

The four points which must be considered when evaluating the efficacy of sealing root canal systems, in vivo, were presented and discussed.

Cavit as a total endodontic filling material was presented, investigated and discussed.

An improvement of the chloro-rosin - gutta percha diffusion technique was presented.

The concept of surface as well as marginal leakage was …


A Clinical Evaluation Of A Technique Utilizing Plastic Modules For Cuspid And Incisor Retraction, Dwane I. Johnston May 1972

A Clinical Evaluation Of A Technique Utilizing Plastic Modules For Cuspid And Incisor Retraction, Dwane I. Johnston

Loma Linda University Electronic Theses, Dissertations & Projects

In a clinical study, polyurethane-type plastic modules were evaluated for use in retracting cuspids and incisors in Class I extraction cases.

Seven patients were selected to be treated with a technique utilizing these plastic modules. All cases were in Class I molar relationship and were either bimaxillary, protrusive or had tooth-size, arch-length discrepancies.

Evaluation was based on rate of cuspid and incisor retraction and the control of molar anchorage during the retraction phase.

At four-week intervals data were collected on space closure. At the same time, such subjective data as amount and duration of pain, difficulty of appliance adjustment and …