Open Access. Powered by Scholars. Published by Universities.®

Dental Materials Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 5 of 5

Full-Text Articles in Dental Materials

Thermomechanical Characterization Of Variable Force Niti Orthodontic Archwires, Anjali Sudershan Krishan Mehta Jul 2015

Thermomechanical Characterization Of Variable Force Niti Orthodontic Archwires, Anjali Sudershan Krishan Mehta

Master's Theses (2009 -)

ABSTRACT THERMOMECHANICAL CHARACTERIZATION OF VARIABLE FORCE NITI ORTHODONTIC ARCHWIRES Anjali Mehta, BDS MDS Marquette University, 2015 Introduction: Nickel-Titanium (NiTi) archwires, due to their properties of superelasticity and shape memory, have been extensively used in orthodontic mechanotherapy. However, one of the shortcomings of these wires is that they deliver constant forces across the entire arch. The amount of force needed to move a tooth is a function of the surface area of the tooth and its supporting bone; and is lesser for single rooted anterior teeth compared to larger molars. The introduction of heat treatment of NiTi wires and the influence …


Influence Of Fluoride And Stress On The Mechanical Properties Of Nickel-Titanium Coils, Jennifer Ann Fehrman Roloff Jul 2015

Influence Of Fluoride And Stress On The Mechanical Properties Of Nickel-Titanium Coils, Jennifer Ann Fehrman Roloff

Master's Theses (2009 -)

Objective: The objective of this study was to determine the influence of fluoride and stress on the mechanical properties of nickel-titanium open coil springs. Materials and Methods: Sentalloy nickel-titanium open coil springs (15 mm length) were divided into five groups. A control group was tested mechanically in as-received condition. The other four experimental groups were exposed to artificial saliva (Fusayama-Meyer solution) at 37oC for 12 weeks in a 2x2 factorial design with fluoride exposure and stress (compression) as the two factors. Those springs which were under compression were held at 5 mm in length for the entirety of the testing …


Changes In Composite Toxicity Following Exposure To Pulp Capping Materials, Audra Long Jul 2015

Changes In Composite Toxicity Following Exposure To Pulp Capping Materials, Audra Long

Master's Theses (2009 -)

Introduction: Direct pulp capping involves placing a material over the exposed pulp in order to maintain its vitality. For decades, calcium hydroxide (CH) has served as the gold standard for this purpose, but its toxicity to the pulp may negatively impact treatment outcomes. Mineral Trioxide Aggregate (MTA) has become a popular alternative based partly on its excellent biocompatibility. Pulp-capped teeth are often restored with highly toxic composite materials, but the pulp capping material’s ability to alter these toxic effects has never been investigated. The purpose of this in vitro study is to determine the effects of Dycal, a CH-based cement, …


Influence Of Fluoride And Stress On The Electrochemical Properties Of Nickel-Titanium Coils, Ashley Barnes Jul 2015

Influence Of Fluoride And Stress On The Electrochemical Properties Of Nickel-Titanium Coils, Ashley Barnes

Master's Theses (2009 -)

The aim of this study was to examine the effects of fluoride and stress on the electrochemical properties of nickel-titanium coils. Forty Dentsply GAC NiTi coils were divided into four groups of ten and individually tested. Twenty coils were placed in a solution of artificial saliva, where ten of the twenty were compressed and the other ten were not stressed. The other twenty coils were placed in a 1500 ppm NaF solution, where ten were compressed and ten were not. The coils were connected to a computer driven potentiostat and three tests were conducted: open circuit potential monitoring for 2 …


Mechanical Properties And Patient Perceptions Of Commonly Used Clear Aligner Systems As-Received And After Clinical Use, Lauren Evan Montoure Teske Jul 2015

Mechanical Properties And Patient Perceptions Of Commonly Used Clear Aligner Systems As-Received And After Clinical Use, Lauren Evan Montoure Teske

Master's Theses (2009 -)

Background/Objectives: This study aimed to investigate the viscoelastic properties of two clear aligner systems, Invisalign (Align Technology, Inc, Santa Clara, CA, USA) and Simpli5 (Allesee Orthodontic Appliances, Sturtevant, WI, USA), and determine if there was a difference after use. A survey assessed patients’ perceptions of the aligner material and post-treatment satisfaction. Materials/Methods: Mandibular aligners were collected from two patients after 2-3 weeks of use (n=6). Duplicate, unused aligners were obtained for each patient (n=6). Dynamic mechanical analysis (DMA) characterized the viscoelastic properties of the materials. Three tests were done on separate specimens: frequency scan (0.1-10 Hz under 25 μm displacement …