A Comparison Of Enamel Detachments After Debonding Between Unitek's "Dynalok" Bracket And A Foil-Mesh Bracket: A Scanning Electron Microscope Study, Robert E. Meister Aug 1984

A Comparison Of Enamel Detachments After Debonding Between Unitek's "Dynalok" Bracket And A Foil-Mesh Bracket: A Scanning Electron Microscope Study, Robert E. Meister

Loma Linda University Electronic Theses, Dissertations & Projects

The intent of this paper was to: 1. Evaluate the mode of adhesive failure when debonding both flexible and rigid base orthodontic brackets. 2. Evaluate the bracket bases for enamel detachments. 3. Measure the enamel detachments.

After preforming shear test on flexible and rigid base orthodontic brackets mounted to extracted human teeth it was determined that failure occurred at the enamel/adhesive interface 30% of the time, at the bracket/adhesive interface 10% of the time and a combination of these 60% of the time for both groups.

Five brackets from each group were evaluated for enamel detachments using energy dispersive x-ray …