Articles 1 - 7 of 7

Full-Text Articles in Anatomy

An Investigation On The Influences Of Radial Head Hemiarthroplasty Stem Fixation Techniques On Articular Mechanics, Jakub Szmit Nov 2020

An Investigation On The Influences Of Radial Head Hemiarthroplasty Stem Fixation Techniques On Articular Mechanics, Jakub Szmit

Electronic Thesis and Dissertation Repository

Radial head hemiarthroplasty design has been extensively studied with a focus on utilizing the geometrical characteristics of the native radial dish as a guide of implant placement and design. Although implant design has been studied, optimal radial head implant fixation technique remains unknown. This thesis focused on the effect of stem fit on radiocapitellar contact mechanics, using both finite element and experimental bench-top approaches. Additionally, investigation into the impact of varus/valgus malalignment of the radial head in both the native state and following hemiarthroplasty was conducted. It was found that loose fitting a smooth stem axisymmetric radial head implant through …


The Of Application Of 3d-Printing To Lumbar Spine Surgery, Andrew J. Kanawati Apr 2020

The Of Application Of 3d-Printing To Lumbar Spine Surgery, Andrew J. Kanawati

Electronic Thesis and Dissertation Repository

Rapid prototyping refers to the manufacturing process in which a three-dimensional (3D) digital model can be transformed into a physical model by layering material in the shape of successive cross sections atop of previously layers. Rapid prototyping has been increasing in popularity in the field of medicine and surgery due to the ability to personalize various aspects of patient care. The thesis will explore the use of rapid prototyping in lumbar spine surgery, aim to quantify the accuracy of medical imaging when relating to imaged structures and their corresponding models produced by rapid prototyping, and determine if complex patient-specific guides …


Improving Material Mapping In Glenohumeral Finite Element Models: A Multi-Level Evaluation, Nikolas K. Knowles Apr 2019

Improving Material Mapping In Glenohumeral Finite Element Models: A Multi-Level Evaluation, Nikolas K. Knowles

Electronic Thesis and Dissertation Repository

An improved understanding of glenohumeral bone mechanics can be elucidated using computational models derived from computed tomography data. Although computational tools, such as finite element analysis, provide a powerful quantitative technique to evaluate and answer a variety of biomechanical and clinical questions, glenohumeral finite element models (FEMs) have not kept pace with improvements in modeling techniques or model validation methods seen in other anatomic locations. The present work describes the use of multi-level computational modeling to compare, develop and validate FEMs of the glenohumeral joint.

Common density-modulus relationships within the literature were evaluated using a multi-level comparative testing methodology to …


Acromial Insufficiency Fractures In Reverse Total Shoulder Arthroplasty: A Biomechanical Study, Alicia Kerrigan Dec 2018

Acromial Insufficiency Fractures In Reverse Total Shoulder Arthroplasty: A Biomechanical Study, Alicia Kerrigan

Electronic Thesis and Dissertation Repository

Reverse total shoulder arthroplasty (RTSA) is increasingly utilized in the aging population, with a growing list of surgical indications including rotator cuff tear arthropathy, proximal humerus fractures, and revision arthroplasty. Acromial insufficiency fractures following RTSA are poorly understood, difficult to diagnose, and associated with inferior clinical outcomes. There is limited knowledge in the literature regarding the etiology of post-operative acromial fractures. The purpose of this study is to evaluate the role of implant parameters on acromial strain following RTSA.

Using a cadaveric model, a custom designed modular RTSA system was implanted that allowed for evaluation of modifiable parameters including glenoid …


Tibiotalar Arthrodesis: Development Of A Novel Jig And Alignment Guide, Adam Mathew Ropchan Nov 2018

Tibiotalar Arthrodesis: Development Of A Novel Jig And Alignment Guide, Adam Mathew Ropchan

Electronic Thesis and Dissertation Repository

Tibiotalar arthrodesis is a surgical procedure, used for the treatment of end-stage ankle arthrosis and instability. There are dozens of described procedures in the literature, all with varying rates of success. Two of the most common reasons for reoperation in tibiotalar arthrodesis are nonunion and infection; few studies have established any associations between patient/surgical factors and reoperation for nonunion and infection.

The first part of this thesis focuses on determining the rate of reoperation to the ipsilateral lower limb and if any patient/surgical factors are associated with reoperation for nonunion and infection. The second part of this thesis turns attention …


Markerless Radiostereogammetry Of The Shoulder Joint In Humans: Comparisons Of Scapulohumeral Kinematics Between Individuals With Healthy And Supraspinatus-Impaired Shoulders, Ashley N. Hannon Apr 2016

Markerless Radiostereogammetry Of The Shoulder Joint In Humans: Comparisons Of Scapulohumeral Kinematics Between Individuals With Healthy And Supraspinatus-Impaired Shoulders, Ashley N. Hannon

Electronic Thesis and Dissertation Repository

The purpose of this collection of studies was to further develop the knowledge of shoulder motion in order to better understand joint function through direct measurement of 3D scapulohumeral joint kinematics using a technique of high accuracy. Markerless, bi-planar fluoroscopic radiostereometric analysis using a generic shoulder model was developed in this thesis, reducing the amount of radiation exposure to subjects. The studies compared kinematic data of the scapulohumeral joint in six degrees of freedom with a precise, in-vivo measuring technique. Data were collected on young and older healthy individuals, individuals with a torn supraspinatus and post-surgical intervention.

Although this generic …


Development And Assessment Of An Impact Apparatus And High-Speed Camera Motion Tracking System To Quantify The Effect Of Static Muscle Loads On Fracture Threshold Measures In The Distal Radius, Jacob M. Reeves Aug 2013

Development And Assessment Of An Impact Apparatus And High-Speed Camera Motion Tracking System To Quantify The Effect Of Static Muscle Loads On Fracture Threshold Measures In The Distal Radius, Jacob M. Reeves

Electronic Thesis and Dissertation Repository

Distal radius fractures are prevalent, debilitating, and costly. This thesis conducts an in vitro investigation of these injuries, examining the role of static muscle loading on fracture threshold measures (i.e., force, impulse, energy). Initially, an impact apparatus and custom LabVIEW colour-thresholding program were designed and assessed for repeatability and accuracy in quantifying fracture measures and impact kinematics. These tools were then used to test six pairs of cadaveric forearms, with static muscle loads simulated in one specimen from each pair. Distal radius fractures were achieved in 5 pairs, with perilunate dislocations in the remaining pair. None of the …