Open Access. Powered by Scholars. Published by Universities.®

Medical Specialties

Cardiac Catheterization

Publication Year

Articles 1 - 2 of 2

Full-Text Articles in Surgical Procedures, Operative

Speckle-Tracking Echocardiographic Measures Of Right Ventricular Function Correlate With Improvement In Exercise Function After Percutaneous Pulmonary Valve Implantation., Shahryar M. Chowdhury, Ziyad M. Hijazi, John T. Fahey, John F. Rhodes, Saibal Kar, Raj Makkar, Michael Mullen, Qi-Ling Cao, Girish S. Shirali Sep 2015

Speckle-Tracking Echocardiographic Measures Of Right Ventricular Function Correlate With Improvement In Exercise Function After Percutaneous Pulmonary Valve Implantation., Shahryar M. Chowdhury, Ziyad M. Hijazi, John T. Fahey, John F. Rhodes, Saibal Kar, Raj Makkar, Michael Mullen, Qi-Ling Cao, Girish S. Shirali

Manuscripts, Articles, Book Chapters and Other Papers

BACKGROUND: Speckle-tracking echocardiographic (STE) measures of right ventricular (RV) function appear to improve after transcatheter pulmonary valve implantation (TPVI). Measures of exercise function, such as ventilatory efficiency (the minute ventilation [VE]/carbon dioxide production [VCO2] slope), have been shown to be prognostic of mortality in patients who may require TPVI. The aim of this study was to evaluate the correlation between STE measures of RV function and changes in VE/VCO2 after TPVI.

METHODS: Speckle-tracking echocardiography and cardiopulmonary exercise testing were performed at baseline and 6 months after TPVI in 24 patients from four centers. Conventional echocardiographic measures of RV function were …


Percutaneous Implantation Of The Edwards Sapien Transcatheter Heart Valve For Conduit Failure In The Pulmonary Position: Early Phase 1 Results From An International Multicenter Clinical Trial., Damien Kenny, Ziyad M. Hijazi, Saibal Kar, John Rhodes, Michael Mullen, Raj Makkar, Girish S. Shirali, Mark Fogel, John Fahey, Mary G. Heitschmidt, Christopher Cain Nov 2011

Percutaneous Implantation Of The Edwards Sapien Transcatheter Heart Valve For Conduit Failure In The Pulmonary Position: Early Phase 1 Results From An International Multicenter Clinical Trial., Damien Kenny, Ziyad M. Hijazi, Saibal Kar, John Rhodes, Michael Mullen, Raj Makkar, Girish S. Shirali, Mark Fogel, John Fahey, Mary G. Heitschmidt, Christopher Cain

Manuscripts, Articles, Book Chapters and Other Papers

OBJECTIVES: The purpose of this study was to evaluate the safety and effectiveness of the Edwards SAPIEN transcatheter heart valve (Edwards Lifesciences LLC, Irvine, California) in the pulmonary position in patients with moderate to severe pulmonary regurgitation with or without stenosis.

BACKGROUND: Transcatheter pulmonary valve replacement is evolving, but to date, experience has been limited to the Melody valve (Medtronic Inc., Minneapolis, Minnesota).

METHODS: Eligible patients with dysfunctional right ventricle-to-pulmonary artery conduits were screened if body weight was ≥35 kg and the in situ conduit diameter was ≥16 mm and ≤24 mm. Standardized implantation and follow-up protocols were used.

RESULTS: …