Fire And Life Safety Report- Battalion Headquarters Complex (Ueph), Mathew Mershimer Jun 2015

Fire And Life Safety Report- Battalion Headquarters Complex (Ueph), Mathew Mershimer

Fire Protection Engineering: Culminating Experience Project Reports

This fire and life safety report covers a Battalion Headquarters Complex that is used for housing military troops. This is a complete review of the building with prescriptive based fire protection along with performance base review of the building. The prescriptive fire protection covers egress analysis of the space, passive fire protection (i.e. fire walls and doors) and active fire protection (i.e. fire alarm and fire sprinklers). The performance based section looks at the prescriptive requirements and sees if these would be enough for the application at hand. The building fire protection and life safety are covered by three different …


Fire And Life Safety Evaluation & Analysis- Bonderson Engineering Projects Center, Garrett Brown Mar 2015

Fire And Life Safety Evaluation & Analysis- Bonderson Engineering Projects Center, Garrett Brown

Fire Protection Engineering: Culminating Experience Project Reports

A Fire and Life Safety Analysis of the Bonderson Engineering Projects Center, (BEPC) Building 197 on the California Polytechnic State University, San Luis Obispo (Cal Poly) Campus is performed. Both prescriptive and performance based methods and metrics are utilized to evaluate the facility with respect to current fire and building standards and codes. Prescriptive fire protection features and systems analyzed include: building construction type and design, structural fire protection features and requirements, occupancy classification and egress analysis, fire detection, alarm, and communication systems, and fire suppression systems The prescriptive based design requirements largely met the code and installation requirements with …


Culminating Project Report- Warren J. Baker Center For Science And Mathematics, Blake Johnson Mar 2015

Culminating Project Report- Warren J. Baker Center For Science And Mathematics, Blake Johnson

Fire Protection Engineering: Culminating Experience Project Reports

This report analyzes the fire protection features of the Warren J. Baker Center for Science and Mathematics on the Cal Poly San Luis Obispo campus in San Luis Obispo, CA. The prescriptive analysis of the structural fire protection, egress, fire suppression, and fire alarm, detection, and communication systems shows that the building meets the requirements of current codes and standards. The performance based analysis includes simulating design fire scenarios in the atrium using computer modeling (CFAST, FDS) and the results of these models show that the atrium meets the tenability criterion for the calculated evacuation time of occupants.


Fire And Life Safety Analysis- Building 310- The Landing, Tyler Paller Mar 2015

Fire And Life Safety Analysis- Building 310- The Landing, Tyler Paller

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this report is to analyze Building 310 with regards to fire and life safety. Analysis was done both prescriptively and from a performance based design standpoint. The prescriptive based analysis includes review of the building’s design with regards to egress, fire alarm systems, suppression systems, and structural fire protection. The building was reviewed against current NFPA codes and the International Building Code to examine compliance. The performance-based analysis consists of two different fire scenarios that were examined. The goal was to show that the building met safety criteria and does not pose undue risk to occupants. This …


Fire Protection And Life Safety Engineering Analysis- Center For Science And Mathematics, Orelvis Gonzalez Cruz Mar 2015

Fire Protection And Life Safety Engineering Analysis- Center For Science And Mathematics, Orelvis Gonzalez Cruz

Fire Protection Engineering: Culminating Experience Project Reports

The Life Safety and Fire Protection systems in Cal Poly’s Center for Science and Mathematics (CSM) were analyzed and evaluated in this project, according to the requirements of the applicable codes and pertinent standards. The evaluation was conducted through a prescriptive-based approach, in conjunction with a performance-based approach. On one hand, the prescriptive-based approach considered the analysis of the Structural Fire Protection and Means of Egress in the building and the existing Fire Detection/Alarm and Fire Suppression Systems. On the other hand, the performance-based approach included an Egress Analysis, which assessed the Required Safe Egress Time (RSET) and the Available …


Solar Energy Research Center- Lawrence Berkeley National Laboratory!, Shellie Prescott Mar 2015

Solar Energy Research Center- Lawrence Berkeley National Laboratory!, Shellie Prescott

Fire Protection Engineering: Culminating Experience Project Reports

This report covers both a prescriptive and performance-based review of fire and life safety systems for the Solar Energy Research Center at the Lawrence Berkeley National Laboratory. The primary subjects covered are egress, fire alarm systems, and sprinkler systems. A unique feature and focal point for this report is the SERC east exit stair. This stair was originally designed as a glass atrium, but for various reasons cannot be utilized as an atrium. The east exit stair has a special VESDA detection system, is the most remote location for the sprinkler system, and is a primary exit for all three …


Construction Warehouse, Ben Johnson Jun 2014

Construction Warehouse, Ben Johnson

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this report is to provide a comprehensive evaluation of the fire protection and life safety design of a warehouse building that serves a large construction project. The results and conclusions from this evaluation are documented herein and supported by analysis when necessary. The gross floor area per story of the construction warehouse is 39,000 ft2. This building is used as a warehousing facility in support of a large construction project. Rack storage of Group A plastics is permitted in this facility to a height of 20 ft. beneath a 24 ft. ceiling on the main floor. Shelf …


Fire Protection Analysis Robert And Margrit Modavi Center For The Performing Arts- Uc Davis, Jeffrey Paterson Jun 2014

Fire Protection Analysis Robert And Margrit Modavi Center For The Performing Arts- Uc Davis, Jeffrey Paterson

Fire Protection Engineering: Culminating Experience Project Reports

This document is the report of the culminating experience as part of the master’s program in fire protection engineering at the California Polytechnic State University, San Luis Obispo. This report contains a life safety analysis of the fire protection systems of a chosen project building. The building examined is the Robert and Margrit Mondavi Center for the Performing Arts, located on the University of California Davis campus. The building was constructed in 2002 where the first performance occurred in October 2002. A large portion of the report applies prescriptive code requirements to evaluate compliance with current codes and standards. The …


Hotel- Georgia, Rock Toler Jun 2014

Hotel- Georgia, Rock Toler

Fire Protection Engineering: Culminating Experience Project Reports

The State of Georgia modifies the International Building Code through State amendments, to require a fire resistance rating between residential occupancies and all other occupancies. This fire and life safety analysis report will substantiate the necessity for the barrier in a mixed-use hotel occupancy. The first-half of the report addresses the prescriptive-based code requirements, reporting a compliant design was presented. Then the performance portions primary objective was established, maintain a tenable environment for egressing guest room occupants. Three conditions were evaluated to define a tenable environment, carbon monoxide levels, temperature, and visibility limits. Selecting the location of the fire required …


Fire And Life Safety Analysis- Uw Medicine Lake Union Phase 3.1, Marge Hong Jun 2014

Fire And Life Safety Analysis- Uw Medicine Lake Union Phase 3.1, Marge Hong

Fire Protection Engineering: Culminating Experience Project Reports

This report provides a summary of the fire protection and life safety features for UW Medicine Lake Union, a research and laboratory building, in accordance with Seattle Building Code (SBC), International Building Code (IBC), and Life Safety Code (NFPA 101). The objective of this report is to identify if UW Medicine Lake Union meets both the prescriptive and performance based code. The primary fire safety goal is to provide life safety system that reduced the risk of fire-related injuries and loss of life due to fire. The prescriptive analysis is used to identify the building integrity per code. This evaluates …


Westside Christian High School, Michael Stewart Jun 2014

Westside Christian High School, Michael Stewart

Fire Protection Engineering: Culminating Experience Project Reports

The building I have chosen to use as the model for exemplifying the components of a wet fire suppression system is Westside Christian High School (WCHS). This building completed construction in January of 2014 and is located at: 8200 SW Pfaffle Street Tigard, Oregon 97223. The existing structure was previously owned and occupied by City Bible Church who will now lease space from the High school during and after construction. The renovations include the addition of space for music, art classes, fitness center, gym, science labs, and others. The renovations will also be widening existing rooms and hallways. The core …


Fire And Life Safety Analysis Of The Grant M. Brown Engineering Building- Cal Poly, Daniel Gregory Blanchat Jun 2014

Fire And Life Safety Analysis Of The Grant M. Brown Engineering Building- Cal Poly, Daniel Gregory Blanchat

Fire Protection Engineering: Culminating Experience Project Reports

This fire and life safety analysis was performed on the Grant M. Brown Engineering Building in order to determine if the building meets the life safety goals set forth by a prescriptive and performance based analysis. This building was built to a strict set of codes and standards. For the prescriptive analysis the buildings egress design, fire detection and alarm systems, fire sprinkler system, occupancy classification, construction type, and structural fire protection are evaluated in terms of the life safety of the occupants. In the performance based design analysis four computer based programs were used to model egress and fire …


Fire And Life Safety Analysis- Cal Poly Recreation Center, Connor Mcgill Jun 2014

Fire And Life Safety Analysis- Cal Poly Recreation Center, Connor Mcgill

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this fire and life safety analysis is to determine whether Cal Poly’s Recreation Center meets fire safety goals. The primary fire safety goal is to provide building occupants with an environment that is tenable and allows for safe egress in the event of a fire, and reduce the likelihood of any catastrophic fire event. This goal can be achieved by protecting the occupants not intimate with the initial fire development and improving survivability of those occupants intimate with the initial fire development, NFPA 101, 2012. A prescriptive-based design approach and a performance-based design approach are used to …


Fire Protection And Life Safety Analysis- Dell Medical School Academic Building, David Gramlich Jun 2014

Fire Protection And Life Safety Analysis- Dell Medical School Academic Building, David Gramlich

Fire Protection Engineering: Culminating Experience Project Reports

This report is on the Dell Medical School Academic Building located in Austin, Texas. The life safety and prescriptive based code requirements are summarized within this report. It also includes conceptual fire protection and fire alarm system design. This report mentions University of Texas System Owner’s Design Guidelines that exceed the required code requirements. This report was developed when the building was in the Design Development stage. Since, code deficiencies have been addressed, and changes have been made to the building during the remainder of the design process, this report does not reflect the actual construction or protection strategies used …


Comprehensive Fire And Life Safety Analysis- Moa Public Works Building- Anchorage, Alaska, Andrew J. Bigalke Jun 2014

Comprehensive Fire And Life Safety Analysis- Moa Public Works Building- Anchorage, Alaska, Andrew J. Bigalke

Fire Protection Engineering: Culminating Experience Project Reports

This report is a Comprehensive Fire and Life Safety Analysis addressing both prescriptive and performance based engineering analysis of the MOA Public Works building located in the Municipality of Anchorage, Alaska. The Public Works building was originally built in 1997 under the code requirements of the Uniform Building Code, as a Type II-N building. An addition was constructed in 2002 using the International Building Code (IBC), 2000 Edition. A prescriptive analysis is performed using the requisite building code and standards currently adopted by the State of Alaska, and by the Municipality of Anchorage. The currently adopted building codes and standards …


Fire Protection And Life Safety Evaluation- Hinesville Cboc Va Clinic, Jeff Dew Jun 2014

Fire Protection And Life Safety Evaluation- Hinesville Cboc Va Clinic, Jeff Dew

Fire Protection Engineering: Culminating Experience Project Reports

The Hinesville MOB will be analyzed throughout the course of this report to determine if it meets the prescriptive-based requirements set forth by local and national regulating bodies. Further, a performance-based approach will be taken to assess the buildings ability to sustain life while a safe and timely evacuation occurs. It will be determined that the Hinesville MOB does comply with all regulations set forth for fire and life safety. In some cases its construction and systems may exceed the required minimum standards. It will contain 100% coverage with an automatic sprinkler system, be equipped with adequate emergency notification system, …


Orangeburg Assembly Hall Of Jehovah's Witnesses- Fire Protection And Life Safety Design Analysis, Justin B. Biller Mar 2014

Orangeburg Assembly Hall Of Jehovah's Witnesses- Fire Protection And Life Safety Design Analysis, Justin B. Biller

Fire Protection Engineering: Culminating Experience Project Reports

In partial fulfillment of the requirements for the Degree of Masters of Science in Fire Protection Engineering, a prescriptive and performance-based engineering analysis was performed on the Orangeburg Assembly Hall of Jehovah’s Witnesses. The building was recently constructed and completed in 2013 in Orangeburg, South Carolina to serve as a center for education of Jehovah’s Witnesses on Biblical principles for daily life. More than 300 congregations throughout Georgia and the Carolinas will use the Assembly Hall for their semi-annual assemblies and conventions, with an estimated annual attendance of 190,000 per year. Prescriptive analyses were conducted based primarily upon the provisions …


Fire Protection Life Safety Analysis- Bachelor Enlisted Quarters, Kyle C. Leadon Mar 2014

Fire Protection Life Safety Analysis- Bachelor Enlisted Quarters, Kyle C. Leadon

Fire Protection Engineering: Culminating Experience Project Reports

This Bachelor Enlisted Quarters (BEQ) shall be constructed, arranged, equipped, maintained, and operated in accordance with this report and applicable criteria to ensure a minimum level of life safety and property protection is provided from actual and potential fire hazards. The goal is to ensure the occupants are provided with an environment that is reasonably safe from fire. We accomplish this goal by protecting occupants not intimate with the initial fire development, and by improving the survivability of occupants intimate with the initial fire development. The protection described in this report takes on many forms, from active protection, such as …


Adams 14 High School Life Safety Report, Todd L. Brand Jun 2013

Adams 14 High School Life Safety Report, Todd L. Brand

Fire Protection Engineering: Culminating Experience Project Reports

The purpose of this Life Safety Report (LSR) is to provide a prescriptive based analysis of the Adam County High School based on the existing codes that the building was constructed under. This will include exterior and interior building construction, fire protection systems, and egress requirements. Additionally, this report will evaluate selected performance based design scenarios for the High School. Findings and recommendations to the performance based design scenarios, along with any deficiencies, are noted at the conclusion of the report. The prescriptive analysis of this report will focus on the International Building Code requirements with emphasis on Chapters 4 …


Fire And Life Safety Evaluation Of The Providence Pavilion, Oscar J. Zuniga Jun 2013

Fire And Life Safety Evaluation Of The Providence Pavilion, Oscar J. Zuniga

Fire Protection Engineering: Culminating Experience Project Reports

The fire and life safety systems of the Providence Pavilion, a four-story addition to the Providence Medford Medical Center in Medford, Oregon, are examined for compliance with applicable design and construction codes and standards and are found to comply with codes and conform to standards. The prescriptive requirements for occupancy classification, construction type, structural fire protection, egress systems, fire alarms, and fire protection are reviewed. Three different fire scenarios are developed and are then employed to study the fire and life safety systems’ performance using fire and egress modeling tools and simulations. Using this performance-based approach, the fire and life …


Life Safety Report Xyz Office Building Denver Colorado, Keith Dix Jun 2013

Life Safety Report Xyz Office Building Denver Colorado, Keith Dix

Fire Protection Engineering: Culminating Experience Project Reports

This report is a Life Safety Analysis of the XYZ building in Colorado. It is a government contract facility and as such prefers that its real name and location not be utilized for this report. The building was assessed prescriptively using the 2009 International Building Code (IBC) and was found to be predominantly compliant with the code and the relevant referenced standards. The building was then assessed using a Performance Based Design in accordance with methodologies found and addressed in common fire protection literature. The Design Criteria chosen to determine tenability for the Required Safe Egress Time (RSET) were Carbon …


Fire Protection Analysis Of The ‘Center For The Arts’ Building', Steven W. Carman Jun 2013

Fire Protection Analysis Of The ‘Center For The Arts’ Building', Steven W. Carman

Fire Protection Engineering: Culminating Experience Project Reports

In partial fulfillment of the requirements for the Degree of Masters of Science in Fire Protection Engineering, a prescriptive and performance-based analysis was performed on a building housing the Center for the Arts. The building was constructed in 1947 in California as an automobile dealership and repair shop under the provisions of the then-controlling Uniform Building Code. It subsequently underwent several occupancy changes and has since served as a beauty school, gymnastics center, and currently as a performing and visual arts center. Prescriptive analyses were conducted based primarily upon the provisions of the 2010 California Building and Fire Codes, and …


Robert E. Kennedy Library Cal Poly, San Luis Obispo Fire Protection Analysis Fpe Culminating Project, Isaac De Haro Martinez Mar 2013

Robert E. Kennedy Library Cal Poly, San Luis Obispo Fire Protection Analysis Fpe Culminating Project, Isaac De Haro Martinez

Fire Protection Engineering: Culminating Experience Project Reports

California State University has acquired fire protection services to conduct a survey of and produce a fire protection report that analyzes the current condition of the existing Robert E. Kennedy Library on the Cal Poly campus. The prescriptive analysis of the Library is based on the 2010 California Building- the analysis considers the building a new building and will not consider the building provision for existing buildings as permitted by Chapter 34 of the CBC. A performance-based design using FDS is also analyzed to determine the tenability advantages of providing fire sprinklers within the Library. Non-conforming conditions include, among others, …


Court House Project- Fire Protection Report, Ryan Rigsbee Mar 2013

Court House Project- Fire Protection Report, Ryan Rigsbee

Fire Protection Engineering: Culminating Experience Project Reports

This fire protection report intends to provide Fictitious Architects (The Client) with sufficient information about code requirements and best practices pertaining to occupant and building safety. The chapters within this report include specific design requirements to aid the client during the design of the Court House Project. The following recommendations have been prepared by Ryan Rigsbee to address all major building code requirements for life safety systems. These life safety systems include egress, fire alarm and signaling, water-based fire suppression, structural fire protection, smoke control, and an emergency management plan. This project details the requirements for a new courthouse containing …


Fire And Life Safety Analysis Of The Performing Arts Center's Christopher Cohan Center, David Phillips Mar 2012

Fire And Life Safety Analysis Of The Performing Arts Center's Christopher Cohan Center, David Phillips

Fire Protection Engineering: Culminating Experience Project Reports

This report is a review of the fire protection systems installed in the Christopher Cohan Center on the Cal Poly, San Luis Obispo campus. The systems reviewed are the passive structural fire protection, passive and active egress components, and active detection and suppression systems. The report examines whether the reviewed systems in the building meet the prescriptive requirements of the 2010 California Building Code(CBC) and California Fire Code(CFC). The building will be further subjected to a performance based analysis. Two design fire scenarios are presented, and an analysis of available safe egress time (ASET) is compared with an analysis of …


Fire Protection Analysis Of The Orfalea College Of Business Building (#3), William Fletcher Mar 2012

Fire Protection Analysis Of The Orfalea College Of Business Building (#3), William Fletcher

Fire Protection Engineering: Culminating Experience Project Reports

A performance and prescriptive based analysis was performed on the Orfalea College of Business Building (#3) on Cal Poly’s Campus. The building was originally designed to meet the 1985 Uniform Building Code (UBC). The building’s original design and current existing condition will be examined. The business building will be evaluated using the California Building Code, California Fire Code, NFPA 101 Life Safety code and other relevant NFPA Codes. The fire protection systems will be separated and evaluated into systems by Egress Components, Fire Alarm and Detection, Water- Based Suppression and Structural Fire Protection. The combined interactions of the systems are …


Bulding 192, Engineering Iv, Cal Poly, San Luis Obispo, Mark Ferraresi Mar 2012

Bulding 192, Engineering Iv, Cal Poly, San Luis Obispo, Mark Ferraresi

Fire Protection Engineering: Culminating Experience Project Reports

This report presents a fire and life safety analysis of Engineering IV. This analysis includes a review of prescriptive code requirements per the International Building Code, 2009 Edition and other applicable codes and standards; a description of the current fire and life safety systems or features in place; a prescriptive.based analysis; and a performance.based analysis. Beyond typical fire protection systems, such as means of egress systems and structural fire protection, Engineering IV was found to an automatic fire alarm and notification system, an automatic sprinkler system, and smoke control features. The systems and features surveyed were found to be within …