Open Access. Powered by Scholars. Published by Universities.®

Nuclear Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Nuclear Engineering

Integrated Microsphere Whispering Gallery Mode Probe For Highly Sensitive Refractive Index Measurement, Hanzheng Wang, Lei Yuan, Cheol-Woon Kim, Jie Huang, Xinwei Lan, Hai Xiao Jun 2016

Integrated Microsphere Whispering Gallery Mode Probe For Highly Sensitive Refractive Index Measurement, Hanzheng Wang, Lei Yuan, Cheol-Woon Kim, Jie Huang, Xinwei Lan, Hai Xiao

Nuclear Engineering and Radiation Science Faculty Research & Creative Works

We report an integrated whispering gallery mode microresonator-based sensor probe for refractive index sensing. The probe was made by sealing a borosilicate glass microsphere into a thin-wall glass capillary pigtailed with a multimode optical fiber. The intensities of the resonant peaks were found decreasing exponentially (linearly in a log scale) with the increasing refractive index of the medium surrounding the capillary. The sensing capability of the integrated probe was tested using sucrose solutions of different concentrations and the resolution was estimated to be about 2.5 x 10-5 in the index range of 1.3458 to 1.3847. The integrated sensor probe …


Fiber Pigtailed Thin Wall Capillary Coupler For Excitation Of Microsphere Wgm Resonator, Haining Wang, Xinwei Lan, Jie Huang, Lei Yuan, Cheol-Woon Kim, Hai Xiao Jul 2013

Fiber Pigtailed Thin Wall Capillary Coupler For Excitation Of Microsphere Wgm Resonator, Haining Wang, Xinwei Lan, Jie Huang, Lei Yuan, Cheol-Woon Kim, Hai Xiao

Electrical and Computer Engineering Faculty Research & Creative Works

In this paper, we demonstrate a fiber pigtailed thin wall capillary coupler for excitation of Whispering Gallery Modes (WGMs) of microsphere resonators. The coupler is made by fusion-splicing an optical fiber with a capillary tube and consequently etching the capillary wall to a thickness of a few microns. Light is coupled through the peripheral contact between inserted microsphere and the etched capillary wall. The coupling efficiency as a function of the wall thickness was studied experimentally. WGM resonance with a Q-factor of 1.14 x 104 was observed using a borosilicate glass microsphere with a diameter of 71 µm. The …


The Effect Of Gamma Radiation On Fibre Bragg Grating Sensors When Used As Radiation Dosimeters, Des Baccini Jan 2013

The Effect Of Gamma Radiation On Fibre Bragg Grating Sensors When Used As Radiation Dosimeters, Des Baccini

Theses : Honours

The effects of Gamma Radiation on Fibre Bragg Gratings (FBGs), when used as a radiation dosimeter, was proposed. The focus of this study centred on the FBG performance, and in particular the Bragg Wavelength Shift (BWS) whilst being exposed to ionizing radiation. Current research suggests that certain types of fibres manufactured by varying methods produce different results. The different responses to exposure from gamma irradiation between Germanium (Ge) doped optical fibres, with and without Hydrogen loading, along with the standard SMF-28 fibre with Hydrogen, were used and results noted and compared to previous work. The FBG’s in each fibre were …