Open Access. Powered by Scholars. Published by Universities.®

Nanoscience and Nanotechnology Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 4 of 4

Full-Text Articles in Nanoscience and Nanotechnology

Metamaterials On Parylene Thin Film Substrates: Design, Fabrication, And Characterization At Terahertz Frequency, Xianliang Liu, Samuel Macnaughton, David Shrekenhamer, Hu Tao, Selvapraba Selvarasah, Atcha Totachawattana, Richard Averitt, Mehmet Dokmeci, Sameer Sonkusale, Willie Padilla Jun 2011

Metamaterials On Parylene Thin Film Substrates: Design, Fabrication, And Characterization At Terahertz Frequency, Xianliang Liu, Samuel Macnaughton, David Shrekenhamer, Hu Tao, Selvapraba Selvarasah, Atcha Totachawattana, Richard Averitt, Mehmet Dokmeci, Sameer Sonkusale, Willie Padilla

Mehmet R. Dokmeci

We design, fabricate, and characterize terahertz (THz) resonant metamaterials on parylene free-standing thin film substrates. Several different metamaterials are investigated and our results show strong electromagnetic responses at THz frequencies ranging from 500 GHz to 2.5 THz. The complex frequency dependent dielectric properties of parylene are determined from inversion of reflection and transmission data, thus indicating that parylene is an ideal low loss substrate or coating material. The biostable and biocompatible properties of parylene coupled with the multifunctional exotic properties of metamaterials indicate great potential for medical purposes such as THz imaging for skin cancer detection.


Direct Measurement Of Graphene Adhesion On Silicon Surface By Intercalation Of Nanoparticles, Zong Zong, Chia-Ling Chen, Mehmet Dokmeci, Kai-Tak Wan Jun 2011

Direct Measurement Of Graphene Adhesion On Silicon Surface By Intercalation Of Nanoparticles, Zong Zong, Chia-Ling Chen, Mehmet Dokmeci, Kai-Tak Wan

Mehmet R. Dokmeci

We report a technique to characterize adhesion of monolayered/multilayered graphene sheets on silicon wafer. Nanoparticles trapped at graphene-silicon interface act as point wedges to support axisymmetric blisters. Local adhesion strength is found by measuring the particle height and blister radius using a scanning electron microscope. Adhesion energy of the typical graphene-silicon interface is measured to be 151±28 mJ/m2. The proposed method and our measurements provide insights in fabrication and reliability of microelectromechanical/nanoelectromechanical systems.


Low-Voltage And Short-Channel Pentacene Field-Effect Transistors With Top-Contact Geometry Using Parylene-C Shadow Masks, Yoonyoung Chung, Boris Murmann, Selvapraba Selvarasah, Mehmet Dokmeci, Zhenan Bao Jun 2011

Low-Voltage And Short-Channel Pentacene Field-Effect Transistors With Top-Contact Geometry Using Parylene-C Shadow Masks, Yoonyoung Chung, Boris Murmann, Selvapraba Selvarasah, Mehmet Dokmeci, Zhenan Bao

Mehmet R. Dokmeci

We have fabricated high-performance top-contact pentacene field-effect transistors using a nanometer-scale gate dielectric and parylene-C shadow masks. The high-capacitance gate dielectric, deposited by atomic layer deposition of aluminum oxide, resulted in a low operating voltage of 2.5 V. The flexible and conformal parylene-C shadow masks allowed fabrication of transistors with channel lengths of L = 5, 10, and 20 μm. The field-effect mobility of the transistors was μ = 1.14 (±0.08) cm²/V s on average, and the IMAX/IMIN ratio was greater than 10⁶.


Toxicity Of Cdse Nanoparticles In Caco-2 Cell Cultures, Lin Wang, Dattatri Nagesha, Selvapraba Selvarasah, Mehmet Dokmeci, Rebecca Carrier May 2011

Toxicity Of Cdse Nanoparticles In Caco-2 Cell Cultures, Lin Wang, Dattatri Nagesha, Selvapraba Selvarasah, Mehmet Dokmeci, Rebecca Carrier

Mehmet R. Dokmeci

Background
Potential routes of nanomaterial exposure include inhalation, dermal contact, and ingestion. Toxicology of inhalation of ultra-fine particles has been extensively studied; however, risks of nanomaterial exposure via ingestion are currently almost unknown. Using enterocyte-like Caco-2 cells as a small intestine epithelial model, the possible toxicity of CdSe quantum dot (QD) exposure via ingestion was investigated. Effect of simulated gastric fluid treatment on CdSe QD cytotoxicity was also studied.


Results
Commercially available CdSe QDs, which have a ZnS shell and poly-ethylene glycol (PEG) coating, and in-house prepared surfactant coated CdSe QDs were dosed to Caco-2 cells. Cell viability and attachment …