A Protocol For Automated A Posteriori Adaptive Meshing With Simvascular: A Test Case, Akash Gupta, Ethan Kung Apr 2020

A Protocol For Automated A Posteriori Adaptive Meshing With Simvascular: A Test Case, Akash Gupta, Ethan Kung

Publications

Objective

Operational details regarding the use of the adaptive meshing (AM) algorithm available in the SimVascular package are scarce despite its application in several studies. Lacking these details, novice users of the AM algorithm may experience undesirable outcomes post-adaptation such as increases in mesh error metrics, unpredictable increases in mesh size, and losses in geometric fidelity. Here we present a test case using our proposed iterative protocol that will help prevent these undesirable outcomes and enhance the utility of the AM algorithm. We present three trials (conservative, moderate, and aggressive settings) applied to a scenario modelling a Fontan junction with …