Open Access. Powered by Scholars. Published by Universities.®

Other Materials Science and Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 15 of 15

Full-Text Articles in Other Materials Science and Engineering

Analysis Of Novel Corrosion Resistant Maraging Steels For Use In Additive Manufacturing, Bradley Michael Samuel, James Knowlton Smith Jun 2022

Analysis Of Novel Corrosion Resistant Maraging Steels For Use In Additive Manufacturing, Bradley Michael Samuel, James Knowlton Smith

Materials Engineering

Stainless maraging steel has been proven to be an industry standard material for plastic injection molds. Its high hardness and corrosion resistance extend the lifetime of the tool. This alloy system is also well-suited to additive manufacturing, which can be utilized to form internal cooling channels, further increasing tool life. Using Rapid Alloy Development (RAD) Oerilkon METCO is developing a new composition of stainless maraging tool steel that has high hardness/strength, is corrosion resistant, and has additive-capable melting and solidification properties. This study tests the hardness and corrosion resistance of the new RAD alloys against the current market competitor Corrax …


Non-Destructive Material Analysis Of Metals And Composites Via Thermography, Jonathan R. Doubt, James L. Chapman Jun 2022

Non-Destructive Material Analysis Of Metals And Composites Via Thermography, Jonathan R. Doubt, James L. Chapman

Materials Engineering

The Naval Surface Warfare Center, Port Hueneme Division, is interested in the development of non-destructive damage assessment of shipboard materials via drones at distance. Long Pulsed Thermography (LPT), a method of non-destructive evaluation, was investigated as a possible method for detecting damage in metals (5005h24 Al alloy and 1008 carbon steel) and composites (aramid fiber honeycomb sandwich structure) at distances from 0.5 m to 3.0 m. LPT was conducted using two 1000 W can lights to heat the samples, and a FLIR E8-XT thermal camera. The images were then analyzed using ImageJ software to determine if damage could be detected …


Erosion Resistance Of Tungsten-Carbide Coatings For Steel Pipes In Fluid Catalytic Cracking Units, Davis Vannasing, Jennifer Hulfachor Jun 2019

Erosion Resistance Of Tungsten-Carbide Coatings For Steel Pipes In Fluid Catalytic Cracking Units, Davis Vannasing, Jennifer Hulfachor

Materials Engineering

In petroleum processing, the flow of catalyst readily leads to erosion of piping in a fluid catalytic cracking unit. Advances in coating materials and processes necessitate a re-evaluation of current protection methods. Commercially available tungsten-carbide (WC) claddings and nanostructured WC-W CVD coatings were investigated as potential alternative erosion-resistant coatings. Erosion tests by solid particle impingement were conducted on 2 variations of claddings and 1 variation of WC-W coatings following ASTM standard G76. A36 steel coupons were used as reference samples. For statistical validation, 2-3 replications of the tests were performed for the claddings and WC-W coating. Testing was conducted using …


In Situ Sem Solidification Study Of Ga And Egain: A Characterization Technique For Monitoring The Microstructural Evolution Of Liquid Metals, Jeremy Geovann Del Aguila Jun 2018

In Situ Sem Solidification Study Of Ga And Egain: A Characterization Technique For Monitoring The Microstructural Evolution Of Liquid Metals, Jeremy Geovann Del Aguila

Materials Engineering

Scanning electron microscopy (SEM) video recording is used to characterize the solidification of small volumes of 99.999% pure gallium (Ga) and eutectic gallium-indium (eGaIn) under a high vacuum environment. Specimen are superheated to 55℃ using a hot plate, cast into spherical droplets, and cooled in situ by means of a Peltier cooling stage. Special attention is given to the preparation of the specimen prior to viewing because of gallium and its alloys’ nature to form an oxide layer when melted and air cooled. The oxide acts as a skin that inhibits the observation of microstructural features during solidification. Heated samples …


Comparison Of Intrusive And Non-Intrusive Methods For Corrosion Monitoring Of Fuel Processing Systems, Armando Jacob Espinoza, Thomas Conner Field Jun 2017

Comparison Of Intrusive And Non-Intrusive Methods For Corrosion Monitoring Of Fuel Processing Systems, Armando Jacob Espinoza, Thomas Conner Field

Materials Engineering

This presentation contains an assessment of the best overall corrosion monitoring device, intrusive or non-intrusive, for use in the petrochemical industry. Corrosion in the petrochemical industry is a large issue because it causes a deterioration of pipe integrity in fuel processing systems. A reduction of pipe wall integrity due to corrosion could result in a leak or an explosion of fuel processing lines since those systems function at high pressures. The use of corrosion monitoring systems in the petrochemical industry helps to detect early signs of corrosion prior to failure so that proper maintenance can be performed to prevent catastrophe. …


Effect Of Composition And Build Direction On Additively Manufactured Hastelloy X Alloys, Justin A. Spitzer, Jeffrey T. Schloetter, Sarah Zerga Jun 2017

Effect Of Composition And Build Direction On Additively Manufactured Hastelloy X Alloys, Justin A. Spitzer, Jeffrey T. Schloetter, Sarah Zerga

Materials Engineering

Microcracking has caused premature failure and reduction in properties in additively manufactured (AM) Hastelloy X. The purpose of this research is to meet or exceed the mechanical properties of wrought Hastelloy X by modifying the composition and build direction of Hastelloy X manufactured using Direct Metal Deposition (DMD). Tensile testing, scanning electron microscopy (SEM), and metallography were performed on the samples. ANOVA was used to analyze the dependence that the properties had on build direction and composition. The nominal composition wrought samples had a yield strength of 310.1 MPa and a 60.79% Elongation. Alloy P60-X18 in a horizontal build had …


Characterization Of Slm Printed 316l Stainless Steel And Investigation Of Microlattice Geometry, Finley H. Marbury Jun 2017

Characterization Of Slm Printed 316l Stainless Steel And Investigation Of Microlattice Geometry, Finley H. Marbury

Materials Engineering

The goal of this project was firstly to characterize Cal Poly’s SLM printed 316L stainless steel. SEM analysis showed Cal Poly’s as-printed 316L material to have a cellular dendritic microstructure containing mostly austenite and a small amount of δ-ferrite. After being heat treated to eliminate warp, its yeild and ultimate tensile strength were on par with the literature, however higher modulus and lower elongation were observed. XRD analysis confirmed residual stresses in the material, and that grains are preferentially oriented in both heat treated and non heat treated samples. The amount of porosity in the material was found to be …


Comparison Study Of Tensile Strength , Ductility, And Fracture Mode Of H11, Arp 2000, And Mp35n Connecting Rod Bolts For Use In High Performance Racing Engines, Megan Mccabe, Samuel Randall Jun 2016

Comparison Study Of Tensile Strength , Ductility, And Fracture Mode Of H11, Arp 2000, And Mp35n Connecting Rod Bolts For Use In High Performance Racing Engines, Megan Mccabe, Samuel Randall

Materials Engineering

Oliver Racing Parts (ORP) has historically purchased connecting rod bolts made of high strength, high cost, nickel-cobalt alloy, MP35N, and a medium strength, low cost, proprietary tool steel called ARP 2000. ORP has recently acquired capabilities to manufacture their own bolts. To determine the quality of their product as it compares to their previous supplier, ORP produced three different types of ⅜” diameter bolts: one set of bolts made of MP35N, and two sets of H11 bolts, designated H11A and H11B for their respective processing. The H11, ARP 2000, and MP35N bolts were tensile tested using a custom designed test …


Investigation Of Outlife Time On The Environmental Durability Of P2-Etched, Adhesively-Bonded Aluminum Alloys Using The Astm Wedge Test, Daniel Gross, Corey Sutton Jun 2016

Investigation Of Outlife Time On The Environmental Durability Of P2-Etched, Adhesively-Bonded Aluminum Alloys Using The Astm Wedge Test, Daniel Gross, Corey Sutton

Materials Engineering

P2 etchant is an environmentally-friendly aluminum etchant which has the potential to replace the Forest Products Laboratory (FPL) etchant as the industry standard. Environmental durability of adhesively-bonded aluminum surfaces etched using a paste version of the P2 etchant were tested using the Boeing-developed wedge test (ASTM D3762 - 03(2010)). This project specifically aimed to examine the relationship between outlife time (the time between etching and adhering) and the ability of bonded aluminum samples to pass the wedge test. Two aluminum alloys, 2024-T3 and 7075-T6, were wedge tested and the etched surfaces examined with an atomic force microscope (AFM) and a …


Electrochemical Testing Of Aluminum-Lithium Alloys 2050, 2195, And The Current Aerospace Industry Standard 7075 To Measure The Galvanic Corrosion Behavior With Ti-6al-4v, Trent Duncan, Kevin Knight Jun 2015

Electrochemical Testing Of Aluminum-Lithium Alloys 2050, 2195, And The Current Aerospace Industry Standard 7075 To Measure The Galvanic Corrosion Behavior With Ti-6al-4v, Trent Duncan, Kevin Knight

Materials Engineering

This project aimed to characterize the electrochemical behavior of four different aluminum alloys, and determine how much galvanic corrosion would occur when each alloy was coupled to Ti-6Al-4V. The particular alloys tested were 2050-T3, 2050-T852, 2195-T852, and 7075-T7352. These alloys were tested to determine the effects of aging, and adding lithium, to the corrosion behavior of aluminum alloys. Potentiodynamic polarization curves were generated using the Parstat 2273 potentiostat in accordance with ASTM standard G5, and corrosion analysis software was used to produce Tafel fit lines, which determined the open circuit potential (Ecorr) of each sample. Nine tests were …


Electrochemical Characterization Of Precious Metal Braze Alloys Using Potentiodynamic Polarization, Maxwell Glen Martin, Mason Gregory Morgan, Matthew David Vance Jun 2014

Electrochemical Characterization Of Precious Metal Braze Alloys Using Potentiodynamic Polarization, Maxwell Glen Martin, Mason Gregory Morgan, Matthew David Vance

Materials Engineering

This study aimed to characterize the electrochemical behavior of six precious metal braze alloys by performing potentiodynamic polarization tests (ParStat 2273) based on ASTM Specifications G5 and G59. To determine the extent to which the alloys will contribute to galvanic corrosion in a marine environment (3.5 wt% NaCl), corrosion analysis software was used to produce fitted Tafel lines to determine the open circuit potential, Voc, for each alloy. The Voc values for the alloys were found to be -66.58 mV for Gold ABA, 13.01 mV for Nicoro®, -39.00 mV for Nioro®, 23.4 mV …


Evaluation Of High Phosphorus Electroless Nickel Platings To Protect Carbon Steel Heat Exchangers In Seawater Service, Nathan Brink Jun 2013

Evaluation Of High Phosphorus Electroless Nickel Platings To Protect Carbon Steel Heat Exchangers In Seawater Service, Nathan Brink

Materials Engineering

The purpose of this project was to determine the suitability of using a high phosphorus electroless nickel (HPEN) coating to prevent corrosion in carbon steel heat exchangers in seawater service. 1 in. x 4 in. samples were cut from ¼ in. SA-516-70 pressure vessel plate, pickled to remove mill scale, dressed with 300 grit sand paper and sent out for plating with 2 mils of HPEN. Due to a clerical error during plating, samples were plated to a significantly lesser extent than requested. Samples were plated with approximately 0.6 mils of HPEN versus the 2 mils requested, however this was …


Analyzing The Corrosion Resistance Of Ni-Shield 200 Coatings At Different Temperatures When Exposed To Sulphuric Acid, Alex Hussinger Jun 2012

Analyzing The Corrosion Resistance Of Ni-Shield 200 Coatings At Different Temperatures When Exposed To Sulphuric Acid, Alex Hussinger

Materials Engineering

Six steel samples each were twin wire arc sprayed with Hastelloy C-276 or Nickel-Shield 200 coatings approximately 0.020″ thick. These samples were then cut into 3″ by 3″ squares. A 2″ diamond grit hole saw was used to abrade and polish to a smooth surface a ring in the middle in order to get an O-ring mechanical seal. The samples were then weighed and loaded into a jig that started from the bottom up with a stainless steel plate, then the sample, then a Viton O-ring, a ¾″ thick glass plate with a 1 3/4″ hole cut in it, another …


The Effects Of Heat Treatment On Area Percent Porosity And Corrosion Behavior Of High-Nickel Thermal Spray Coatings, Travis Crowe, Alec Guraydin Jun 2011

The Effects Of Heat Treatment On Area Percent Porosity And Corrosion Behavior Of High-Nickel Thermal Spray Coatings, Travis Crowe, Alec Guraydin

Materials Engineering

Samples of two Thermal Spray Coating (TSC) alloys on a low carbon steel substrate were obtained: alloy C276 and Nicko-Shield 200. Specimens of each alloy were subjected to heat treatments at temperatures at 1100° for 60 minutes and 1200° for 10 minutes, with some specimens left in the as-sprayed condition. Three replicates were prepared for each condition. Thin 1” strips were cut using a diamond wafering blade for porosity measurements and 2” x 1” specimens were cut for corrosion testing using a SiC abrasive saw. The porosity specimens were mounted in acrylic resin, polished, and examined using SEM. From these …


Characterization Of Aluminum-Boron Carbide Particulate Metal Matrix Composites, Eric Blank Jun 2010

Characterization Of Aluminum-Boron Carbide Particulate Metal Matrix Composites, Eric Blank

Materials Engineering

The analysis of die-cast 380 aluminum-boron carbide particulate metal matrix composites (MMC) was performed in order to see if the samples had the required tensile strength of 300 MPa. 10wt% B4C die-cast samples were produced and tested. Half were heat treated to the T6 condition and the others were left as cast. Using ASTM standard B 557M it was found that the average tensile strength for the as-cast samples was 130 MPa and the heat treated samples had a tensile strength of 93 MPa. These values were both lower than expected. The heat treated samples were not expected to have …