Open Access. Powered by Scholars. Published by Universities.®
- Keyword
-
- 3D-Printing (1)
- Biomechanics (1)
- Bladder (1)
- Coronary stent (1)
- Elastomers (1)
-
- Esophageal stent (1)
- Finite element analysis (1)
- Finite element method (1)
- Finite element model (1)
- Flared (1)
- In-stent restenosis (1)
- Intravesical tunnel length (1)
- Migration (1)
- Orthotics (1)
- Personalized Medicine (1)
- Rehabilitation (1)
- Stent design (1)
- Stent length (1)
- Ureteral orifice (1)
- Ureterovesical junction competence (1)
- Vessel geometry (1)
- Publication
- Publication Type
Articles 1 - 4 of 4
Full-Text Articles in Mechanics of Materials
Migration Resistance Of Esophageal Stents: The Role Of Stent Design, Hozhabr Mozafari, Pengfei Dong, Shijia Zhao, Yonghua Bi, Xinwei Han, Linxia Gu
Migration Resistance Of Esophageal Stents: The Role Of Stent Design, Hozhabr Mozafari, Pengfei Dong, Shijia Zhao, Yonghua Bi, Xinwei Han, Linxia Gu
Department of Mechanical and Materials Engineering: Faculty Publications
Objective: Stenting is one of the major treatments for malignant esophageal cancer. However, stent migration compromises clinical outcomes. A flared end design of the stent diminishes its migration. The goal of this work is to quantitatively characterize stent migration to develop new strategies for better clinical outcomes.
Methods: An esophageal stent with flared ends and a straight counterpart were virtually deployed in an esophagus with asymmetric stricture using the finite element method. The resulted esophagus shape, wall stress, and migration resistance force of the stent were quantified and compared.
Results: The lumen gain for both the flared stent and the …
Ureteral Tunnel Length Versus Ureteral Orifice Configuration In The Determination Of Ureterovesical Junction Competence: A Computer Simulation Model, Carlos A. Villanueva, J. Tong, Carl A. Nelson, Linxia Gu
Ureteral Tunnel Length Versus Ureteral Orifice Configuration In The Determination Of Ureterovesical Junction Competence: A Computer Simulation Model, Carlos A. Villanueva, J. Tong, Carl A. Nelson, Linxia Gu
Department of Mechanical and Materials Engineering: Faculty Publications
Introduction The long-held belief that a ureteral re-implant tunnel should be five times the diameter of the ureter, as proposed by Paquin in 1959, ignores the effect of the orifice on the occurrence of reflux. In 1969, Lyon proposed that the shape of the ureteral orifice (UO) is more important than the intravesical tunnel. However, both theories missed quantitative evidence from principles of physics. The goal of the current study was to test Lyon’s theory through numerical models (i.e. to quantify the sensitivity of ureterovesical junction (UVJ) competence to intravesical tunnel length and to the UO).
Materials and methods The …
Tissue Stresses In Stented Coronary Arteries With Different Geometries: Effect Of The Relation Between Stent Length And Lesion Length, Xiang Shen, Song Ji, Yong-Quan Deng, Hong-Fei Zhu, Jia-Bao Jiang, Linxia Gu
Tissue Stresses In Stented Coronary Arteries With Different Geometries: Effect Of The Relation Between Stent Length And Lesion Length, Xiang Shen, Song Ji, Yong-Quan Deng, Hong-Fei Zhu, Jia-Bao Jiang, Linxia Gu
Department of Mechanical and Materials Engineering: Faculty Publications
In-stent restenosis after stent deployment remains an obstruction in the long-term benefits of stenting. This study sought to investigate the influence of the relation between stent length and lesion length on the mechanics of the arterial wall with different geometries, including straight and tapered vessels. Results showed that when the length of the stent was longer than the lesion length, the maximum stress in plaque and vessel increased as the length of stent increased. When the length of the stent was shorter than the lesion length, the vessel stress induced by stent inflation was lower; both ends of the stenosis …
Design And Analysis Of A 3d-Printed, Thermoplastic Elastomer (Tpe) Spring Element For Use In Corrective Hand Orthotics, Kevin Thomas Richardson
Design And Analysis Of A 3d-Printed, Thermoplastic Elastomer (Tpe) Spring Element For Use In Corrective Hand Orthotics, Kevin Thomas Richardson
Theses and Dissertations--Mechanical Engineering
This thesis proposes an algorithm that determine the geometry of 3D-printed, custom-designed spring element bands made of thermoplastic elastomer (TPE) for use in a wearable orthotic device to aid in the physical therapy of a human hand exhibiting spasticity after stroke. Each finger of the hand is modeled as a mechanical system consisting of a triple-rod pendulum with nonlinear stiffness at each joint and forces applied at the attachment point of each flexor muscle. The system is assumed quasi-static, which leads to a torque balance between the flexor tendons in the hand, joint stiffness and the design force applied to …