Impact Of Clip Connection And Insulation Thickness On Bracing Of Purlins In Standing Seam Roof Systems, Michael W. Seek, Daniel Mclaughlin Jan 2017

Impact Of Clip Connection And Insulation Thickness On Bracing Of Purlins In Standing Seam Roof Systems, Michael W. Seek, Daniel Mclaughlin

Engineering Technology Faculty Publications

The flexural strength of purlins in standing seam roof systems is highly dependent upon the extent to which the sheathing provides lateral and torsional restraint. Typical models to predict the restraint provided by the sheathing assume that the plane of lateral resistance occurs at the top flange of the purlin. In reality, depending on the configuration of the clip and the amount of insulation located between the purlin and the clip, the plane of lateral resistance and corresponding center of rotation shifts above the top flange. This distance, referred to as the effective standoff, is important to evaluate the effectiveness …