Open Access. Powered by Scholars. Published by Universities.®

Electrical and Electronics Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 11 of 11

Full-Text Articles in Electrical and Electronics

Co-Designing Situated Displays For Family Co-Regulation With Adhd Children, Lucas M. Silva, Franceli L. Cibrian, Clarisse Bonang, Arpita Bhattacharya, Aehong Min, Elissa M. Monteiro, Jesus A. Beltran, Sabrina E. B. Schuck, Kimberley D. Lakes, Gillian R. Hayes, Daniel A. Epstein May 2024

Co-Designing Situated Displays For Family Co-Regulation With Adhd Children, Lucas M. Silva, Franceli L. Cibrian, Clarisse Bonang, Arpita Bhattacharya, Aehong Min, Elissa M. Monteiro, Jesus A. Beltran, Sabrina E. B. Schuck, Kimberley D. Lakes, Gillian R. Hayes, Daniel A. Epstein

Engineering Faculty Articles and Research

Family informatics often uses shared data dashboards to promote awareness of each other’s health-related behaviors. However, these interfaces often stop short of providing families with needed guidance around how to improve family functioning and health behaviors. We consider the needs of family co-regulation with ADHD children to understand how in-home displays can support family well-being. We conducted three co-design sessions with each of eight families with ADHD children who had used a smartwatch for self-tracking. Results indicate that situated displays could nudge families to jointly use their data for learning and skill-building. Accommodating individual needs and preferences when family members …


Engineering Electromagnetic Systems For Next-Generation Brain-Machine Interface, Brayan Ricardo Navarrete Nov 2020

Engineering Electromagnetic Systems For Next-Generation Brain-Machine Interface, Brayan Ricardo Navarrete

FIU Electronic Theses and Dissertations

MagnetoElectric Nanoparticles (MENPs) are known to be a powerful tool for a broad range of applications spanning from medicine to energy-efficient electronics. MENPs allow to couple intrinsic electric fields in the nervous system with externally controlled magnetic fields. This thesis exploited MENPs to achieve contactless brain-machine interface (BMIs). Special electromagnetic devices were engineered for controlling the MENPs’ magnetoelectric effect to enable stimulation and recording. The most important engineering breakthroughs of the study are summarized below.

(I) Metastable Physics to Localize Nanoparticles: One of the main challenges is to localize the nanoparticles at any selected site(s) in the brain. The fundamental …


Multivariate Analysis For The Quantification Of Transdermal Volatile Organic Compounds In Humans By Proton Exchange Membrane Fuel Cell System, Ahmed Hasnain Jalal Nov 2018

Multivariate Analysis For The Quantification Of Transdermal Volatile Organic Compounds In Humans By Proton Exchange Membrane Fuel Cell System, Ahmed Hasnain Jalal

FIU Electronic Theses and Dissertations

In this research, a proton exchange membrane fuel cell (PEMFC) sensor was investigated for specific detection of volatile organic compounds (VOCs) for point-of-care (POC) diagnosis of the physiological conditions of humans. A PEMFC is an electrochemical transducer that converts chemical energy into electrical energy. A Redox reaction takes place at its electrodes whereas the volatile biomolecules (e.g. ethanol) are oxidized at the anode and ambient oxygen is reduced at the cathode. The compounds which were the focus of this investigation were ethanol (C2H5OH) and isoflurane (C3H2ClF5O), but theoretically, the sensor …


Nanofabrication And Spectroscopy Of Magnetic Nanostructures Using A Focused Ion Beam, Ali Hadjikhani Jul 2016

Nanofabrication And Spectroscopy Of Magnetic Nanostructures Using A Focused Ion Beam, Ali Hadjikhani

FIU Electronic Theses and Dissertations

This research used a focused ion beam in order to fabricate record small nano-magnetic structures, investigate the properties of magnetic materials in the rarely studied range of nanometer size, and exploit their extraordinary characteristics in medicine and nano-electronics. This study consists of two parts: (i) Fabrication and study of record small magnetic tunnel junctions (ii) Introduction of a novel method for detection of magnetoelectric nanoparticles (MENs) in the tissue.

A key challenge in further scaling of CMOS devices is being able to perform non-volatile logic with near zero power consumption. Sub-10-nm nanomagnetic spin transfer torque (STT) magnetic tunneling junctions (MTJs) …


Design And Development Of Two Component Hydrogel Ejector For Three-Dimensional Cell Growth, Thomas Dunkle, Jessica Deschamps, Connie Dam May 2015

Design And Development Of Two Component Hydrogel Ejector For Three-Dimensional Cell Growth, Thomas Dunkle, Jessica Deschamps, Connie Dam

Honors Scholar Theses

Hydrogels are useful in wound healing, drug delivery, and tissue engineering applications, but the available methods of injecting them quickly and noninvasively are limited. The medical industry does not yet have access to an all-purpose device that can quickly synthesize hydrogels of different shapes and sizes. Many synthesis procedures that have been developed result in the formation of amorphous hydrogels. While generally useful, amorphous hydrogels exhibit limited capability in tissue engineering applications, especially due to their viscous properties. This endeavor aims to modulate the appropriate gelation parameters, optimize the injection process, and create a prototype that allows for the extrusion …


Two-Dimensional Layered Mos2 Biosensors Enable Highly Sensitive Detection Of Biomolecules, Joonhyung Lee, Piyush Dak, Yeonsung Lee, Heekyeong Park, Woong Choi, Muhammad Ashraful Alam, Sunkook Kim Dec 2014

Two-Dimensional Layered Mos2 Biosensors Enable Highly Sensitive Detection Of Biomolecules, Joonhyung Lee, Piyush Dak, Yeonsung Lee, Heekyeong Park, Woong Choi, Muhammad Ashraful Alam, Sunkook Kim

Birck and NCN Publications

We present a MoS2 biosensor to electrically detect prostate specific antigen (PSA) in a highly sensitive and label-free manner. Unlike previous MoS2-FET-based biosensors, the device configuration of our biosensors does not require a dielectric layer such as HfO2 due to the hydrophobicity of MoS2. Such an oxide-free operation improves sensitivity and simplifies sensor design. For a quantitative and selective detection of PSA antigen, anti-PSA antibody was immobilized on the sensor surface. Then, introduction of PSA antigen, into the anti-PSA immobilized sensor surface resulted in a lable-free immunoassary format. Measured off-state current of the device …


Nanopulse Generators: Their Design And Application To Cancer Therapy Studies, Daniel P. Wernig Dec 2014

Nanopulse Generators: Their Design And Application To Cancer Therapy Studies, Daniel P. Wernig

Senior Honors Theses

Effective nanopulse generators have become critical in recent decades concerning the study of subcellular affects in response to nanosecond pulsed electric fields. It has been observed that nanosecond duration electric pulses can target intracellular organelles, ultimately leading to cell apoptosis, suggesting the possibility of a new, minimally invasive, low risk cancer therapy methodology. The standard topology for developing a medical nanopulser is the Blumlein “transmission line” approach. This approach relies on the nearly infinitesimal, yet finite amount of time required for an electromagnetic field to propagate down a short transmission line. Prior to design, requirements and constraints must be defined …


Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle Jan 2011

Intelligibility Of Electrolarynx Speech Using A Novel Hands-Free Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal or plastic plate at a frequency within the range of glottal excitation. In this paper, the intelligibility of speech produced using a novel hands-free actuator is compared to speech produced using a conventional electrolarynx. Two able-bodied speakers (one male, one female) performed a closed response test containing 28 monosyllabic words, once using a conventional electrolarynx and a second time using the novel design. The resulting audio recordings …


Augmented Control Of A Hands-Free Electrolarynx, Brian Madden, James Condron, Eugene Coyle Jan 2011

Augmented Control Of A Hands-Free Electrolarynx, Brian Madden, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx acts as the sound source, providing a quasi-periodic excitation of the vocal tract. Following a total laryngectomy, some people speak using an electrolarynx which employs an electromechanical actuator to perform the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the monotonic sound emitted, the need for a free-hand to operate the device, and the difficulty experienced by many laryngectomees in adapting to its use. One improvement to the electrolarynx, which clinicians and users frequently suggest, is the provision of a convenient hands-free control facility. This would allow more natural use of …


Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle Jun 2010

Intelligibility Of Electrolarynx Speech Using A Novel Actuator, Brian Madden, Mark Nolan, Ted Burke, James Condron, Eugene Coyle

Conference Papers

During voiced speech, the larynx provides quasi-periodic acoustic excitation of the vocal tract. Following a laryngectomy, some people speak using an electrolarynx which replaces the excitatory function of the absent larynx. Drawbacks of conventional electrolarynx designs include the buzzing monotonic sound emitted, the need for a free hand to operate the device, and difficulty experienced by many laryngectomees in adapting to its use. Despite these shortcomings, it remains the preferred method of speech rehabilitation for a substantial minority of laryngectomees. In most electrolarynxes, mechanical vibrations are produced by a linear electromechanical actuator, the armature of which percusses against a metal …


Improved Energy Model For Membrane Electroporation In Biological Cells Subjected To Electrical Pulses, R. P. Joshi, Q. Hu, K. H. Schoenbach, H. P. Hjalmarson Jan 2002

Improved Energy Model For Membrane Electroporation In Biological Cells Subjected To Electrical Pulses, R. P. Joshi, Q. Hu, K. H. Schoenbach, H. P. Hjalmarson

Bioelectrics Publications

A self-consistent model analysis of electroporation in biological cells has been carried out based on an improved energy model. The simple energy model used in the literature is somewhat incorrect and unphysical for a variety of reasons. Our model for the pore formation energy E(r) includes a dependence on pore population and density. It also allows for variable surface tension, incorporates the effects of finite conductivity on the electrostatic correction term, and is dynamic in nature. Self-consistent calculations, based on a coupled scheme involving the Smoluchowski equation and the improved energy model, are presented. It is shown that E(r) becomes …