Switch Yard Operation In Thermal Power Plant(Katpp Jhalawar Rajasthan), Radhey Shyam Meena Er. Jul 2012

Switch Yard Operation In Thermal Power Plant(Katpp Jhalawar Rajasthan), Radhey Shyam Meena Er.

Radhey Shyam Meena

Switchyard Provides the facilities for switching ,protection & Control of electric power. To handle high Voltage power with proper Safety measures. To isolate the noises coming from the grid with true 50Hz power SWITCH YARD IS IMPORTANT PART IN THERMAL PLANT. IN KALISINDH THERMAL 400KV AND 220KV SWITCH YARD LOCATED.


Modeling And Simulation Of Z-Source Inverter, Suresh L Jan 2012

Modeling And Simulation Of Z-Source Inverter, Suresh L

suresh L

Z – source inverters have been recently proposed as an alternative power conversion concept as they have both voltage buck and boost capabilities. These inverters use a unique impedance network, coupled between the power source and converter circuit, to provide both voltage buck and boost properties, which cannot be achieved with conventional voltage source and current source inverters. To facilitate understanding of Z – source inverter, this paper presents a detailed analysis, showing design of impedance network, implementation of simple Boost control PWM technique and simulation of Z – source inverter for different values of modulation indices.