Open Access. Powered by Scholars. Published by Universities.®

Controls and Control Theory Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 5 of 5

Full-Text Articles in Controls and Control Theory

Safe Haptics-Enabled Patient-Robot Interaction For Robotic And Telerobotic Rehabilitation Of Neuromuscular Disorders: Control Design And Analysis, Seyed Farokh Atashzar Dec 2016

Safe Haptics-Enabled Patient-Robot Interaction For Robotic And Telerobotic Rehabilitation Of Neuromuscular Disorders: Control Design And Analysis, Seyed Farokh Atashzar

Electronic Thesis and Dissertation Repository

Motivation: Current statistics show that the population of seniors and the incidence rate of age-related neuromuscular disorders are rapidly increasing worldwide. Improving medical care is likely to increase the survival rate but will result in even more patients in need of Assistive, Rehabilitation and Assessment (ARA) services for extended periods which will place a significant burden on the world's healthcare systems. In many cases, the only alternative is limited and often delayed outpatient therapy. The situation will be worse for patients in remote areas. One potential solution is to develop technologies that provide efficient and safe means of in-hospital and …


Synchronization Of Coupled Neurons Via Robust Feedback, Hector Puebla, Ricardo Aguilar-Lopez, Priti Kumar Roy Oct 2016

Synchronization Of Coupled Neurons Via Robust Feedback, Hector Puebla, Ricardo Aguilar-Lopez, Priti Kumar Roy

Annual Symposium on Biomathematics and Ecology Education and Research

No abstract provided.


A Stroke Therapy Brace Design, Evan Kirkbride Jun 2016

A Stroke Therapy Brace Design, Evan Kirkbride

Electrical Engineering

Victims of stroke often have difficulty with rehabilitation. With limited movement on their affected arm, patients often do not want to move much for physical therapy. In this project, we design a robotic brace that helps stroke patients move their arm more effectively in a reaching or pulling motion. By giving patients more movement in their affected arm than they would have otherwise, patients gain more from rehabilitation. The brace also adapts to the patient’s needs, providing more inclination or resistance as needed for their physical therapy. This kind of therapy engages patients rather than relying on their likely dwindled …


Exertion Control, Travis Taylor Jun 2016

Exertion Control, Travis Taylor

Electrical Engineering

Current wearable fitness devices give the user after-the-fact fitness data, but little real-time feedback. Exertion Control, a new wearable device, continuously measures the user’s heart rate, creates a heart rate target, and helps the user reach it. This project completes the senior design and master’s thesis requirements and contains two milestones. The senior design product continuously measures the wearer’s heart rate and logs it with a user-friendly interface. This data models the heart’s exertion response and recovery response. The master’s thesis device refines the closed control loop with the user to give them a workout optimized to fit their needs.


Design And Performance Evaluation Of A Prototype Mrf-Based Haptic Interface For Medical Applications, Mehrdad Kermani Ph.D., P.Eng., Nima Najmaei, Ali Asadian, Rajni Patel Feb 2016

Design And Performance Evaluation Of A Prototype Mrf-Based Haptic Interface For Medical Applications, Mehrdad Kermani Ph.D., P.Eng., Nima Najmaei, Ali Asadian, Rajni Patel

Electrical and Computer Engineering Publications

This paper describes the construction and stability and transparency evaluation of a prototype two degrees-of-freedom (DoF) haptic interface, which takes ad-vantage of magneto-rheological fluid (MRF)-based clutches for actuation. These small-scale clutches were designed in our lab, and their evaluation were reported previously [1],[2]. MRF-based actuators exhibit superior characteristics,which can significantly contribute to transparency and stability of haptic devices. Based on these actuators, a distributed antagonistic configuration is used to develop the2-DoF haptic interface. This device is incorporated in a master–slave teleoperation setup intended for medical per-cutaneous interventions and soft-tissue palpation. Preliminary studies on the stability and transparency of the haptic …