Open Access. Powered by Scholars. Published by Universities.®

Other Computer Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 3 of 3

Full-Text Articles in Other Computer Engineering

A Comparative Evaluation Of The Detection And Tracking Capability Between Novel Event-Based And Conventional Frame-Based Sensors, James P. Boettiger Mar 2020

A Comparative Evaluation Of The Detection And Tracking Capability Between Novel Event-Based And Conventional Frame-Based Sensors, James P. Boettiger

Theses and Dissertations

Traditional frame-based technology continues to suffer from motion blur, low dynamic range, speed limitations and high data storage requirements. Event-based sensors offer a potential solution to these challenges. This research centers around a comparative assessment of frame and event-based object detection and tracking. A basic frame-based algorithm is used to compare against two different event-based algorithms. First event-based pseudo-frames were parsed through standard frame-based algorithms and secondly, target tracks were constructed directly from filtered events. The findings show there is significant value in pursuing the technology further.


Respiratory Prediction And Image Quality Improvement Of 4d Cone Beam Ct And Mri For Lung Tumor Treatments, Seonyeong Park Jan 2017

Respiratory Prediction And Image Quality Improvement Of 4d Cone Beam Ct And Mri For Lung Tumor Treatments, Seonyeong Park

Theses and Dissertations

Identification of accurate tumor location and shape is highly important in lung cancer radiotherapy, to improve the treatment quality by reducing dose delivery errors. Because a lung tumor moves with the patient's respiration, breathing motion should be correctly analyzed and predicted during the treatment for prevention of tumor miss or undesirable treatment toxicity. Besides, in Image-Guided Radiation Therapy (IGRT), the tumor motion causes difficulties not only in delivering accurate dose, but also in assuring superior quality of imaging techniques such as four-dimensional (4D) Cone Beam Computed Tomography (CBCT) and 4D Magnetic Resonance Imaging (MRI). Specifically, 4D CBCT used in CBCT …


Simultaneous Range/Velocity Detection With An Ultra-Wideband Random Noise Radar Through Fully Digital Cross-Correlation In The Time Domain, James R. Lievsay Mar 2011

Simultaneous Range/Velocity Detection With An Ultra-Wideband Random Noise Radar Through Fully Digital Cross-Correlation In The Time Domain, James R. Lievsay

Theses and Dissertations

This research effort examines the theory, application, and results of applying two-dimensional cross-correlation in the time domain to ultra-wideband (UWB) random noise waveforms for simultaneous range and velocity estimation. When applying common Doppler processing techniques to random noise waveforms for the purpose of velocity estimation, the velocity resolution degrades as the signal bandwidth or the target speed increase. To mitigate the degradation, the Doppler approximation is not utilized, and instead, wideband signal processing theory is applied in the time domain. The results show that by accurately interpolating each sample in the digitized reference signal, a target's velocity and range can …