Analytical And Experimental Studies To Support Codification Of Lightweight Grout For Masonry Design, Cooper Banks May 2024

Analytical And Experimental Studies To Support Codification Of Lightweight Grout For Masonry Design, Cooper Banks

All Theses

Lightweight (LW) aggregates have many potential benefits in masonry construction including minimizing mass, improving thermal performance, and reducing the potential for shrinkage cracking via internal curing. The current masonry design standard, TMS 402/602-22, permits lightweight aggregate in the production of concrete masonry units (CMU), but there has been insufficient testing of masonry assemblies to permit designing with LW grout. Shrestha et al. characterized LW grouts bond to reinforcement, shear strength, tension and shear pullout behavior of anchors and proposed possible reduction factors for design. Hiner characterized the flexural bond strength LW grouted masonry assemblies and proposed possible reduction factors for …


Investigation Of Natural Pozzolans: Analyzing The Practicality Of Natural Pozzolans As A Partial Substitute For Cement In Grout Production, Jadyn I. Breien, Andrew J. Baro, Logan T. Marino Jun 2023

Investigation Of Natural Pozzolans: Analyzing The Practicality Of Natural Pozzolans As A Partial Substitute For Cement In Grout Production, Jadyn I. Breien, Andrew J. Baro, Logan T. Marino

Architectural Engineering

This senior project aims to investigate whether natural pozzolans are more sustainable than fly ash and a sufficient substitute for cement in the production of grout. By following the intent of the ASTM (American Society of Testing and Materials) standards, a conclusion will be made to determine if natural pozzolans can contribute comparable strength in compression. The objective is to prove that natural pozzolans should be utilized in the production of grout rather than alternatives such as fly ash because it can provide similar strength while being more economical and more sustainable.


Flexural Bond Strength Of Masonry Assemblies With Lightweight Grout, Benjamin L. Hiner Dec 2022

Flexural Bond Strength Of Masonry Assemblies With Lightweight Grout, Benjamin L. Hiner

All Theses

Lightweight grout has many potential benefits in masonry construction, including minimizing mass, improving thermal performance, and potentially reducing shrinkage cracking via internal curing. However, insufficient testing of masonry assemblies with lightweight grout has been conducted to suggest appropriate design modification factors akin to the lambda factor in ACI 318-19. The objective of this paper is to study the tensile bond behavior of masonry assemblies grouted with lightweight grout and to suggest appropriate equations for predicting design capacity. A moment couple test is designed specifically for grouted masonry assemblies and has additional capacity compared to the traditional ASTM 1072 bond wrench …


Performance Based Design And Machine Learning In Structural Fire Engineering: A Case For Masonry, Deanna Craig Dec 2022

Performance Based Design And Machine Learning In Structural Fire Engineering: A Case For Masonry, Deanna Craig

All Theses

The volatile and extreme nature of fire makes structural fire engineering unique in that the load actions dictating design are intense but not geographically or seasonally bound. Simply, fire can break out anywhere, at any time, and for any number of reasons. Despite the apparent need, fire design of structures still relies on expensive fire tests, complex finite element simulations, and outdated procedures with little room for innovation. This thesis will make a case for adopting the principles of performance-based design and machine learning in structural fire engineering to simplify the process and promote the consideration of fire in all …


Development Of Lambda Factors For Masonry Design With Lightweight Grout, Rumi Shrestha Dec 2021

Development Of Lambda Factors For Masonry Design With Lightweight Grout, Rumi Shrestha

All Theses

Reduction in structural mass, improvement in thermal performance, and reduction in shrinkage cracking through internal curing are some of the reasons that lightweight (LW) aggregates have been used in structures and pavements for decades. However, lightweight grout is still not permitted for use in reinforced masonry construction by the TMS 402/602-16 code. In order to realize the benefits of lightweight grout in U.S. reinforced masonry construction, a codified procedure for its use is required which must be informed by experimental testing.

This research is a pilot project directed to characterize the performance of LW grout in comparison to normal weight …


Design Of Load Bearing Wall For Low Rise Building With Partially Grouted Reinforced Masonry, Anil Bhatt May 2021

Design Of Load Bearing Wall For Low Rise Building With Partially Grouted Reinforced Masonry, Anil Bhatt

Honors Theses

The seismic and wind load acting on the 2-storeyed building of dimension 120 ft x 98 ft located in Oxford, MS, were calculated and the seismic load was considered for the design of the 120 ft long and 24 ft high load-bearing wall because it being critical. The maximum loading was computed using different load combinations. The masonry behavior and masonry specifications were considered to select the masonry unit, grout, and mortar for the load-bearing wall. The seismic design requirement for the shear and slender wall was fulfilled for the special reinforced masonry wall. The in-plane and out-of-plane loading scenarios …


Tanzanian Concrete Masonry Walls, Edward J. Kaminski Dec 2020

Tanzanian Concrete Masonry Walls, Edward J. Kaminski

Architectural Engineering