Open Access. Powered by Scholars. Published by Universities.®

Structural Engineering Commons

Open Access. Powered by Scholars. Published by Universities.®

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

Cold formed steel; shear connector; ductility; strength resistance; composite beam; push test

Articles 1 - 1 of 1

Full-Text Articles in Structural Engineering

Push Tests On Innovative Shear Connector For Composite Beam With Cold-Formed Steel Section, S. O. Bamaga, M. M. Tahir, C. S. Tan Aug 2012

Push Tests On Innovative Shear Connector For Composite Beam With Cold-Formed Steel Section, S. O. Bamaga, M. M. Tahir, C. S. Tan

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

In this study, experimental tests were conducted to investigate the ductility and strength capacity of new shear connector. Push test specimens were prepared and tested according to EN1994-1-1 standard. The push test specimen consists of two cold-formed steel lipped channel sections oriented back-to-back to form an I-section beam, transverse metal deck and normal concrete slabs grade C25/30. Angle brackets were obtained from the same section of the beam and fastened to the web of steel beam to provide the shear connection. Two shear connectors were tested namely; “SC1” and “SC2” shear connectors. Both shear connectors showed a ductile behavior and …