Built-up section||modified slenderness ratio||axial strength

Articles 1 - 1 of 1

Full-Text Articles in Structural Engineering

Comparative Behavior Of Built-Up Cold-Formed Box Sections Under Rigid And Flexible End Support Conditions, W. Reyes, F. A. Guzman Nov 2010

Comparative Behavior Of Built-Up Cold-Formed Box Sections Under Rigid And Flexible End Support Conditions, W. Reyes, F. A. Guzman

CCFSS Proceedings of International Specialty Conference on Cold-Formed Steel Structures (1971 - 2018)

According to section D1.2 of AISI S100-2007 for compression members composed of two sections in contact whose buckling mode involves shear forces in the connectors, a reduction must be made, KL r ⁄ must be replaced by ሺ KL r ⁄ሻ ୫ . This new modified slenderness ratio takes into account the connection weld spacing and the minimum radius of gyration of an individual shape in the built-up member. Under the provisions of section D1.2 a reduction in load capacity must be made for built-up welded box members, which are the subject of this study. An experimental investigation on 48 …