Review Of Fly-Ash As A Supplementary Cementitious Material, Nikki Shaji, Niall Holmes Dr., Mark Tyrer Aug 2022

Review Of Fly-Ash As A Supplementary Cementitious Material, Nikki Shaji, Niall Holmes Dr., Mark Tyrer

Conference papers

This paper presents a review of fly-ash as a Supplementary Cementitious Material (SCM) in concrete in terms of its effects on hydration and durability. The climate change agenda has focused the cement and concrete industry on using low embodied CO2 materials and much effort has been made on incorporating industrial by-products into cement as SCMs. With worldwide cement production (circa 4 billion tonnes) currently accounting for approximately 8% of global CO2 emissions and 7% of industry energy use, the use of suitable SCMs to partially replace cement in concrete is extremely important. However, while coal-fired power stations are in the …


Evaluating A New Cem Iii/A Cement For Concretes Exposed To Harsh Acid Rich Environments, David Thompson, Niall Holmes, John Reddy Jan 2016

Evaluating A New Cem Iii/A Cement For Concretes Exposed To Harsh Acid Rich Environments, David Thompson, Niall Holmes, John Reddy

Conference papers

The Irish Annex to the European specification, performance, production and conformity of concrete, IS EN 206, recommends CEM III/B cement for acid rich environments containing between 66 to 80% GGBS. However, BS 8500, the UK annex to EN 206 and the British Research Establishment (BRE) Special Digest 1, recommends CEM III/A cement with a GGBS range of 36-65%. This project investigated the performance of a new CEM III/A cement produced by Ecocem Ireland in concretes exposed to such environments using an extensive suite of laboratory tests.

In Ireland, up to €5.8bn will be invested to provide fresh drinking water and …


The Influence Of Different European Cements On The Transport And Early-Age Properties Of Concrete In The Cover-Zone, Niall Holmes, L. Basheer, S. Nanukuttan, Pam. Basheer, W. J. Carter, T. M. Chrisp, G. Starrs Nov 2010

The Influence Of Different European Cements On The Transport And Early-Age Properties Of Concrete In The Cover-Zone, Niall Holmes, L. Basheer, S. Nanukuttan, Pam. Basheer, W. J. Carter, T. M. Chrisp, G. Starrs

Conference papers

The use of in situ tests for performance based specification would require demonstration of their suitability to distinguish the quality of concrete. With the introduction of new European Standards for cements, this would mean concretes produced with these new cements should be classified for their quality using the performance tests. It is generally believed that transport properties of concrete are related to their durability and hence the measurement of these properties can form the basis of performance based specifications. This paper reports data indicating that transport properties measured at 28-days for concretes manufactured with different European cements and water-binder ratios …


Developments In Intelligent Monitoring Of Concrete Structures, T. M. Chrisp, G. Starrs, W. J. Mccarter, E. H. Owens, S. V. Nanukuttan, Niall Holmes, L. Basheer Jun 2010

Developments In Intelligent Monitoring Of Concrete Structures, T. M. Chrisp, G. Starrs, W. J. Mccarter, E. H. Owens, S. V. Nanukuttan, Niall Holmes, L. Basheer

Conference papers

Deterioration in concrete comprises an initiation period and a propagation period. The initiation period is characterised by changes that occur within the concrete in response to the exposure environment and continues until a stage is reached when damage begins to propagate. The propagation period begins at a point in time defined when a particular event occurs (e.g. loss of steel passivity due to chloride ingress) and continues until a specified limit state is reached. The initiation and propagation stages of a deterioration process result from a complex interaction of physical, chemical and electrochemical phenomena. Prediction of the field performance of …


The Use Of Novel Non-Destructive Methods For Quality Control And Performance Evaluation Of Concrete Structures, Sree Nanukuttan, Niall Holmes, Sudarsan Srininvasan, Lulu Basheer, Muhammed Basheer, John Mccarter, Gerry Starrs Jan 2010

The Use Of Novel Non-Destructive Methods For Quality Control And Performance Evaluation Of Concrete Structures, Sree Nanukuttan, Niall Holmes, Sudarsan Srininvasan, Lulu Basheer, Muhammed Basheer, John Mccarter, Gerry Starrs

Conference papers

Concrete cover provides the first line of defense against the ingress of many deleterious substances into the concrete. Therefore, a measure of its transport properties is vital in assessing its long term performance in a given exposure condition. In new structures the rate of ingress of the deleterious substances could be monitored using array of electrical sensors that are embedded in the cover concrete. For structures that are currently in service, tests can be performed by removing cores from the structure (lab based tests) or by using tests that can be performed on the surface (in situ tests). Results relating …


Developments In Monitoring Techniques For Durability Assessment Of Cover-Zone Concrete, W.J. Mccarter, T. M. Chrisp, G. Starrs, Niall Holmes, L. Basheer, M. Basheer, S. V. Nanukuttan Jan 2010

Developments In Monitoring Techniques For Durability Assessment Of Cover-Zone Concrete, W.J. Mccarter, T. M. Chrisp, G. Starrs, Niall Holmes, L. Basheer, M. Basheer, S. V. Nanukuttan

Conference papers

This paper outlines developments in the use of an embedded multi-electrode sensor to study the response of the cover-zone (surface 50mm) to the changing ambient environment. The sensor enables the measurement of the spatial and temporal distribution of the electrical properties of concrete and temperature within the cover-zone thereby allowing an integrated assessment of cover-zone concrete performance. Both laboratory and field results are presented to highlight the information that can be obtained from embedded sensors. When exposed to the natural environment, the temperature dependence of the electrical response is highlighted and standardization protocols are developed to account for this effect. …


Performance-Based Testing Methodology For Concrete Durability, Niall Holmes, P. A.Muhammed Basheer, Sreejith Nanukuttan, Lulu Basheer Jun 2009

Performance-Based Testing Methodology For Concrete Durability, Niall Holmes, P. A.Muhammed Basheer, Sreejith Nanukuttan, Lulu Basheer

Reports

This report presents an overview of performance based testing methodology for concrete durability and work currently underway jointly at Queens University Belfast and Heriot Watt University, Edinburgh, to undertake this research under a EPSRC funded project (EP/G02152X/1).

EN206-1 superseded BS 5328 on 1st December 2003 and allows designers and producers to use a wide range of cements and aggregate types for a variety of exposure conditions. In this new standard, the durability of concrete is specified in terms of the constituent materials of concrete, properties of fresh and hardened concrete, limitations for concrete composition, specification of concrete, delivery of …


Testing And Monitoring Concrete Using Novel Methods For Predicting Their Long Term Behaviour, Sreejith Nanukuttan, Lulu Basheer, Muhammed Basheer, Niall Holmes, John Mccarter, Malcolm Chrisp, Gerry Starrs May 2009

Testing And Monitoring Concrete Using Novel Methods For Predicting Their Long Term Behaviour, Sreejith Nanukuttan, Lulu Basheer, Muhammed Basheer, Niall Holmes, John Mccarter, Malcolm Chrisp, Gerry Starrs

Conference papers

It is widely recognised that durability of concrete depends on its transport properties, viz. absorption, diffusion and permeability. As concrete cover provides the first line of defence against the ingress of many deleterious substances into the concrete, a measure of its transport properties is vital in assessing its long term performance in the given exposure condition. In new structures the rate of ingress of the deleterious substances could be monitored using array of electrical sensors which are embedded in the cover concrete. For structures which are currently in service, two in situ permeability apparatuses, viz. Autoclam Permeability System (for measuring …