Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 6 of 6

Full-Text Articles in Bioimaging and Biomedical Optics

Association Between Left Ventricular Mechanics And Diffuse Myocardial Fibrosis In Patients With Repaired Tetralogy Of Fallot: A Cross-Sectional Study, Christopher M. Haggerty, Jonathan D. Suever, Arichanah Pulenthiran, Abba Mejia-Spiegeler, Gregory J. Wehner, Linyuan Jing, Richard J. Charnigo, Brandon K. Fornwalt, Mark A. Fogel Dec 2017

Association Between Left Ventricular Mechanics And Diffuse Myocardial Fibrosis In Patients With Repaired Tetralogy Of Fallot: A Cross-Sectional Study, Christopher M. Haggerty, Jonathan D. Suever, Arichanah Pulenthiran, Abba Mejia-Spiegeler, Gregory J. Wehner, Linyuan Jing, Richard J. Charnigo, Brandon K. Fornwalt, Mark A. Fogel

Biomedical Engineering Faculty Publications

Background: Patients with repaired tetralogy of Fallot (TOF) have progressive, adverse biventricular remodeling, leading to abnormal contractile mechanics. Defining the mechanisms underlying this dysfunction, such as diffuse myocardial fibrosis, may provide insights into poor long-term outcomes. We hypothesized that left ventricular (LV) diffuse fibrosis is related to impaired LV mechanics.

Methods: Patients with TOF were evaluated with cardiac magnetic resonance in which modified Look-Locker (MOLLI) T1-mapping and spiral cine Displacement encoding (DENSE) sequences were acquired at three LV short-axis positions. Linear mixed modeling was used to define the association between regional LV mechanics from DENSE based on regional T1-derived diffuse …


Ambulatory Systolic Blood Pressure And Obesity Are Independently Associated With Left Ventricular Hypertrophic Remodeling In Children, Linyuan Jing, Christopher D. Nevius, Cassi M. Friday, Jonathan D. Suever, Arichanah Pulenthiran, Abba Mejia-Spiegeler, H. Lester Kirchner, William J. Cochran, Gregory J. Wehner, Aftab S. Chishti, Christopher M. Haggerty, Brandon K. Fornwalt Nov 2017

Ambulatory Systolic Blood Pressure And Obesity Are Independently Associated With Left Ventricular Hypertrophic Remodeling In Children, Linyuan Jing, Christopher D. Nevius, Cassi M. Friday, Jonathan D. Suever, Arichanah Pulenthiran, Abba Mejia-Spiegeler, H. Lester Kirchner, William J. Cochran, Gregory J. Wehner, Aftab S. Chishti, Christopher M. Haggerty, Brandon K. Fornwalt

Biomedical Engineering Faculty Publications

Background: Children with obesity have hypertrophic cardiac remodeling. Hypertension is common in pediatric obesity, and may independently contribute to hypertrophy. We hypothesized that both the degree of obesity and ambulatory blood pressure (ABP) would independently associate with measures of hypertrophic cardiac remodeling in children.

Methods: Children, aged 8–17 years, prospectively underwent cardiovascular magnetic resonance (CMR) and ABP monitoring. Left ventricular (LV) mass indexed to height2.7(LVMI), myocardial thickness and end-diastolic volume were quantified from a 3D LV model reconstructed from cine balanced steady state free precession images. Categories of remodeling were determined based on cutoff values for LVMI and …


Optimal Hemoglobin Extinction Coefficient Data Set For Near-Infrared Spectroscopy, Yue Zhao, Lina Qiu, Yunlong Sun, Chong Huang, Ting Li Nov 2017

Optimal Hemoglobin Extinction Coefficient Data Set For Near-Infrared Spectroscopy, Yue Zhao, Lina Qiu, Yunlong Sun, Chong Huang, Ting Li

Biomedical Engineering Faculty Publications

Extinction coefficient (ε) is a critical parameter for quantification of oxy-, deoxy-, and total-hemoglobin concentrations (Δ[HbO2], Δ[Hb], Δ[tHb]) from optical measurements of Near-infrared spectroscopy (NIRS). There are several different ε data sets which were frequently used in NIRS quantification. A previous study reported that even a small variation in ε could cause a significant difference in hemodynamic measurements. Apparently the selection of an optimal ε data set is important for NIRS. We conducted oxygen-state-varied and blood-concentration-varied model experiments with 57 human blood samples to mimic tissue hemodynamic variations. Seven reported ε data sets were evaluated by comparisons between …


Diffuse Optical Measurements Of Head And Neck Tumor Hemodynamics For Early Prediction Of Chemoradiation Therapy Outcomes, Lixin Dong, Mahesh Kudrimoti, Daniel Irwin, Li Chen, Sameera Kumar, Yu Shang, Chong Huang, Ellis L. Johnson, Scott D. Stevens, Brent J. Shelton, Guoqiang Yu Aug 2016

Diffuse Optical Measurements Of Head And Neck Tumor Hemodynamics For Early Prediction Of Chemoradiation Therapy Outcomes, Lixin Dong, Mahesh Kudrimoti, Daniel Irwin, Li Chen, Sameera Kumar, Yu Shang, Chong Huang, Ellis L. Johnson, Scott D. Stevens, Brent J. Shelton, Guoqiang Yu

Biomedical Engineering Faculty Publications

This study used a hybrid near-infrared diffuse optical instrument to monitor tumor hemodynamic responses to chemoradiation therapy for early prediction of treatment outcomes in patients with head and neck cancer. Forty-seven patients were measured once per week to evaluate the hemodynamic status of clinically involved cervical lymph nodes as surrogates for the primary tumor response. Patients were classified into two groups: complete response (CR) (n = 29) and incomplete response (IR) (n = 18). Tumor hemodynamic responses were found to be associated with clinical outcomes (CR/IR), wherein the associations differed depending on human papillomavirus (HPV-16) status. In HPV-16 …


Low-Cost Compact Diffuse Speckle Contrast Flowmeter Using Small Laser Diode And Bare Charge-Coupled-Device, Chong Huang, Myeongsu Seong, Joshua Paul Morgan, Siavash Mazdeyasna, Jae Gwan Kim, Jeffrey Todd Hastings, Guoqiang Yu Aug 2016

Low-Cost Compact Diffuse Speckle Contrast Flowmeter Using Small Laser Diode And Bare Charge-Coupled-Device, Chong Huang, Myeongsu Seong, Joshua Paul Morgan, Siavash Mazdeyasna, Jae Gwan Kim, Jeffrey Todd Hastings, Guoqiang Yu

Biomedical Engineering Faculty Publications

We report a low-cost compact diffuse speckle contrast flowmeter (DSCF) consisting of a small laser diode and a bare charge-coupled-device (CCD) chip, which can be used for contact measurements of blood flow variations in relatively deep tissues (up to ∼8  mm). Measurements of large flow variations by the contact DSCF probe are compared to a noncontact CCD-based diffuse speckle contrast spectroscopy and a standard contact diffuse correlation spectroscopy in tissue phantoms and a human forearm. Bland–Altman analysis shows no significant bias with good limits of agreement among these measurements: 96.5% ± 2.2% (94.4% to 100.0%) in phantom experiments and 92.8% …


Recent Advances In Optical Spectroscopic And Imaging Methods For Medicine And Biology, Yu Shang, Zhiyu Qian, Rickson C. Mesquita, Mathieu Dehaes Jan 2016

Recent Advances In Optical Spectroscopic And Imaging Methods For Medicine And Biology, Yu Shang, Zhiyu Qian, Rickson C. Mesquita, Mathieu Dehaes

Biomedical Engineering Faculty Publications

No abstract provided.