Full-Text Articles in Biomedical Engineering and Bioengineering

Improving The Performance And Evaluation Of Computer-Assisted Semen Analysis, Ji-Won Choi May 2022

Improving The Performance And Evaluation Of Computer-Assisted Semen Analysis, Ji-Won Choi

Dissertations

Semen analysis is performed routinely in fertility clinics to analyze the quality of semen and sperm cells of male patients. The analysis is typically performed by trained technicians or by Computer-Assisted Semen Analysis (CASA) systems. Manual semen analysis performed by technicians is subjective, time-consuming, and laborious, and yet most fertility clinics perform semen analysis in this manner. CASA systems, which are designed to perform the same tasks automatically, have a considerable market share, yet many studies still express concerns about their accuracy and consistency. In this dissertation, the focus is on detection, tracking, and classification of sperm cells in semen …


Mixed-Reality Visualization Environments To Facilitate Ultrasound-Guided Vascular Access, Leah Groves Sep 2021

Mixed-Reality Visualization Environments To Facilitate Ultrasound-Guided Vascular Access, Leah Groves

Electronic Thesis and Dissertation Repository

Ultrasound-guided needle insertions at the site of the internal jugular vein (IJV) are routinely performed to access the central venous system. Ultrasound-guided insertions maintain high rates of carotid artery puncture, as clinicians rely on 2D information to perform a 3D procedure. The limitations of 2D ultrasound-guidance motivated the research question: “Do 3D ultrasound-based environments improve IJV needle insertion accuracy”. We addressed this by developing advanced surgical navigation systems based on tracked surgical tools and ultrasound with various visualizations. The point-to-line ultrasound calibration enables the use of tracked ultrasound. We automated the fiducial localization required for this calibration method such that …


Optical Coherence Tomography Application To Alopecia In The Scalp, Elizabeth Melcher Jan 2018

Optical Coherence Tomography Application To Alopecia In The Scalp, Elizabeth Melcher

Research Opportunities for Engineering Undergraduates (ROEU) Program 2017-18

Alopecia is the loss of hair, whether it be from the scalp or other regions of the body. Current techniques used to best diagnose and track alopecia are often invasive, requiring a biopsy for results. The use of the OCT, or optical coherence tomography, could drastically improve a patient’s experience in undergoing a diagnosis while proving accurate results. The objective of this study is to develop diagnostic algorithms for the rapid, non-invasive diagnosis of alopecia with OCT. The first step is collecting OCT images of a healthy scalp to understand the anatomical structures with the imaging technique.


Skin Tone Tracking Device (Chromaband), Ziyang Bian Jun 2017

Skin Tone Tracking Device (Chromaband), Ziyang Bian

Computer Engineering

It’s long been said that your skin is a window into your health and with many illnesses the first signs of trouble actually show up in your skin. So if we have this natural warning system, then why isn’t anyone able to effectively use it to predict changes in our health? The problem is that currently there is no reliable way to accurately measure the change in skin tone and how these changes may or may not change with variations in health. This project’s aim is to design and develop a device that will record the changes in a user’s …


Detecting, Segmenting And Tracking Bio-Medical Objects, Mingzhong Li Jan 2016

Detecting, Segmenting And Tracking Bio-Medical Objects, Mingzhong Li

Doctoral Dissertations

"Studying the behavior patterns of biomedical objects helps scientists understand the underlying mechanisms. With computer vision techniques, automated monitoring can be implemented for efficient and effective analysis in biomedical studies. Promising applications have been carried out in various research topics, including insect group monitoring, malignant cell detection and segmentation, human organ segmentation and nano-particle tracking.

In general, applications of computer vision techniques in monitoring biomedical objects include the following stages: detection, segmentation and tracking. Challenges in each stage will potentially lead to unsatisfactory results of automated monitoring. These challenges include different foreground-background contrast, fast motion blur, clutter, object overlap and …


Real Time 3-D Tracking Of The High Dose Rate Radiation Source Using A Flat Panel Detector, Aditya Bondal Aug 2010

Real Time 3-D Tracking Of The High Dose Rate Radiation Source Using A Flat Panel Detector, Aditya Bondal

Theses and Dissertations

A number of QA procedures have been developed for Breast Brachytherapy treatments, yet none guarantee accurate dose delivery or allow conformation of the actual source position leading to errors sometimes going unnoticed. The objective of this study is to track the exact path the HDR source would follow in real time. The exit radiation of the HDR source was used to image a well defined matrix of markers. The images were acquired using FPD and were processed to obtain projection coordinates while an x-ray calibration image was processed to obtain marker coordinates. Each marker along with its projection represents a …