Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 7 of 7

Full-Text Articles in Biomedical Engineering and Bioengineering

Toxicity Evaluation Of Magnetic Hyperthermia Induced By Remote Actuation Of Magnetic Nanoparticles In 3d Micrometastasic Tumor Tissue Analogs For Triple Negative Breast Cancer, Nathanael A. Stocke, Pallavi Sethi, Amar Jyoti, Ryan Chan, Susanne M. Arnold, J. Zach Hilt, Meenakshi Upreti Mar 2017

Toxicity Evaluation Of Magnetic Hyperthermia Induced By Remote Actuation Of Magnetic Nanoparticles In 3d Micrometastasic Tumor Tissue Analogs For Triple Negative Breast Cancer, Nathanael A. Stocke, Pallavi Sethi, Amar Jyoti, Ryan Chan, Susanne M. Arnold, J. Zach Hilt, Meenakshi Upreti

Chemical and Materials Engineering Faculty Publications

Magnetic hyperthermia as a treatment modality is acquiring increased recognition for loco-regional therapy of primary and metastatic lung malignancies by pulmonary delivery of magnetic nanoparticles (MNP). The unique characteristic of magnetic nanoparticles to induce localized hyperthermia in the presence of an alternating magnetic field (AMF) allows for preferential killing of cells at the tumor site. In this study we demonstrate the effect of hyperthermia induced by low and high dose of MNP under the influence of an AMF using 3D tumor tissue analogs (TTA) representing the micrometastatic, perfusion independent stage of triple negative breast cancer (TNBC) that infiltrates the lungs. …


3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner Jul 2015

3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner

Richard A. Malthaner

The purpose of this study was to validate the accuracy and reliability of volume measurements obtained using three-dimensional (3D) thoracoscopic ultrasound (US) imaging. Artificial "tumours" were created by injecting a liquid agar mixture into spherical moulds of known volume. Once solidified, the "tumours" were implanted into the lung tissue in both a porcine lung sample ex vivo and a surgical porcine model in vivo. 3D US images were created by mechanically rotating the thoracoscopic ultrasound probe about its long axis while the transducer was maintained in close contact with the tissue. Volume measurements were made by one observer using the …


3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner Jul 2015

3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner

Richard A. Malthaner

The purpose of this study was to validate the accuracy and reliability of volume measurements obtained using three-dimensional (3D) thoracoscopic ultrasound (US) imaging. Artificial "tumours" were created by injecting a liquid agar mixture into spherical moulds of known volume. Once solidified, the "tumours" were implanted into the lung tissue in both a porcine lung sample ex vivo and a surgical porcine model in vivo. 3D US images were created by mechanically rotating the thoracoscopic ultrasound probe about its long axis while the transducer was maintained in close contact with the tissue. Volume measurements were made by one observer using the …


The Use Of Ct Density Changes At Internal Tissue Interfaces To Correlate Internal Organ Motion With An External Surrogate, Stewart Gaede, Gregory Carnes, Edward Yu, Jake Van Dyk, Jerry Battista, Ting-Yim Lee Jan 2009

The Use Of Ct Density Changes At Internal Tissue Interfaces To Correlate Internal Organ Motion With An External Surrogate, Stewart Gaede, Gregory Carnes, Edward Yu, Jake Van Dyk, Jerry Battista, Ting-Yim Lee

Edward Yu

The purpose of this paper is to describe a non-invasive method to monitor the motion of internal organs affected by respiration without using external markers or spirometry, to test the correlation with external markers, and to calculate any time shift between the datasets. Ten lung cancer patients were CT scanned with a GE LightSpeed Plus 4-Slice CT scanner operating in a ciné mode. We retrospectively reconstructed the raw CT data to obtain consecutive 0.5 s reconstructions at 0.1 s intervals to increase image sampling. We defined regions of interest containing tissue interfaces, including tumour/lung interfaces that move due to breathing …


3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner Jan 2007

3d Thoracoscopic Ultrasound Volume Measurement Validation In An Ex Vivo And In Vivo Porcine Model Of Lung Tumours, V. Hornblower, E. Yu, A. Fenster, J. Battista, R. Malthaner

Edward Yu

The purpose of this study was to validate the accuracy and reliability of volume measurements obtained using three-dimensional (3D) thoracoscopic ultrasound (US) imaging. Artificial "tumours" were created by injecting a liquid agar mixture into spherical moulds of known volume. Once solidified, the "tumours" were implanted into the lung tissue in both a porcine lung sample ex vivo and a surgical porcine model in vivo. 3D US images were created by mechanically rotating the thoracoscopic ultrasound probe about its long axis while the transducer was maintained in close contact with the tissue. Volume measurements were made by one observer using the …


Planning Evaluation Of Radiotherapy For Complex Lung Cancer Cases Using Helical Tomotherapy, Tomas Kron, Grigor Grigorov, Edward Yu, Slav Yartsev, Jeff Chen, Eugene Wong, George Rodrigues, Kris Trenka, Terry Coad, Glenn Bauman, Jake Van Dyk Aug 2004

Planning Evaluation Of Radiotherapy For Complex Lung Cancer Cases Using Helical Tomotherapy, Tomas Kron, Grigor Grigorov, Edward Yu, Slav Yartsev, Jeff Chen, Eugene Wong, George Rodrigues, Kris Trenka, Terry Coad, Glenn Bauman, Jake Van Dyk

Edward Yu

Lung cancer treatment is one of the most challenging fields in radiotherapy. The aim of the present study was to investigate what role helical tomotherapy (HT), a novel approach to the delivery of highly conformal dose distributions using intensity-modulated radiation fan beams, can play in difficult cases with large target volumes typical for many of these patients. Tomotherapy plans were developed for 15 patients with stage III inoperable non-small-cell lung cancer. While not necessarily clinically indicated, elective nodal irradiation was included for all cases to create the most challenging scenarios with large target volumes. A 2 cm margin was used …


Computed Tomography To Assess Pulmonary Injury Associated With Concurrent Chemo-Radiotherapy For Inoperable Non-Small Cell Lung Cancer, Galit Aviram, Edward Yu, Patricia Tai, Michael Lefcoe Nov 2001

Computed Tomography To Assess Pulmonary Injury Associated With Concurrent Chemo-Radiotherapy For Inoperable Non-Small Cell Lung Cancer, Galit Aviram, Edward Yu, Patricia Tai, Michael Lefcoe

Edward Yu

OBJECTIVE: To characterize serial computed tomography (CT) findings of pulmonary injury after a uniform regimen of concurrent chemo-radiotherapy in inoperable non-small cell lung cancer, and to compare the radiation-induced lung toxicity with other concurrent chemo-radiation regimens. METHODS: Twenty-four patients with advanced non-small cell lung cancer received 2 induction cycles of cisplatin and vinblastine, followed by 2 further cycles of cisplatin and vinblastine, concurrent with 60 Gy radiation at 2 Gy per fraction. Radiation-induced lung injury in the acute and chronic phases was assessed by serial CT scans and compared with preradiation baseline scans. Acute radiation pneumonitis was evaluated using the …