Development Of Low Frequency Electron Paramagnetic Resonance Methods And Instrumentation For Biological Applications, Laura A. Buchanan
Development Of Low Frequency Electron Paramagnetic Resonance Methods And Instrumentation For Biological Applications, Laura A. Buchanan
Electronic Theses and Dissertations
EPR is a powerful biophysical tool that can be used to measure tumor physiology. With the addition of magnetic field gradients, the spectral properties of paramagnetic species can be mapped. To facilitate EPR imaging, methods and instrumentation at frequencies between 250 MHz and 1 GHz were developed.
At low spin concentrations, the rapid scan background signal is often many times larger than the EPR signal of interest. To help remove the background contribution, a data acquisition procedure that takes advantage of a cross-loop resonator and bipolar power supplies was developed at 250 MHz. In this procedure, two scans are collected. …
Characterization Of Low Density Intracranial Lesions Using Dual-Energy Computed Tomography, Jessica L. Nute
Characterization Of Low Density Intracranial Lesions Using Dual-Energy Computed Tomography, Jessica L. Nute
Dissertations & Theses (Open Access)
Calcific and hemorrhagic foci of susceptibility are frequently encountered on routine brain MR studies. Both etiologies cause variations in local magnetic field strength, leading to dark regions on the MR images that cannot be classified. Single-energy CT (SECT) can be used to identify lesions with attenuation over 100 HU as calcific, however lesions with lower attenuation cannot be reliably identified. While calcific lesions are unlikely to cause harm, hemorrhagic lesions carry a risk of subsequent intracranial bleeding; as such, identification of hemorrhage is vital in preventing the inappropriate use of anticoagulant medications in patients with hemorrhagic lesions.
Given there currently …
The Use Of Ct Density Changes At Internal Tissue Interfaces To Correlate Internal Organ Motion With An External Surrogate, Stewart Gaede, Gregory Carnes, Edward Yu, Jake Van Dyk, Jerry Battista, Ting-Yim Lee
The Use Of Ct Density Changes At Internal Tissue Interfaces To Correlate Internal Organ Motion With An External Surrogate, Stewart Gaede, Gregory Carnes, Edward Yu, Jake Van Dyk, Jerry Battista, Ting-Yim Lee
Edward Yu
The purpose of this paper is to describe a non-invasive method to monitor the motion of internal organs affected by respiration without using external markers or spirometry, to test the correlation with external markers, and to calculate any time shift between the datasets. Ten lung cancer patients were CT scanned with a GE LightSpeed Plus 4-Slice CT scanner operating in a ciné mode. We retrospectively reconstructed the raw CT data to obtain consecutive 0.5 s reconstructions at 0.1 s intervals to increase image sampling. We defined regions of interest containing tissue interfaces, including tumour/lung interfaces that move due to breathing …