Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
Articles 1 - 9 of 9
Full-Text Articles in Biomedical Engineering and Bioengineering
Cherenkov Excited Short-Wavelength Infrared Fluorescence Imaging In Vivo With External Beam Radiation, Xu Cao, Shudong Jiang, Mengyu Jeremy Jia, Jason R. Gunn, Tianshun Miao, Scott C. Davis, Petr Bruza, Brian W. Pogue
Cherenkov Excited Short-Wavelength Infrared Fluorescence Imaging In Vivo With External Beam Radiation, Xu Cao, Shudong Jiang, Mengyu Jeremy Jia, Jason R. Gunn, Tianshun Miao, Scott C. Davis, Petr Bruza, Brian W. Pogue
Dartmouth Scholarship
Cherenkov emission induced by external beam radiation therapy from a clinical linear accelerator (LINAC) can be used to excite phosphors deep in biological tissues. As with all luminescence imaging, there is a desire to minimize the spectral overlap between the excitation light and emission wavelengths, here between the Cherenkov and the phosphor. Cherenkov excited short-wavelength infrared (SWIR, 1000 to 1700 nm) fluorescence imaging has been demonstrated for the first time, using long Stokes-shift fluorophore PdSe quantum dots (QD) with nanosecond lifetime and an optimized SWIR detection. The 1 / λ2 intensity spectrum characteristic of Cherenkov emission leads to low overlap …
Review Of Methods For Intraoperative Margin Detection For Breast Conserving Surgery, Benjamin W. Maloney, David M. Mcclatchy, Brian W. Pogue, Keith D. Paulsen, Wendy A. Wells, Richard J. Barth
Review Of Methods For Intraoperative Margin Detection For Breast Conserving Surgery, Benjamin W. Maloney, David M. Mcclatchy, Brian W. Pogue, Keith D. Paulsen, Wendy A. Wells, Richard J. Barth
Dartmouth Scholarship
Breast conserving surgery (BCS) is an effective treatment for early-stage cancers as long as the margins of the resected tissue are free of disease according to consensus guidelines for patient management. However, 15% to 35% of patients undergo a second surgery since malignant cells are found close to or at the margins of the original resection specimen. This review highlights imaging approaches being investigated to reduce the rate of positive margins, and they are reviewed with the assumption that a new system would need high sensitivity near 95% and specificity near 85%. The problem appears to be twofold. The first …
Tissue Oxygen Saturation Predicts Response To Breast Cancer Neoadjuvant Chemotherapy Within 10 Days Of Treatment, Jeffrey M. Cochran, David R. Busch, Anais Leproux, Zheng Zhang, Thomas D. O'Sullivan, Albert E. Cerussi, Philip M. Carpenter, Rita S. Mehta, Darren Roblyer, Wei Yang, Keith D. Paulsen, Brian Pogue, Shudong Jiang, Peter A. Kaufman
Tissue Oxygen Saturation Predicts Response To Breast Cancer Neoadjuvant Chemotherapy Within 10 Days Of Treatment, Jeffrey M. Cochran, David R. Busch, Anais Leproux, Zheng Zhang, Thomas D. O'Sullivan, Albert E. Cerussi, Philip M. Carpenter, Rita S. Mehta, Darren Roblyer, Wei Yang, Keith D. Paulsen, Brian Pogue, Shudong Jiang, Peter A. Kaufman
Dartmouth Scholarship
Ideally, neoadjuvant chemotherapy (NAC) assessment should predict pathologic complete response (pCR), a surrogate clinical endpoint for 5-year survival, as early as possible during typical 3- to 6-month breast cancer treatments. We introduce and demonstrate an approach for predicting pCR within 10 days of initiating NAC. The method uses a bedside diffuse optical spectroscopic imaging (DOSI) technology and logistic regression modeling. Tumor and normal tissue physiological properties were measured longitudinally throughout the course of NAC in 33 patients enrolled in the American College of Radiology Imaging Network multicenter breast cancer DOSI trial (ACRIN-6691). An image analysis scheme, employing z-score normalization to …
Perspective Review Of What Is Needed For Molecular-Specific Fluorescence-Guided Surgery, Brian W. Pogue, Eben L. Rosenthal, Samuel Achilefu, Gooitzen M. Van Dam
Perspective Review Of What Is Needed For Molecular-Specific Fluorescence-Guided Surgery, Brian W. Pogue, Eben L. Rosenthal, Samuel Achilefu, Gooitzen M. Van Dam
Dartmouth Scholarship
Molecular image-guided surgery has the potential for translating the tools of molecular pathology to real-time guidance in surgery. As a whole, there are incredibly positive indicators of growth, including the first United States Food and Drug Administration clearance of an enzyme-biosynthetic-activated probe for surgery guidance, and a growing number of companies producing agents and imaging systems. The strengths and opportunities must be continued but are hampered by important weaknesses and threats within the field. A key issue to solve is the inability of macroscopic imaging tools to resolve microscopic biological disease heterogeneity and the limitations in microscopic systems matching surgery …
Light Scattering Measured With Spatial Frequency Domain Imaging Can Predict Stromal Versus Epithelial Proportions In Surgically Resected Breast Tissue, David M. Mcclatchy, Elizabeth J. Rizzo, Wendy A. Wells, Candice C. Black, Keith D. Paulsen, Stephen C. Kanick, Brian W. Pogue
Light Scattering Measured With Spatial Frequency Domain Imaging Can Predict Stromal Versus Epithelial Proportions In Surgically Resected Breast Tissue, David M. Mcclatchy, Elizabeth J. Rizzo, Wendy A. Wells, Candice C. Black, Keith D. Paulsen, Stephen C. Kanick, Brian W. Pogue
Dartmouth Scholarship
This study aims to determine if light scatter parameters measured with spatial frequency domain imaging (SFDI) can accurately predict stromal, epithelial, and adipose fractions in freshly resected, unstained human breast specimens. An explicit model was developed to predict stromal, epithelial, and adipose fractions as a function of light scattering parameters, which was validated against a quantitative analysis of digitized histology slides for N = 31 specimens using leave-one-out cross-fold validation. Specimen mean stromal, epithelial, and adipose volume fractions predicted from light scattering parameters strongly correlated with those calculated from digitized histology slides (r = 0.90, 0.77, and 0.91, respectively, p-value× …
Correcting For Targeted And Control Agent Signal Differences In Paired-Agent Molecular Imaging Of Cancer Cell-Surface Receptors, Negar Sadeghipour, Scott C. Davis, Kenneth M. Tichauer
Correcting For Targeted And Control Agent Signal Differences In Paired-Agent Molecular Imaging Of Cancer Cell-Surface Receptors, Negar Sadeghipour, Scott C. Davis, Kenneth M. Tichauer
Dartmouth Scholarship
Paired-agent kinetic modeling protocols provide one means of estimating cancer cell-surface receptors with in vivo molecular imaging. The protocols employ the coadministration of a control imaging agent with one or more targeted imaging agent to account for the nonspecific uptake and retention of the targeted agent. These methods require the targeted and control agent data be converted to equivalent units of concentration, typically requiring specialized equipment and calibration, and/or complex algorithms that raise the barrier to adoption. This work evaluates a kinetic model capable of correcting for targeted and control agent signal differences. This approach was compared with an existing …
Radiotherapy-Induced Cherenkov Luminescence Imaging In A Human Body Phantom, Syed Rakin Ahmed, Mengyu Jia, Petr Bruza, Sergei A. Vinogradov, Shudong Jiang, David J. Gladstone, Lesley A. Jarvis, Brian W. Pogue
Radiotherapy-Induced Cherenkov Luminescence Imaging In A Human Body Phantom, Syed Rakin Ahmed, Mengyu Jia, Petr Bruza, Sergei A. Vinogradov, Shudong Jiang, David J. Gladstone, Lesley A. Jarvis, Brian W. Pogue
Dartmouth Scholarship
Radiation therapy produces Cherenkov optical emission in tissue, and this light can be utilized to activate molecular probes. The feasibility of sensing luminescence from a tissue molecular oxygen sensor from within a human body phantom was examined using the geometry of the axillary lymph node region. Detection of regions down to 30-mm deep was feasible with submillimeter spatial resolution with the total quantity of the phosphorescent sensor PtG4 near 1 nanomole. Radiation sheet scanning in an epi-illumination geometry provided optimal coverage, and maximum intensity projection images provided illustration of the concept. This work provides the preliminary information needed to attempt …
Optimal Wavelength Selection For Optical Spectroscopy Of Hemoglobin And Water Within A Simulated Light-Scattering Tissue, Mikael Marois, Stephen L. Jacques, Keith D. Paulsen
Optimal Wavelength Selection For Optical Spectroscopy Of Hemoglobin And Water Within A Simulated Light-Scattering Tissue, Mikael Marois, Stephen L. Jacques, Keith D. Paulsen
Dartmouth Scholarship
An algorithm that selects optimal wavelengths for spectral fitting of diffuse light reflectance spectra using a nonnegative least squares method is presented. Oxyhemoglobin, deoxyhemoglobin, and water are considered representative absorbers, but the approach is not constrained or limited by absorber selection provided native basis spectra are available. The method removes wavelengths iteratively from a scattering-modulated absorption matrix by maximizing the product of its singular values and offers considerable improvements over previously published wavelength selection schemes. Resulting wavelength selections are valid for a broad range of optical properties and yield lower RMS errors than other wavelength combinations. The method is easily …
Inhibition Of Apoptosis Exacerbates Fatigue-Damage Tendon Injuries In An In Vivo Rat Model, R. Bell, M. A. Robles-Harris, M. Anderson, D. Laudier, M. B. Schaffler, E. L. Flatow, N. Andarawis-Puri
Inhibition Of Apoptosis Exacerbates Fatigue-Damage Tendon Injuries In An In Vivo Rat Model, R. Bell, M. A. Robles-Harris, M. Anderson, D. Laudier, M. B. Schaffler, E. L. Flatow, N. Andarawis-Puri
Publications and Research
Tendinopathy is a common and progressive musculoskeletal disease. Increased apoptosis is an end-stage tendinopathy manifestation, but its contribution to the pathology of the disease is unknown. A previously established in vivo model of fatigue-damage accumulation shows that increased apoptosis is correlated with the severity of induced tendon damage, even in early onset of the disease, supporting its implication in the pathogenesis of the disease. Consequently, this study aimed to determine: (1) whether apoptosis could be inhibited after fatigue damage and (2) whether its inhibition could lead to remodeling of the extracellular matrix (ECM) and pericellular matrix (PCM), to ultimately improve …