Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 2 of 2

Full-Text Articles in Biomedical Engineering and Bioengineering

A Tunable, Three-Dimensional In Vitro Culture Model Of Growth Plate Cartilage Using Alginate Hydrogel Scaffolds, Alek G. Erickson, Taylor D. Laughlin, Sarah Romereim, Catherine Sargus-Patino, Angela K. Pannier, Andrew T. Dudley May 2017

A Tunable, Three-Dimensional In Vitro Culture Model Of Growth Plate Cartilage Using Alginate Hydrogel Scaffolds, Alek G. Erickson, Taylor D. Laughlin, Sarah Romereim, Catherine Sargus-Patino, Angela K. Pannier, Andrew T. Dudley

Biological Systems Engineering: Papers and Publications

Defining the final size and geometry of engineered tissues through precise control of the scalar and vector components of tissue growth is a necessary benchmark for regenerative medicine, but it has proved to be a significant challenge for tissue engineers. The growth plate cartilage that promotes elongation of the long bones is a good model system for studying morphogenetic mechanisms because cartilage is composed of a single cell type, the chondrocyte; chondrocytes are readily maintained in culture; and growth trajectory is predominately in a single vector. In this cartilage, growth is generated via a differentiation program that is spatially and …


A Comprehensive Dosimetric Study On Switching From A Type-B To A Type-C Dose Algorithm For Modern Lung Sbrt, Christina Zhou, Nathan Bennion, Rongtao Ma, Xiaoying Liang, Shuo Wang, Kristina Zvolanek, Megan Hyun, Xiaobo Li, Sumin Zhou, Weining Zhen, Chi Lin, Andrew Wahl, Dandan Zheng Jan 2017

A Comprehensive Dosimetric Study On Switching From A Type-B To A Type-C Dose Algorithm For Modern Lung Sbrt, Christina Zhou, Nathan Bennion, Rongtao Ma, Xiaoying Liang, Shuo Wang, Kristina Zvolanek, Megan Hyun, Xiaobo Li, Sumin Zhou, Weining Zhen, Chi Lin, Andrew Wahl, Dandan Zheng

Biological Systems Engineering: Papers and Publications

Background: Type-C dose algorithms provide more accurate dosimetry for lung SBRT treatment planning. However, because current dosimetric protocols were developed based on conventional algorithms, its applicability for the new generation algorithms needs to be determined. Previous studies on this issue used small sample sizes and reached discordant conclusions. Our study assessed dose calculation of a Type-C algorithm with current dosimetric protocols in a large patient cohort, in order to demonstrate the dosimetric impacts and necessary treatment planning steps of switching from a Type-B to a Type-C dose algorithm for lung SBRT planning.

Methods: Fifty-two lung SBRT patients were included, each …