Human Liver Sinusoid On A Chip For Hepatitis B Virus Replication Study, Young Bok (Abraham) Kang, Siddhartha Rawat, Nicholas Duchemin, Michael Bouchard, Moses Noh Jan 2017

Human Liver Sinusoid On A Chip For Hepatitis B Virus Replication Study, Young Bok (Abraham) Kang, Siddhartha Rawat, Nicholas Duchemin, Michael Bouchard, Moses Noh

Faculty Publications - Biomedical, Mechanical, and Civil Engineering

We have developed a miniature human liver (liver-sinusoid-on-a-chip) model using a dual microchannel separated by a porous membrane. Primary human hepatocytes and immortalized bovine aortic endothelial cells were co-cultured on opposite sides of a microporous membrane in a dual microchannel with continuous perfusion. Primary human hepatocytes in this system retained their polygonal morphology for up to 26 days, while hepatocytes cultured in the absence of bovine aortic endothelial cells lost their morphology within a week. In order to demonstrate the utility of our human-liver-sinusoid-on-a-chip, human hepatocytes in this system were directly infected by Hepatitis B Virus (HBV). Expression of the …