Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 9 of 9

Full-Text Articles in Biomedical Engineering and Bioengineering

Image Registration Of Ex-Vivo Mri To Sparsely Sectioned Histology Of Hippocampal And Neocortical Temporal Lobe Specimens., Maged Goubran, Cathie Crukley, Sandrine De Ribaupierre, Terence M Peters, Ali R Khan Dec 2013

Image Registration Of Ex-Vivo Mri To Sparsely Sectioned Histology Of Hippocampal And Neocortical Temporal Lobe Specimens., Maged Goubran, Cathie Crukley, Sandrine De Ribaupierre, Terence M Peters, Ali R Khan

Robarts Imaging Publications

Intractable or drug-resistant epilepsy occurs in up to 30% of epilepsy patients, with many of these patients undergoing surgical excision of the affected brain region to achieve seizure control. Recent magnetic resonance imaging (MRI) sequences and analysis techniques have the potential to detect abnormalities not identified with diagnostic MRI protocols. Prospective studies involving pre-operative imaging and collection of surgically-resected tissue provide a unique opportunity for verification and tuning of these image analysis techniques, since direct comparison can be made against histopathology, and can lead to better prediction of surgical outcomes and potentially less invasive procedures. To carry out MRI and …


Web-Based Simulation And Training Environment For Laparoscopic Camera Calibration, Kartik Thakore Oct 2013

Web-Based Simulation And Training Environment For Laparoscopic Camera Calibration, Kartik Thakore

Electronic Thesis and Dissertation Repository

Endoscopic cameras are increasingly employed in image-guidance procedures, where the video images must be registered to data from other modalities. However, such cameras are susceptible to distortions, requiring calibration before images can be used for registration, tracking and 3D reconstruction. Camera calibration is learned in a laboratory setting, where configuring and adjusting the physical setup is tedious and not necessarily conducive to learning. A centralized resource that utilizes 3D interactive components needs to be available for training on camera calibration. In this project, a web-based training environment for camera calibration is implemented called SimCAM. SimCAM was developed using the Web …


Fabricating Cost-Effective Nanostructures For Biomedical Applications, Erden Ertorer Sep 2013

Fabricating Cost-Effective Nanostructures For Biomedical Applications, Erden Ertorer

Electronic Thesis and Dissertation Repository

In this thesis we described inexpensive alternatives to fabricate nanostructures on planar substrates and provided example applications to discuss the efficiency of fabricated nanostructures.

The first method we described is forming large area systematically changing multi-shape nanoscale structures on a chip by laser interference lithography. We analyzed the fabricated structures at different substrate positions with respect to exposure time, exposure angle and associated light intensity profile. We presented experimental details related to the fabrication of symmetric and biaxial periodic nanostructures on photoresist, silicon surfaces, and ion-milled glass substrates. Behavior of osteoblasts and osteoclasts on the nanostructures was investigated. These results …


Automated Segmentation Of Left And Right Ventricles In Mri And Classification Of The Myocarfium Abnormalities, Cyrus (Mohammad Saleh) Nambakhsh Sep 2013

Automated Segmentation Of Left And Right Ventricles In Mri And Classification Of The Myocarfium Abnormalities, Cyrus (Mohammad Saleh) Nambakhsh

Electronic Thesis and Dissertation Repository

A fundamental step in diagnosis of cardiovascular diseases, automated left and right ventricle (LV and RV) segmentation in cardiac magnetic resonance images (MRI) is still acknowledged to be a difficult problem. Although algorithms for LV segmentation do exist, they require either extensive training or intensive user inputs. RV segmentation in MRI has yet to be solved and is still acknowledged a completely unsolved problem because its shape is not symmetric and circular, its deformations are complex and varies extensively over the cardiac phases, and it includes papillary muscles. In this thesis, I investigate fast detection of the LV endo- and …


Vascular Segmentation Algorithms For Generating 3d Atherosclerotic Measurements, Eranga Ukwatta Aug 2013

Vascular Segmentation Algorithms For Generating 3d Atherosclerotic Measurements, Eranga Ukwatta

Electronic Thesis and Dissertation Repository

Atherosclerosis manifests as plaques within large arteries of the body and remains as a leading cause of mortality and morbidity in the world. Major cardiovascular events may occur in patients without known preexisting symptoms, thus it is important to monitor progression and regression of the plaque burden in the arteries for evaluating patient's response to therapy. In this dissertation, our main focus is quantification of plaque burden from the carotid and femoral arteries, which are major sites for plaque formation, and are straight forward to image noninvasively due to their superficial location. Recently, 3D measurements of plaque burden have shown …


Piv-Based Investigation Of Hemodynamic Factors In Diseased Carotid Artery Bifurcations With Varying Plaque Geometries, Sarah Kefayati Aug 2013

Piv-Based Investigation Of Hemodynamic Factors In Diseased Carotid Artery Bifurcations With Varying Plaque Geometries, Sarah Kefayati

Electronic Thesis and Dissertation Repository

Ischemic stroke is often a consequence of complications due to clot formation (i.e. thrombosis) at the site of an atherosclerotic plaque developed in the internal carotid artery. Hemodynamic factors, such as shear-stress forces and flow disturbances, can facilitate the key mechanisms of thrombosis. Atherosclerotic plaques can differ in the severity of stenosis (narrowing), in eccentricity (symmetry), as well as inclusion of ulceration (wall roughness). Therefore, in terms of clinical significance, it is important to investigate how the local hemodynamics of the carotid artery is mediated by the geometry of plaque. Knowledge of thrombosis-associated hemodynamics may provide a basis to introduce …


Numerical Investigation Of The Interdependence Between Humeral Implant Position And Bone Removal Amount For Total Elbow Arthroplasty, Alexander J. Heroux Aug 2013

Numerical Investigation Of The Interdependence Between Humeral Implant Position And Bone Removal Amount For Total Elbow Arthroplasty, Alexander J. Heroux

Electronic Thesis and Dissertation Repository

Total elbow arthroplasty is a surgical procedure used to replace an afflicted articulation with prosthetic joint components. A good alignment between the native and prosthetic flexion-extension axes of the elbow is required to preserve its functionality. However, this is often unobtainable because of the mismatch between humeral canal and implant stem geometries. To correct this, surgeons are often required to intraoperatively make error-prone decisions when determining an appropriate implant posture that minimizes the amount of cortical bone to be removed while maintaining the alignment between the two flexion-extension axes. To address this issue, the present study has developed computational tools …


Reproducibility Of Hyperpolarized Xenon-129 Magnetic Resonance Imaging, Nikhil Kanhere Jul 2013

Reproducibility Of Hyperpolarized Xenon-129 Magnetic Resonance Imaging, Nikhil Kanhere

Electronic Thesis and Dissertation Repository

Spirometry and plethysmography provide gold standard measurements of obstructive lung disease, although these are global measurements of lung function made at the mouth, of a highly regionally heterogeneous disease. Hyperpolarized 129Xe magnetic resonance imaging (MRI) is a non-invasive, non-radiation-based imaging tool for visualizing regional lung structure and function. However, the reproducibility of 129Xe MRI measurements has not yet been studied or determined. Hence, in this thesis, we evaluated the reproducibility of 129Xe MRI using quantitative measurements such as ventilation defect percent (VDP). We showed that 129Xe VDP had high intra-observer and inter-observer reproducibility for repeated scans …


On The Development Of A Dynamic Contrast-Enhanced Near-Infrared Technique To Measure Cerebral Blood Flow In The Neurocritical Care Unit, Jonathan T. Elliott May 2013

On The Development Of A Dynamic Contrast-Enhanced Near-Infrared Technique To Measure Cerebral Blood Flow In The Neurocritical Care Unit, Jonathan T. Elliott

Electronic Thesis and Dissertation Repository

A dynamic contrast-enhanced (DCE) near-infrared (NIR) method to measure cerebral blood flow (CBF) in the neurocritical care unit (NCU) is described. A primary concern in managing patients with acquired brain injury (ABI) is onset of delayed ischemic injury (DII) caused by complications during the days to weeks following the initial insult, resulting in reduced CBF and impaired oxygen delivery.

The development of a safe, portable, and quantitative DCE-NIR method for measuring CBF in NCU patients is addressed by focusing on four main areas: designing a clinically compatible instrument, developing an appropriate analytical framework, creating a relevant ABI animal model, and …