Full-Text Articles in Biomedical Engineering and Bioengineering

Piezoelectric Probes And Their Capacity To Monitor Time Varying Viscosity, Eman Ahmed Aug 2012

Piezoelectric Probes And Their Capacity To Monitor Time Varying Viscosity, Eman Ahmed

Theses and Dissertations

Real-time, bedside observation of patient clotting is essential in various surgeries in the operating room (OR), but specifically during cardiac surgeries. The objective of this thesis is to design and test a new piezoelectric device that can be used for viscoelasticity measurement with time as a Point of Care (POC) test. Slow turnaround times (TAT) of current methods to monitor blood viscoelastic changes in patients have led to excessive bleeding and the need for blood transfusions in many situations (Despotis et al, 1997). This study shows that the phase shift produced by a resonator sensor can be related to the …


Noninvasive Optical Quantification Of Absolute Blood Flow, Blood Oxygenation, And Oxygen Consumption Rate In Exercising Skeletal Muscle, Katelyn Gurley, Yu Shang, Guoqiang Yu Jul 2012

Noninvasive Optical Quantification Of Absolute Blood Flow, Blood Oxygenation, And Oxygen Consumption Rate In Exercising Skeletal Muscle, Katelyn Gurley, Yu Shang, Guoqiang Yu

Biomedical Engineering Faculty Publications

This study investigates a method using novel hybrid diffuse optical spectroscopies [near-infrared spectroscopy (NIRS) and diffuse correlation spectroscopy (DCS)] to obtain continuous, noninvasive measurement of absolute blood flow (BF), blood oxygenation, and oxygen consumption rate (V̇O2) in exercising skeletal muscle. Healthy subjects (n=9) performed a handgrip exercise to increase BF and V̇O2 in forearm flexor muscles, while a hybrid optical probe on the skin surface directly monitored oxy-, deoxy-, and total hemoglobin concentrations ([HbO2], [Hb], and THC), tissue oxygen saturation (StO2), relative BF (rBF), and relative oxygen …


Dc Dielectrophoretic Assisted Anti-Fouling Filtration System, Nathan M. Cohen Mar 2012

Dc Dielectrophoretic Assisted Anti-Fouling Filtration System, Nathan M. Cohen

Master's Theses

Filtration processes, whether on the microfluidic, clinical treatment systems, or industrial scale (e.g., point-of-care diagnostics, dialysis, and biopharmaceutical manufacturing, respectively), are often inseparable from membrane clogging (fouling). As a consequence, most, if not all, filtration systems require frequent maintenance to maintain functionality and efficiency. The thesis of this project hypothesizes that Dielectrophoresis can be combined with standard filtration to reduce filter fouling, extending membrane life, and enabling continuous operation. This project investigates a method to reduce fouling, add specificity and efficiency, and decrease the cost and challenge of filtration based biofluid separations.

To substantiate this thesis, we designed, fabricated, and …


An Empirical Method For Correcting The Detector Spectral Response In Energy-Resolved Ct, Taly Gilat Schmidt Feb 2012

An Empirical Method For Correcting The Detector Spectral Response In Energy-Resolved Ct, Taly Gilat Schmidt

Biomedical Engineering Faculty Research and Publications

Energy-resolving photon-counting detectors have the potential for improved material decomposition compared to dual-kVp approaches. However, material decomposition accuracy is limited by the nonideal spectral response of the detectors. This work proposes an empirical method for correcting the nonideal spectral response, including spectrum-tailing effects. Unlike previous correction methods which relied on synchrotron measurements, the proposed method can be performed on the scanner. The proposed method estimates a spectral-response matrix by performing x-ray projection measurements through a range of known thicknesses of two or more calibration materials. Once estimated, the spectral-response matrix is incorporated into conventional material decomposition algorithms. A simulation study …