Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

2012

University of Nevada, Las Vegas

Discipline
Keyword
Publication
Publication Type

Articles 1 - 6 of 6

Full-Text Articles in Biomedical Engineering and Bioengineering

The Design And Testing Of A Solar Autoclave With Broad Spectrum Sterilization Capabilities, Sarah S. Trabia Nov 2012

The Design And Testing Of A Solar Autoclave With Broad Spectrum Sterilization Capabilities, Sarah S. Trabia

Honors College Theses

Energy is difficult to come by in developing countries and this interferes with the ability of doctors to provide good healthcare to their patients. Without decent sterilization, patients can become infected and diseases can spread throughout hospitals. This study involves designing a solar autoclave for developing countries that is as efficient as electrical autoclaves. The design is intended to not require any electrical input and to be affordable to those who cannot afford advanced medical equipment. Once the solar autoclave is designed, it will be tested to determine if it can sterilize equipment against a variety of different bacteria, including …


A Refreshable And Portable E-Braille System For The Blind And Visually Impaired, Mohammad Yousef Saadeh May 2012

A Refreshable And Portable E-Braille System For The Blind And Visually Impaired, Mohammad Yousef Saadeh

UNLV Theses, Dissertations, Professional Papers, and Capstones

The objective of this research is to design an affordable Braille tactile display that is wearable, refreshable, and portable. The device is intended to be used as an output device that can playback stored media. It can be also incorporated with current Braille reading technologies. The device will control both the electrical and mechanical stimulations to optimize the sensation and ensure extended use of the device. This work is concerned mainly with the mechanical aspects of the design.

This research proposed the development of a finger-wearable, scanning-style electric stimulation based (electrotactile) Braille display with sensing and adaptive rendering/actuation functions for …


The Use Of A Pylon Mounted Transducer For Investigating The Gait Of Transtibial Amputees, Justin Robert Brink May 2012

The Use Of A Pylon Mounted Transducer For Investigating The Gait Of Transtibial Amputees, Justin Robert Brink

UNLV Theses, Dissertations, Professional Papers, and Capstones

Two areas of research interest in the design and use of lower limb prosthetic devices are how foot performance varies with design and how prosthesis alignment affects gait. The current study addressed both of these areas through the use of the JR3 triaxial transducer mounted at the base of the socket. The transducer is an innovative form of instrumentation that measures forces and moments at the end of the socket. Traditional measurement of gait uses a force plate buried in the floor of a gait laboratory. The study established that the transducer offers a viable means of instrumentation for amputee …


Electrical & Magnetic Stimulation And Health, Yiyan Li Apr 2012

Electrical & Magnetic Stimulation And Health, Yiyan Li

College of Engineering: Graduate Celebration Programs

1, Introduction Most of the patients with neural diseases such as Parkinson’s disease, Stroke and Depression, cannot be cured by taking pills or conducting surgery. In contrast to the conventional therapies, physical therapies such as TMS (transcranial magnetic stimulation) (Fig. 1) and tDCS (transcranial direct current stimulation) (Fig. 2) are the most popular methods in treating neural disorders with a non-invasive way. TMS employs electromagnetic (1-3 Tesla) induction generates an Electric field suitable for neural stimulation; tDCS employs a weak current (1-2 mA) to modulate neuronal excitabilities.


Real-Time Face Detection And Recognition, Parker Hill, Brendan Morris Apr 2012

Real-Time Face Detection And Recognition, Parker Hill, Brendan Morris

College of Engineering: Graduate Celebration Programs

The face has become a popular biometric for identification due to the wide range of features and difficulty in manipulation of the metric. In order to work towards a robust facial recognition system, this work contains a foundation for using the face as a recognition metric. First, faces are detected from still images using a Viola-Jones object detection algorithm. Then, Eigenfaces is applied to the detected faces. The system was tested on face databases as well as real-time feed from a web camera.


Assessing The Therapeutic Effect Of 630 Nm Light-Emitting Diodes Irradiation On The Recovery Of Exercise-Induced Hand Muscle Fatigue With Surface Electromyogram, Dandan Yang, Xiaoying Wu, Wensheng Hou, Xiaolin Zheng, Jun Zheng, Yingtao Jiang Jan 2012

Assessing The Therapeutic Effect Of 630 Nm Light-Emitting Diodes Irradiation On The Recovery Of Exercise-Induced Hand Muscle Fatigue With Surface Electromyogram, Dandan Yang, Xiaoying Wu, Wensheng Hou, Xiaolin Zheng, Jun Zheng, Yingtao Jiang

Electrical & Computer Engineering Faculty Research

This paper aims to investigate the effect of light emitting diode therapy (LEDT) on exercise-induced hand muscle fatigue by measuring the surface electromyography (sEMG) of flexor digitorum superficialis. Ten healthy volunteers were randomly placed in the equal sized LEDT group and control group. All subjects performed a sustained fatiguing isometric contraction with the combination of four fingertips except thumb at 30% of maximal voluntary contraction (MVC) until exhaustion. The active LEDT or an identical passive rest therapy was then applied to flexor digitorum superficialis. Each subject was required to perform a re-fatigue task immediately after therapy which was the same …