Open Access. Powered by Scholars. Published by Universities.®
Biomedical Engineering and Bioengineering Commons™
Open Access. Powered by Scholars. Published by Universities.®
- Institution
- Keyword
-
- Confocal microscopy (4)
- Epidermis - Imaging (4)
- Imaging (4)
- Imaging systems (4)
- Signal processing (4)
-
- Animals (3)
- Humans (3)
- Instrumentation (3)
- Tomography (3)
- Algorithms (2)
- Breast cancer (2)
- Confocal Microscope (2)
- Diagnosis (2)
- Epidermis (2)
- Equipment design (2)
- Equipment failure analysis (2)
- FDTD (2)
- Female (2)
- Filtering (2)
- Fluorescence (2)
- Image filtering (2)
- Image processing (2)
- Image quality (2)
- Image registration (2)
- Image restoration (2)
- In vivo (2)
- Inhomogeneity (2)
- Lawrencium (2)
- Magnetic Resonance Imaging (2)
- Medical imaging (2)
- Publication
-
- Dartmouth Scholarship (4)
- Electronic Thesis and Dissertation Repository (4)
- Charles A. DiMarzio (3)
- Biomedical Engineering (2)
- Department of Agricultural and Biological Systems Engineering: Dissertations, Theses, and Student Research (2)
-
- Electrical & Computer Engineering Faculty Publications (2)
- Carey Rappaport (1)
- Dana Brooks (1)
- Department of Engineering Mechanics: Dissertations, Theses, and Student Research (1)
- Doctoral Dissertations (1)
- Honors Theses (1)
- Kyuwan Lee (1)
- Masters Theses 1911 - February 2014 (1)
- Miriam Leeser (1)
- Neuroscience Faculty Publications (1)
- Physiology and Pharmacology Publications (1)
- Radiology Faculty Publications (1)
- Sarah Englander (1)
- Theses and Dissertations--Biomedical Engineering (1)
- Publication Type
- File Type
Articles 1 - 30 of 30
Full-Text Articles in Biomedical Engineering and Bioengineering
Correct Spectral Conversion Between Surface‐Enhanced Raman And Plasmon Resonance Scattering From Nanoparticle Dimers For Single‐Molecule Detection, Kyuwan Lee
Kyuwan Lee
Simultaneous measurement of surface-enhanced Raman scattering (SERS) and localized surface plasmon resonance (LSPR) in nanoparticle dimers presents outstanding opportunities in molecular identification and in the elucidation of physical properties, such as the size, distance, and deformation of target species. SERS–LSPR instrumentation exists and has been used under limited conditions, but the extraction of SERS and LSPR readouts from a single measurement is still a challenge. Herein, the extraction of LSPR spectra from SERS signals is reported and a tool for measuring the interparticle distance from Raman enhancement data by the standardization of the SERS signal is proposed. The SERS nanoruler …
Morphometric, Biochemical, And Raman Spectral Analyses Of Muscle Damage In Patients With Peripheral Arterial Disease: Providing Objective Criteria For Diagnosis And Treatment Monitoring, Kim Cluff
Department of Agricultural and Biological Systems Engineering: Dissertations, Theses, and Student Research
Peripheral arterial disease (PAD), which affects approximately 10 million Americans, is characterized by atherosclerosis of the non-coronary arteries. PAD produces a progressive accumulation of ischemic injury to the limbs that is reflected in a gradual worsening in the myofiber morphology and oxidative damage in the gastrocnemius muscle. In this study, we evaluated the hypothesis that quantitative morphological and biochemical parameters of gastrocnemius myofibers change in a consistent manner during the progression of PAD, provide an objective grading of muscle degeneration in the ischemic limb, and correlate to clinical stage of PAD. Myofiber morphometrics were determined precisely with mathematical equations that …
Implementation Of Magnetic Resonance Elastography For The Investigation Of Traumatic Brain Injuries, Thomas Boulet
Implementation Of Magnetic Resonance Elastography For The Investigation Of Traumatic Brain Injuries, Thomas Boulet
Department of Engineering Mechanics: Dissertations, Theses, and Student Research
Magnetic resonance elastography (MRE) is a potentially transformative imaging modality allowing local and non-invasive measurement of biological tissue mechanical properties. It uses a specific phase contrast MR pulse sequence to measure induced vibratory motion in soft material, from which material properties can be estimated. Compared to other imaging techniques, MRE is able to detect tissue pathology at early stages by quantifying the changes in tissue stiffness associated with diseases. In an effort to develop the technique and improve its capabilities, two inversion algorithms were written to evaluate viscoelastic properties from the measured displacements fields. The first one was based on …
Geometrical Analysis And Modeling Of Craniosynostosis, Sahar Shahbazi
Geometrical Analysis And Modeling Of Craniosynostosis, Sahar Shahbazi
Electronic Thesis and Dissertation Repository
Craniosynostosis is a developmental abnormality in skull growth, due to the fusion of one or more sutures\cite{patho}. To accommodate the growing brain. the skull needs to grow quickly in the first few months of life, and most of the growth of the skull at that time occurs at the sutures. Craniosynostosis occurs when one or more sutures are fused in utero, resulting in an abnormal skull shape. Surgical intervention is usually required at a young age, and remodeling of the skull is done for cosmetic reasons as well as to avoid raised intracranial pressure. In order to study how the …
Quantitative, Spectrally-Resolved Intraoperative Fluorescence Imaging, Pablo A. Valdés, Frederic Leblond, Valerie L. Jacobs, Brian C. Wilson, Keith D. Paulsen, David W. Roberts
Quantitative, Spectrally-Resolved Intraoperative Fluorescence Imaging, Pablo A. Valdés, Frederic Leblond, Valerie L. Jacobs, Brian C. Wilson, Keith D. Paulsen, David W. Roberts
Dartmouth Scholarship
Intraoperative visual fluorescence imaging (vFI) has emerged as a promising aid to surgical guidance, but does not fully exploit the potential of the fluorescent agents that are currently available. Here, we introduce a quantitative fluorescence imaging (qFI) approach that converts spectrally-resolved data into images of absolute fluorophore concentration pixel-by-pixel across the surgical field of view (FOV). The resulting estimates are linear, accurate, and precise relative to true values, and spectral decomposition of multiple fluorophores is also achieved. Experiments with protoporphyrin IX in a glioma rodent model demonstrate in vivo quantitative and spectrally-resolved fluorescence imaging of infiltrating tumor margins for the …
Metrics For Evaluating Surgical Microscope Usage During Myringotomy, Arefin M. Shamsil
Metrics For Evaluating Surgical Microscope Usage During Myringotomy, Arefin M. Shamsil
Electronic Thesis and Dissertation Repository
Abstract
Although teaching and learning surgical microscope manoeuvring is a fundamental step in middle ear surgical training, currently there is no objective method to teach or assess this skill. This thesis presents an experimental study designed to implement and test sets of metrics capable of numerically evaluating microscope manoeuvrability and qualitatively assessing surgical expertise of a subject during a middle ear surgery called myringotomy. The experiment involved performing a myringotomy on a fixed cadaveric ear. As participants, experienced ear-nose-throat (ENT) surgeons and ENT surgical residents were invited. While performing the procedure, their microscope manoeuvring motions were captured as translational and …
A Digital X-Ray Tomosynthesis Coupled Near Infrared Spectral Tomography System For Dual-Modality Breast Imaging, Venkataramanan Krishnaswamy, Kelly E. Michaelsen, Brian W. Pogue, Steven P. Poplack, Ian Shaw, Ken Defrietas, Ken Brooks, Keith D. Paulsen
A Digital X-Ray Tomosynthesis Coupled Near Infrared Spectral Tomography System For Dual-Modality Breast Imaging, Venkataramanan Krishnaswamy, Kelly E. Michaelsen, Brian W. Pogue, Steven P. Poplack, Ian Shaw, Ken Defrietas, Ken Brooks, Keith D. Paulsen
Dartmouth Scholarship
A Near Infrared Spectral Tomography (NIRST) system has been developed and integrated into a commercial Digital Breast Tomosynthesis (DBT) scanner to allow structural and functional imaging of breast in vivo. The NIRST instrument uses an 8-wavelength continuous wave (CW) laser-based scanning source assembly and a 75-element silicon photodiode solid-state detector panel to produce dense spectral and spatial projection data from which spectrally constrained 3D tomographic images of tissue chromophores are produced. Integration of the optical imaging system into the DBT scanner allows direct co-registration of the optical and DBT images, while also facilitating the synergistic use of x-ray contrast as …
Measurement Of The Oxidation State Of Mitochondrial Cytochrome C From The Neocortex Of The Mammalian Brain, Y. Sakata, M. Abajian, M. O. Ripple, R. Springett
Measurement Of The Oxidation State Of Mitochondrial Cytochrome C From The Neocortex Of The Mammalian Brain, Y. Sakata, M. Abajian, M. O. Ripple, R. Springett
Dartmouth Scholarship
Diffuse optical remission spectra from the mammalian neocortex at visible wavelengths contain spectral features originating from the mitochondria. A new algorithm is presented, based on analytically relating the first differential of the attenuation spectrum to the first differential of the chromophore spectra, that can separate and calculate the oxidation state of cytochrome c as well as the absolute concentration and saturation of hemoglobin. The algorithm is validated in phantoms and then tested on the neocortex of the rat during an anoxic challenge. Implementation of the algorithm will provide detailed information of mitochondrial oxygenation and mitochondrial function in physiological studies of …
Two-Dimensional Blood Flow Velocity Estimation Using Ultrasound Speckle Pattern Dependence On Scan Direction And Velocity, Tiantian Xu
Department of Agricultural and Biological Systems Engineering: Dissertations, Theses, and Student Research
Cardiovascular disease is the leading cause death in the United States. Although emergency surgery and medicine can be used for cardiovascular disease treatment, the survivors will suffer for it afterwards. Ultrasound blood flow measurement provides a noninvasive way for cardiovascular diseases diagnosis. In this dissertation, three algorithms for blood flow velocity measurements were investigated and optimized. Feature tracking has been previously proposed for vector velocity measurement. In Chapter 3, the optimal amplitude and time thresholds for feature extraction were investigated to minimize flow estimate variance while providing sufficient spatial and temporal coverage of flow area. A new method of lateral …
Augmented Image-Guidance For Transcatheter Aortic Valve Implantation, Pencilla Lang
Augmented Image-Guidance For Transcatheter Aortic Valve Implantation, Pencilla Lang
Electronic Thesis and Dissertation Repository
The introduction of transcatheter aortic valve implantation (TAVI), an innovative stent-based technique for delivery of a bioprosthetic valve, has resulted in a paradigm shift in treatment options for elderly patients with aortic stenosis. While there have been major advancements in valve design and access routes, TAVI still relies largely on single-plane fluoroscopy for intraoperative navigation and guidance, which provides only gross imaging of anatomical structures. Inadequate imaging leading to suboptimal valve positioning contributes to many of the early complications experienced by TAVI patients, including valve embolism, coronary ostia obstruction, paravalvular leak, heart block, and secondary nephrotoxicity from contrast use.
A …
Towards Omni-Tomography -- Grand Fusion Of Multiple Modalities For Simultaneous Interior Tomography, Ge Wang, Jie Zhang, Hao Gao, Victor Weir, Hengyong Yu, Wenxiang Cong, Xiaochen Xu, Haiou Shen, James Bennett, Mark Furth, Yue Wang, Michael Vannier
Towards Omni-Tomography -- Grand Fusion Of Multiple Modalities For Simultaneous Interior Tomography, Ge Wang, Jie Zhang, Hao Gao, Victor Weir, Hengyong Yu, Wenxiang Cong, Xiaochen Xu, Haiou Shen, James Bennett, Mark Furth, Yue Wang, Michael Vannier
Radiology Faculty Publications
We recently elevated interior tomography from its origin in computed tomography (CT) to a general tomographic principle, and proved its validity for other tomographic modalities including SPECT, MRI, and others. Here we propose "omni-tomography", a novel concept for the grand fusion of multiple tomographic modalities for simultaneous data acquisition in a region of interest (ROI). Omni-tomography can be instrumental when physiological processes under investigation are multi-dimensional, multi-scale, multi-temporal and multi-parametric. Both preclinical and clinical studies now depend on in vivo tomography, often requiring separate evaluations by different imaging modalities. Over the past decade, two approaches have been used for multimodality …
Coupling Of Audio Signals Into Afm Images, Matthew Manning
Coupling Of Audio Signals Into Afm Images, Matthew Manning
Honors Theses
It is well known that Atomic Force Microscopy imaging is capable of yielding high resolution results with of surfaces at the nanoscale. However, despite the device capabilities and vast applications, AFM microscopy is possibly the most prone to the creation of image artifacts. AFM imaging can easily, and is often, corrupted by various external forces. The most obvious and measurable form of external interference is of course the presence of ambient noise. Most AFM manufactures attempt to counter the effects of such noise on the imaging process through use of noise-proof or noise-resistant shields that cover the microscope aperture. Without …
Development Of A Blood Flow Measurement Protocol Using Particle Image Velocimetry, Jennifer Chi-Ying Go
Development Of A Blood Flow Measurement Protocol Using Particle Image Velocimetry, Jennifer Chi-Ying Go
Biomedical Engineering
Peripheral Arterial Occlusive Disease (PAOD) is an acquired inflammatory disease where a peripheral artery becomes occluded due to the buildup of atherosclerotic plaques. In patients that possess collateral arteries, an occlusion can lead to shear induced outward remodeling, arteriogenesis, of these collaterals, partially restoring blood flow. However, newly remodeled collaterals exhibit reduced functional vasodilation, which may impair normal activity, such as ambulation. To model chronic ischemia and arteriogenesis in collaterals, a femoral artery ligation in a murine hindlimb is commonly performed. Previous efforts by our group involved measurements of collateral artery diameter to assess the impact of arteriogenesis on functional …
Testing And Validation Of An Autostainer, Nicholas Hanne
Testing And Validation Of An Autostainer, Nicholas Hanne
Biomedical Engineering
Histology performed by Cal Poly students for research projects and labs are currently performed by hand using a dipping technique. This technique is time consuming, expensive, imprecise, and often unrepeatable. Central Coast Pathology donated a Dako Autostainer to the Biomedical Engineering Department that can perform immunohistological stains of up to 48 samples simultaneously using tightly controlled reagent volumes and incubation times. Protocols are programmed into the machine and can be repeated under the same conditions every time with minimal preparation and exposure to potentially dangerous reagents. The autostainer was repaired and validated by comparing PECAM & BBI stains performed on …
Resting-State Connectivity Identifies Distinct Functional Networks In Macaque Cingulate Cortex., R Matthew Hutchison, Thilo Womelsdorf, Joseph S Gati, L Stan Leung, Ravi S Menon, Stefan Everling
Resting-State Connectivity Identifies Distinct Functional Networks In Macaque Cingulate Cortex., R Matthew Hutchison, Thilo Womelsdorf, Joseph S Gati, L Stan Leung, Ravi S Menon, Stefan Everling
Physiology and Pharmacology Publications
Subregions of the cingulate cortex represent prominent intersections in the structural networks of the primate brain. The relevance of the cingulate to the structure and dynamics of large-scale networks ultimately requires a link to functional connectivity. Here, we map fine-grained functional connectivity across the complete extent of the macaque (Macaca fascicularis) cingulate cortex and delineate subdivisions pertaining to distinct identifiable networks. In particular, we identified 4 primary networks representing the functional spectrum of the cingulate: somatomotor, attention-orienting, executive, and limbic. The cingulate nodes of these networks originated from separable subfields along the rostral-to-caudal axis and were characterized by positive and …
Real-Time Prostate Motion Tracking For Robot-Assisted Laparoscopic Radical Prostatectomy, Mehdi Esteghamatian
Real-Time Prostate Motion Tracking For Robot-Assisted Laparoscopic Radical Prostatectomy, Mehdi Esteghamatian
Electronic Thesis and Dissertation Repository
Radical prostatectomy surgery (RP) is the gold standard for treatment of localized prostate cancer (PCa). Recently, emergence of minimally invasive techniques such as Laparoscopic Radical Prostatectomy (LRP) and Robot-Assisted Laparoscopic Radical Prostatectomy (RARP) has improved the outcomes for prostatectomy. However, it remains difficult for surgeons to make informed decisions regarding resection margins and nerve sparing since the location of the tumour within the organ is not usually visible in a laparoscopic view. While MRI enables visualization of the salient structures and cancer foci, its efficacy in LRP is reduced unless it is fused into a stereoscopic view such that homologous …
A Novel Imaging System For Automatic Real-Time 3d Patient-Specific Knee Model Reconstruction Using Ultrasound Rf Data, Rimon Adel Messiha Tadross
A Novel Imaging System For Automatic Real-Time 3d Patient-Specific Knee Model Reconstruction Using Ultrasound Rf Data, Rimon Adel Messiha Tadross
Doctoral Dissertations
This dissertation introduces a novel imaging method and system for automatic real-time 3D patient-specific knee model reconstruction using ultrasound RF data. The developed method uses ultrasound to transcutaneously digitize a point cloud representing the bone’s surface. This point cloud is then used to reconstruct 3D bone model using deformable models method.
In this work, three systems were developed for 3D knee bone model reconstruction using ultrasound RF data. The first system uses tracked single-element ultrasound transducer, and was experimented on 12 knee phantoms. An average reconstruction accuracy of 0.98 mm was obtained. The second system was developed using an ultrasound …
Hemodynamically Constrained Dynamic Diffuse Optical Tomography Under Mammographic Compression, Eleonora Vidolova, Dana H. Brooks, Eric L. Miller, Stefan Carp, David A. Boas
Hemodynamically Constrained Dynamic Diffuse Optical Tomography Under Mammographic Compression, Eleonora Vidolova, Dana H. Brooks, Eric L. Miller, Stefan Carp, David A. Boas
Dana Brooks
This poster considers these points: DOT taken along x-ray mammogram provide valuable functional information, X-ray mammography only gives structural information hard to distinguish between benign and malignant masses, Oxygen consumption (OC) and blood flow (F) contrasts observed between malignant and normal tissue[3, 4], Blood flow, oxygen saturation(SO2), water and lipid distributions could specify the degree of malignancy of a tumor, Physiological changes in the breast due to mammographic compression are significant and should be taken into account[2].
Fdtd Simulation Of A Confocal Microscope Using A Theta Line Scan, Blair Simon, Charles Dimarzio, Milind Rajadhyaksha, Carey Rappaport
Fdtd Simulation Of A Confocal Microscope Using A Theta Line Scan, Blair Simon, Charles Dimarzio, Milind Rajadhyaksha, Carey Rappaport
Carey Rappaport
We describe a 2-D computational model of the optical propagation in human skin from a confocal reflectance theta microscope. As an effect of decreasing the size of the microscope so that it is more clinically useful, the usual point source and detector with a raster scan is changed to a line source with a 1-D array detector. Because there is only one dimension of scanning, the microscope is confocal in one direction, but not in the other, however, this results in additional localized decreases in signal. We hypothesize that these result from the interaction of the bi-static imaging configuration with …
Field Programmable Gate Arrays To Accelerate Sub-Surface Imaging Problems, Miriam Leeser
Field Programmable Gate Arrays To Accelerate Sub-Surface Imaging Problems, Miriam Leeser
Miriam Leeser
No abstract provided.
Fdtd Simulation Of A Confocal Microscope Using A Theta Line Scan, Blair Simon, Charles Dimarzio, Milind Rajadhyaksha, Carey Rappaport
Fdtd Simulation Of A Confocal Microscope Using A Theta Line Scan, Blair Simon, Charles Dimarzio, Milind Rajadhyaksha, Carey Rappaport
Charles A. DiMarzio
We describe a 2-D computational model of the optical propagation in human skin from a confocal reflectance theta microscope. As an effect of decreasing the size of the microscope so that it is more clinically useful, the usual point source and detector with a raster scan is changed to a line source with a 1-D array detector. Because there is only one dimension of scanning, the microscope is confocal in one direction, but not in the other, however, this results in additional localized decreases in signal. We hypothesize that these result from the interaction of the bi-static imaging configuration with …
Photo-Thermal Coherent Confocal Microscope, Sean Sullivan, Charles Dimarzio
Photo-Thermal Coherent Confocal Microscope, Sean Sullivan, Charles Dimarzio
Charles A. DiMarzio
Confocal microscopy has been shown to be useful in imaging skin slightly below the junction of the dermis and epidermis. However, the depth of imaging is a significant limitation. We present a novel concept designed both to improve the depth of penetration and to increase the information content of images obtained with a reflectance confocal microscope. Using an approach similar to optoacoustics, we plan to explore the use of laser heating to generate tissue expansion, which will be measured by the microscope. The microscope will incorporate a pulsed heating laser along the same optical path as the imaging laser in …
Compact Dual Wedge Point Scanning Confocal Reflectance Microscope, William C. Warger Ii, Stephen A. Guerrera, Charles A. Dimarzio
Compact Dual Wedge Point Scanning Confocal Reflectance Microscope, William C. Warger Ii, Stephen A. Guerrera, Charles A. Dimarzio
Charles A. DiMarzio
Confocal reflectance microscopy has been shown to provide optical sectioning and resolution sufficient to provide useful information about skin to a depth below the epidermis. However, existing instruments are large and expensive, because of the need for fast twodimensional scanning in the pupil, and the associated relay optics. A more compact scanning system could lead to an affordable hand-held instrument for in vivo imaging. Several approaches are being considered with different advantages and disadvantages. Here we report one approach that incorporates a dual-wedge scanner within a point-scanning configuration. The dual-wedge scanner is implemented by replacing the two scanning mirrors and …
Quantitative Cherenkov Emission Spectroscopy For Tissue Oxygenation Assessment, Johan Axelsson, Adam K. Glaser, David J. Gladstone, Brian W. Pogue
Quantitative Cherenkov Emission Spectroscopy For Tissue Oxygenation Assessment, Johan Axelsson, Adam K. Glaser, David J. Gladstone, Brian W. Pogue
Dartmouth Scholarship
Measurements of Cherenkov emission in tissue during radiation therapy are shown to enable estimation of hemoglobin oxygen saturation non-invasively, through spectral fitting of the spontaneous emissions from the treated tissue. Tissue oxygenation plays a critical role in the efficacy of radiation therapy to kill tumor tissue. Yet in-vivo measurement of this has remained elusive in routine use because of the complexity of oxygen measurement techniques. There is a spectrally broad emission of Cherenkov light that is induced during the time of irradiation, and as this travels through tissue from the point of the radiation deposition, the tissue absorption and scatter …
Simultaneous Estimation And Segmentation Of T1 Map For Breast Parenchyma Measurement, Ye Xing, Yangming Ou, Sarah Englander, Mitchell D. Schnall, Dinggang Shen
Simultaneous Estimation And Segmentation Of T1 Map For Breast Parenchyma Measurement, Ye Xing, Yangming Ou, Sarah Englander, Mitchell D. Schnall, Dinggang Shen
Sarah Englander
Breast density has been shown to be an independent risk factor for breast cancer. In order to segment breast parenchyma, which has been proposed as a biomarker of breast cancer risk, we present an integrated algorithm for simultaneous T1 map estimation and segmentation, using a series of magnetic resonance (MR) breast images. The advantage of using this algorithm is that the step of T1 map estimation (E-Step) and the step of T1 map based tissue segmentation (S-Step) can benefit each other. Since the estimated T1 map can be noisy due to the complexity of T1 estimation method, the tentative tissue …
Terahertz Imaging For Cancer Detection, Benjamin A. St. Peter
Terahertz Imaging For Cancer Detection, Benjamin A. St. Peter
Masters Theses 1911 - February 2014
This project evaluates the ability of terahertz (THz) radiation to differentiate cancerous from non-cancerous human breast lumpectomy and mastectomy tissue. This is done by aiming a narrow-band THz beam at medical samples and measuring reflected power. THz images of specimens from Breast Conservation Surgery (BCS) were created using a gas laser source and mechanical scanning. The design and characterization of this system is discussed in detail. The images were correlated with optical histological micrographs of the same specimens and discrimination values of more than 70% were found for five of the six samples using Receiver Operating Characteristic (ROC) analysis.
Use Of Hybrid Diffuse Optical Spectroscopies In Continuous Monitoring Of Blood Flow, Blood Oxygenation, And Oxygen Consumption Rate In Exercising Skeletal Muscle, Katelyn Gurley
Theses and Dissertations--Biomedical Engineering
This study combines noninvasive hybrid diffuse optical spectroscopies [near-infrared spectroscopy (NIRS) and diffuse correlation spectroscopy (DCS)] with occlusive calibration for continuous measurement of absolute blood flow (BF), tissue blood oxygenation (StO2), and oxygen consumption rate (VO2) in exercising skeletal muscle. Subjects performed rhythmic dynamic handgrip exercise, while an optical probe connected to a hybrid NIRS/DCS flow-oximeter directly monitored oxy-, deoxy-, and total hemoglobin concentrations ([HbO2], [Hb], and [tHb]), StO2, relative BF (rBF), and relative VO2 (rVO2) in the forearm flexor muscles. Absolute baseline BF and …
Fast Stochastic Wiener Filter For Super-Resolution Image Restoration With Information Theoretic Visual Quality Assessment, Amr Hussein Yousef, Jiang Li, Mohammad Karim, Mark Allen Neifeld (Ed.), Amit Ashok (Ed.)
Fast Stochastic Wiener Filter For Super-Resolution Image Restoration With Information Theoretic Visual Quality Assessment, Amr Hussein Yousef, Jiang Li, Mohammad Karim, Mark Allen Neifeld (Ed.), Amit Ashok (Ed.)
Electrical & Computer Engineering Faculty Publications
Super-resolution (SR) refers to reconstructing a single high resolution (HR) image from a set of subsampled, blurred and noisy low resolution (LR) images. The reconstructed image suffers from degradations such as blur, aliasing, photo-detector noise and registration and fusion error. Wiener filter can be used to remove artifacts and enhance the visual quality of the reconstructed images. In this paper, we introduce a new fast stochastic Wiener filter for SR reconstruction and restoration that can be implemented efficiently in the frequency domain. Our derivation depends on the continuous-discrete-continuous (CDC) model that represents most of the degradations encountered during the image-gathering …
Mathematical Model Development Of Super-Resolution Image Wiener Restoration, Amr H. Yousef, Jiang Li, Mohammad A. Karim
Mathematical Model Development Of Super-Resolution Image Wiener Restoration, Amr H. Yousef, Jiang Li, Mohammad A. Karim
Electrical & Computer Engineering Faculty Publications
In super-resolution (SR), a set of degraded low-resolution (LR) images are used to reconstruct a higher-resolution image that suffers from acquisition degradations. One way to boost SR images visual quality is to use restoration filters to remove reconstructed images artifacts. We propose an efficient method to optimally allocate the LR pixels on the high-resolution grid and introduce a mathematical derivation of a stochastic Wiener filter. It relies on the continuous-discrete-continuous model and is constrained by the periodic and nonperiodic interrelationships between the different frequency components of the proposed SR system. We analyze an end-to-end model and formulate the Wiener filter …
Multimodal Imaging Evidence For Axonal And Myelin Deterioration In Amnestic Mild Cognitive Impairment, Brian T. Gold, Yang Jiang, David K. Powell, Charles D. Smith
Multimodal Imaging Evidence For Axonal And Myelin Deterioration In Amnestic Mild Cognitive Impairment, Brian T. Gold, Yang Jiang, David K. Powell, Charles D. Smith
Neuroscience Faculty Publications
White matter (WM) microstructural declines have been demonstrated in Alzheimer's disease and amnestic mild cognitive impairment (aMCI). However, the pattern of WM microstructural changes in aMCI after controlling for WM atrophy is unknown. Here, we address this issue through joint consideration of aMCI alterations in fractional anisotropy, mean diffusivity, axial diffusivity, and radial diffusivity, as well as macrostructural volume in WM and gray matter compartments. Participants were 18 individuals with aMCI and 24 healthy seniors. Voxelwise analyses of diffusion tensor imaging data was carried out using tract-based spatial statistics (TBSS) and voxelwise analyses of high-resolution structural data was conducted using …