Center Pivot Irrigation In Nebraska: An Institutional Analysis Case Study, Thomas Nutt-Powell, Stewart Landers Dec 1979

Center Pivot Irrigation In Nebraska: An Institutional Analysis Case Study, Thomas Nutt-Powell, Stewart Landers

Biological Systems Engineering: Papers and Publications

This paper is one of a series resulting from institutional analysis of photovoltaic (PV) acceptance. It reports the results of a study of institutional factors influencing acceptance of center-pivot irrigation in the Nebraska agricultural community. Center-point irrigation (CP) was an interesting topic for study because (1) it was a major recently introduced technological innovation in agriculture which (2) had potentially detrimental attributes – water and energy intensity. A brief historical review of the introduction and acceptance of center-pivot irrigation in the Nebraska agricultural community is presented. Institutions which were a likely part of this institutional arena relative to CP introduction …


A Pressure Injection Device For Inoculation Of Maize With Bacterial Phytopathogens, Randall R. Carlson, A. K. Vidaver, D. S. Wysong, J. H. Riesselman Sep 1979

A Pressure Injection Device For Inoculation Of Maize With Bacterial Phytopathogens, Randall R. Carlson, A. K. Vidaver, D. S. Wysong, J. H. Riesselman

Biological Process Development Facility: Staff Publications

A pressure injection device (PID) was used to inoculate maize (Zea mays) with bacterial phytopathogens. The PID was evaluated for its speed, effectiveness, and precision relative to the needle-eye method of inoculation. Corynebacterium nebraskense, Erwinia stewartii, and Pseudomonas andropogonis were each used successfully as inocula to infect maize and produce symptoms typical of Goss's wilt, Stewart's wilt and bacterial stripe, respectively. Quantitative inoculation with the PID was faster and as statistically precise as using a calibrated needle-eye.


Maintaining A Septic Tank System, Elbert C. Dickey, Gary Hosek, Phillip W. Harlan Jun 1979

Maintaining A Septic Tank System, Elbert C. Dickey, Gary Hosek, Phillip W. Harlan

Biological Systems Engineering: Papers and Publications

Once a septic tank and absorption field are installed, you can do several things to prolong their life, thus protecting an investment which may cost $2500 or more. Here are several tips you can follow.

Often overlooked or neglected is the fact that septic tanks should be inspected at least once annually. In every properly functioning septic tank, sludge accumulates in the bottom. This sludge is composed of solid materials and must be removed periodically. If the sludge is not removed, the accumulated solids will build up in the septic tank and will begin to wash out into the absorption …


A Septic Tank System For Sewage Treatment, Elbert C. Dickey, Phillip W. Harlan, Gary Hosek Jun 1979

A Septic Tank System For Sewage Treatment, Elbert C. Dickey, Phillip W. Harlan, Gary Hosek

Biological Systems Engineering: Papers and Publications

A properly designed, installed ao1d maintained septic tank system is an approved method of sewage treatment for private residences in rural or urban areas where public sewage treatment systems are not available. The components of a septic system are the house sewer, the septic tank and the absorption field, as illustrated in Figure 1. Sewage flows to the septic tank through the house sewer. In the septic tank, the solids are separated from the liquids, undergo anaerobic digestion and are stored as sludge at the bottom of the tank. The liquid (septic tank effluent) flows to the absorption field …


A Comparative Analysis Of Intrusion Of Incisor Teeth Achieved In Adults And Children According To Facial Type, Ronald L. Otto Jun 1979

A Comparative Analysis Of Intrusion Of Incisor Teeth Achieved In Adults And Children According To Facial Type, Ronald L. Otto

Loma Linda University Electronic Theses, Dissertations & Projects

A comparison of incisor intrusion achieved in deep bite adults and children was made. Facial type was also examined for affect upon intrusion achieved. Fifty-five cases treated with Bioprogressive mechanics were studied cephalometrically, including twenty-four adults and thirty-one children. Neither age nor facial type was found to be statistically related to the amount of incisor intrusion achieved in this sample. A method of measuring intrusion at the root apices was devised which was felt to give a more accurate indication of actual bodily intrusion. More external root changes during treatment were observed for adults than for growing children. Wide latitude …


Elevation Of Ventricular Defibrillation Threshold In Dogs By Antiarrhythmic Drugs, Charles F. Babbs, Gkw Yim, S J. Whistler, W A. Tacker, L A. Geddes Jan 1979

Elevation Of Ventricular Defibrillation Threshold In Dogs By Antiarrhythmic Drugs, Charles F. Babbs, Gkw Yim, S J. Whistler, W A. Tacker, L A. Geddes

Weldon School of Biomedical Engineering Faculty Publications

Effects of antiarrhythmic drugs upon the threshold delivered energy (TDE) and threshold peak current (TPC) for electrical ventricular defibrillation by damped sinusoidal shocks were investigated in 25 pentobarbital-anesthetized dogs. TDE and TPC were increased by the three antiarrhythmic drugs tested. Bolus injections produced a transient rise, and continuous infusions produced a steady rise in defibrillation threshold. The maximal percent elevations in mean defibrillation threshold during the 60 minutes after intravenous drug treatment in groups of n = 5 dogs were: Treatment % increase in TDE % increase in TPC Lidocaine bolus (3 mg/kg) 48 26 Lidocaine (0.5 mg/Kg/min) 99 45 …


Measurements Of Young's Modulus Of Elasticity Of The Canine Aorta With Ultrasound, D J. Hughes, Charles F. Babbs, L A. Geddes, J D. Bourland Jan 1979

Measurements Of Young's Modulus Of Elasticity Of The Canine Aorta With Ultrasound, D J. Hughes, Charles F. Babbs, L A. Geddes, J D. Bourland

Weldon School of Biomedical Engineering Faculty Publications

We have developed an ultrasonic technique for determining the dynamic Young's modulus of elasticity (E) of the canine aorta in vivo. Young's modulus was measured in the descending thoracic aorta (DTA) and the abdominal aorta (AA) of 12 dogs over a range of mean blood pressures from 40-200 mmHg. The vessels were excised and dynamic moduli were determined in vitro postmortem from pressure-volume curves. The data so obtained were compared to the in vivo values. In vivo and in vitro moduli increased exponentially with mean distending pressure (P). The equation of best fit for these data was of the form …


Attenuation And Speed Of 10 Mhz Ultrasound In Canine Blood Of Various Packed Cell Volumes At 37c, D J. Hughes, L A. Geddes, Charles F. Babbs, J D. Bourland, V L. Newhouse Jan 1979

Attenuation And Speed Of 10 Mhz Ultrasound In Canine Blood Of Various Packed Cell Volumes At 37c, D J. Hughes, L A. Geddes, Charles F. Babbs, J D. Bourland, V L. Newhouse

Weldon School of Biomedical Engineering Faculty Publications

The attenuation coefficient and the speed of 10 MHz ultrasound were determined in canine blood at 37 oC by a differential path length technique. Blood specimens with packed cell volumes (PCV) ranging from 0 to 53% were prepared by separating the cells from the plasma and mixing the two components. The mean attenuation coefficient increased linearly with packed cell volume, the least squares regression function being  (dB/cm) = 0.992 +0.039 PCV with a standard error of the estimate = 0.255. The speed of 10 MHz ultrasound, c, in millimetres per second, increased with packed cell volume, the regression function …