Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Articles 1 - 4 of 4

Full-Text Articles in Biomedical Engineering and Bioengineering

Self-Assembly Of Gold Nanosphere Dimers By Inertial Force, George Andrew Christopher Sakhel Aug 2014

Self-Assembly Of Gold Nanosphere Dimers By Inertial Force, George Andrew Christopher Sakhel

Graduate Theses and Dissertations

The morphology and composition of a nanoparticle (NP) play a critical role in determining the NP's properties and function. To date, researchers have created a myriad of NPs of different shapes, sizes, and compositions with interesting attributes and applications ushering a revolution in medicine, electronics, microscopy, and microfluidics.

In this study, gold (Au) nanosphere dimers (NSDs) have been synthesized through a novel self-assembly method. These particles were created from Au NPs mono-dispersed in aqueous solution via a process of centrifugation and capping agent replacement. Au NSDs consist of two Au NPs combined together with minimal gaps between them. Optical spectral …


A Kinetic Study Of Anti-Vegf-A Polyclonal Antibodies And Anti-Vegf-A Ssdna Aptamers, Heather A. Hedeen Jun 2012

A Kinetic Study Of Anti-Vegf-A Polyclonal Antibodies And Anti-Vegf-A Ssdna Aptamers, Heather A. Hedeen

Master's Theses

A new detection reagent that could possibly augment or replace antibodies research and diagnosis methods are aptamers. Aptamers are ssDNA, RNA or polypeptide constructs that function like active antibodies. Antibodies and aptamers both specifically bind to selected target molecules, and as such they enable the detection or targeting of the presence or absence of a specific antigen.

In order to ensure that ssDNA aptamers perform similarly to antibodies, anti-VEGF-A polyclonal antibody and anti-VEGF-A ssDNA aptamer were evaluated against vascular endothelial growth factor A (VEGF-A) using Surface Plasmon Resonance (SPR). It was hypothesized that the anti-VEGF-A aptamer had the same, if …


Can Spr Be Used To Interrogate The Double Layer Of Nacl, Brandon Kawula Nov 2010

Can Spr Be Used To Interrogate The Double Layer Of Nacl, Brandon Kawula

Biomedical Engineering

Solutions of reagent grade salt .1, .01, .001, .0001, .00001M were run through a SPR to see if SPR had enough resolution to detect the formation of the electric double layer. We found that NaCl did in fact return a detectable signal. The signal shape seems to depend on concentration. While more study may need to be done to get definite information it looks like SPR can interrogate the double layer.


Integration Of Microfluidics With Surface Plasmon Resonance, Scott B. Fratzke Aug 2010

Integration Of Microfluidics With Surface Plasmon Resonance, Scott B. Fratzke

Master's Theses

This thesis successfully integrates laminate microfluidic devices with an analytic Surface Plasmon Resonance (SPR) instrument. Integration was accomplished at low-cost using materials such as polydimethylsiloxane (PDMS), Poly(methyl methacrylate) (PMMA), Tygon tubing, and a 3-way stopcock. The main components of this thesis are the design and fabrication of the low-cost, in-house fluidics that can integrate with upstream microfluidics and the validation of the in-house fluidics using the Biosensing Instruments BI-2000 SPR instrument. The low-cost fluidics was designed and fabricated “in-house” using a novel investment casting technique that required the use of laser cutting technology to make a master cast, and candle …