Open Access. Powered by Scholars. Published by Universities.®

Biomedical Engineering and Bioengineering Commons

Open Access. Powered by Scholars. Published by Universities.®

Theses/Dissertations

Other Mechanical Engineering

Institution
Keyword
Publication Year
Publication

Articles 1 - 27 of 27

Full-Text Articles in Biomedical Engineering and Bioengineering

Characterizing Tkr Biomechanics Using A Novel Muscle-Driven Joint Motion Simulator, Alexandre Galley Dec 2023

Characterizing Tkr Biomechanics Using A Novel Muscle-Driven Joint Motion Simulator, Alexandre Galley

Electronic Thesis and Dissertation Repository

Total knee replacement (TKR) is the end-stage treatment for severe cases of knee osteoarthritis (OA). Despite its success in alleviating pain and restoring mobility to the knee, patient satisfaction rates post-TKR are still lower than other common joint replacement surgeries. Knee kinematics and stability, key determinants of successful TKR, are assessed intraoperatively and tracked post-operatively in in vivo clinical studies. However, the persistently low satisfaction rates suggest that more sophisticated pre-clinical testing methods are needed to better understand the biomechanics of these implants early in their development. During pre-clinical testing of TKR implants, different joint motion simulators are used for …


Mechanical Design Of A Microwave Imaging Device For Breast Cancer Detection In Mri Scanners, Grace M. Player Jan 2023

Mechanical Design Of A Microwave Imaging Device For Breast Cancer Detection In Mri Scanners, Grace M. Player

Dartmouth College Master’s Theses

This project seeks to develop an updated version of a microwave imaging device for use in conjunction with breast MRI, improving upon existing technology and developing novel concepts for the device. It posits three primary redesign targets for updating the previous system: resizing the system height, making the device more iteration- friendly, and improving the overall manufacturability of the device by replacing custom components with commercially available alternatives. All three of these redesign targets are met in the new design, V2.0. The height is reduced by reducing antenna travel and height, embedding some components, and shortening the tank wall, resulting …


Structural Health Monitoring Of Bioprinted Materials, Kathryn H. Mcintosh Apr 2022

Structural Health Monitoring Of Bioprinted Materials, Kathryn H. Mcintosh

Honors College Theses

Bioprinting is a new method that utilizes additive manufacturing to construct organs, tissues, and other biostructures. This method presents endless possibilities - less reliance on organ donors (according to the Health Resources and Services Administration, 17 people die each day waiting for an organ transplant in the U.S.), more transplant opportunities, and the ability to save significantly more lives. While bioprinting has opened a new frontier in the biomedical field, there may be some research issues that need to be addressed. For example, numerous researchers have focused on creating novel approaches to print complicated geometries. However, the structural integrity or …


Numerical And Scaling Study On Application Of Inkjet Technology To Automotive Coating, Masoud Arabghahestani Dr. Jan 2022

Numerical And Scaling Study On Application Of Inkjet Technology To Automotive Coating, Masoud Arabghahestani Dr.

Theses and Dissertations--Mechanical Engineering

A thorough literature review identified lack of precision control over quality of droplets generated by the currently available industrial sprayers and a growing need for higher quality droplets in the coating industry. Particularly, lack of knowledge and understanding in continuous inkjets (CIJ) and drop-on-demand (DOD) technologies is identified as significant. Motivated by these needs, this dissertation is dedicated to computational fluid dynamics (CFD) and scaling studies to improve existing inkjet technologies and develop new designs of efficient coating with single and/or multiple piezoelectric sensors to produce on-demand droplets. This dissertation study aims at developing a new DOD type coating technology, …


Microparticle Propulsion For In Vivo Navigation, Louis Rogowski Dec 2020

Microparticle Propulsion For In Vivo Navigation, Louis Rogowski

Mechanical Engineering Research Theses and Dissertations

Microscale propulsion impacts a diverse array of fields, with simplistic microrobots allowing for novel innovations in microscale surgery and drug delivery. Propulsion at the microscale is constrained by physics, with time-reversal and geometric symmetries limiting available propulsion mechanisms. However, certain fluid environments and surface coatings allow for the propulsion of microparticles through externally applied magnetic fields. Presented here is a detailed analysis of microparticles propelling using spontaneous symmetry breaking, flagella surface coatings, and multi-modal actuation mechanisms. Spontaneous symmetry breaking in nonlinearly viscoelastic fluids is presented for the first time in literature, with two equal and opposite propulsion states existing along …


The Tera Multi Terrain Mobility Aid Chassis, Colton Kemp, Daniel Nicoll, Ibrahim Suleiman, Mohammad Alyami Jan 2020

The Tera Multi Terrain Mobility Aid Chassis, Colton Kemp, Daniel Nicoll, Ibrahim Suleiman, Mohammad Alyami

Williams Honors College, Honors Research Projects

The natural environment poses a significant number of obstacles and dynamic settings that makes mobility difficult for those with physical and mobility impairments. To approach this problem, a suspension was designed using inspiration from the early Mars rovers developed by NASA for traversing the varied Martian landscape. The course of the project followed the direction of a start-up through problem identification, early design generation and review, and final design production. The project outcome, through client request and proven market research, aimed to produce a multi-terrain wheelchair. The final product is a kinematic body with mobile front “legs” and a rotational …


System Integration Of C-Arm Robotic Prototype Using Motion Capture Guidance For Accurate Repositioning, Alireza Yazdanshenas Jul 2019

System Integration Of C-Arm Robotic Prototype Using Motion Capture Guidance For Accurate Repositioning, Alireza Yazdanshenas

Mechanical Engineering Theses

One of the important surgical tools in spinal surgery is the C-Arm X-ray System. The C-Arm is a large “C” shaped and manually maneuvered arm that provides surgeons and X-ray technicians the ability to take quick quality X-rays during surgery. Because of its five degrees of freedom, the C-Arm can be manually maneuvered around the patient to provide many angles and perspectives, ensuring surgical success.

This system works fine for most surgical procedures but falls short when the C-Arm must be moved out of the way for complicated surgical procedures.

The aim of this thesis is to develop an accurate …


Methods To Remotely Eliminate Biofilm From Medical Implants Using 2.4 Ghz Microwaves, Brett Glenn May 2019

Methods To Remotely Eliminate Biofilm From Medical Implants Using 2.4 Ghz Microwaves, Brett Glenn

Mechanical Engineering Undergraduate Honors Theses

Infections associated with biofilm growth are usually challenging to eradicate due to their high tolerance toward antibiotics [11, 12]. Biofilms often form on the inert surfaces of medically implanted devices [13]. No matter the sophistication, microbial infections can develop on all medical devices and tissue engineering constructs [12]. Related infections lead to 2 million cases annually in the U.S., costing the healthcare system over $5 billion in additional healthcare expenses [12].

Novel solutions to biofilm’s microbial colonization span the spectrum of engineering and science disciplines. Yet a practical solution still does not exist. The research presented here will explore a …


Final Design Report For The Bioburden Pre-Cleaning Device And Dr. Mark Rasnake At The University Of Tennessee Medical Center, Katherine Elizabeth Stiles, Megan Pitz, Kayla Franklin, Simran Dayal, Austin Bullock May 2019

Final Design Report For The Bioburden Pre-Cleaning Device And Dr. Mark Rasnake At The University Of Tennessee Medical Center, Katherine Elizabeth Stiles, Megan Pitz, Kayla Franklin, Simran Dayal, Austin Bullock

Chancellor’s Honors Program Projects

No abstract provided.


Development Of A Counter-Flow Thermal Gradient Microfluidic Device, Shayan Davani Feb 2019

Development Of A Counter-Flow Thermal Gradient Microfluidic Device, Shayan Davani

Doctoral Dissertations

This work presents a novel counter-flow design for thermal stabilization of microfluidic thermal reactors. In these reactors, precise control of temperature of the liquid sample is achieved by moving the liquid sample through the thermal zones established ideally through the conduction in the solid material of the device. The goal here is to establish a linear thermal distribution when there is no flow and to minimize the temperature change at flow condition. External convection as well as internal flowinduced effects influence the prescribed thermal distribution. The counter-flow thermal gradient device developed in this study is capable of both stabilizing the …


A Numerical Investigation Of Human Cough Jet Development And Droplet Dispersion, Ran Bi Apr 2018

A Numerical Investigation Of Human Cough Jet Development And Droplet Dispersion, Ran Bi

Electronic Thesis and Dissertation Repository

As part of the Western Cold and Flu aerosol (WeCoF) studies, the present study provides Computational Fluid Dynamics (CFD) modelling of human cough flow. The cough flow is characterized in two different aspects, the flow field and the droplets. In the study of the flow field of coughing, various dynamic characteristics, including the velocity variation, streamwise penetration and power spectral density, are examined. CFD simulations using two different approaches, the unsteady Reynolds Averaged Navier-Stokes (URANS) and the large eddy simulation (LES), are performed for comparison purposes. The numerical results are validated by the experimental data obtained from the measurements by …


Development Of Novel Models To Study Deep Brain Effects Of Cortical Transcranial Magnetic Stimulation, Farheen Syeda Jan 2018

Development Of Novel Models To Study Deep Brain Effects Of Cortical Transcranial Magnetic Stimulation, Farheen Syeda

Theses and Dissertations

Neurological disorders require varying types and degrees of treatments depending on the symptoms and underlying causes of the disease. Patients suffering from medication-refractory symptoms often undergo further treatment in the form of brain stimulation, e.g. electroconvulsive therapy (ECT), transcranial direct current stimulation (tDCS), deep brain stimulation (DBS), or transcranial magnetic stimulation (TMS). These treatments are popular and have been shown to relieve various symptoms for patients with neurological conditions. However, the underlying effects of the stimulation, and subsequently the causes of symptom-relief, are not very well understood. In particular, TMS is a non-invasive brain stimulation therapy which uses time-varying magnetic …


Experimental Measurements Of Far Field Cough Airflows Produced By Healthy And Influenza- Infected Human Subjects, Ahmed Faraj Alarbi Mohamed Sep 2017

Experimental Measurements Of Far Field Cough Airflows Produced By Healthy And Influenza- Infected Human Subjects, Ahmed Faraj Alarbi Mohamed

Electronic Thesis and Dissertation Repository

The present work details an experimental study of the cough airflow fields produced by subjects infected with influenza and when they are convalescent, together with data from healthy cohorts. The PIV and HWA measurements were taken far downstream at 1 m from the source within a cough chamber, along with droplet sampling at two different locations and nasal swabs from the sick subjects. The measured data over different seasons were used to evaluate and compare the results from sick, convalescent and healthy subjects. Although a total of 8 sick participants from winter 2014 and 2017 yielded positive nasal swab analysis, …


Biomechanics Of Concussion: The Importance Of Neck Tension, Ron Jadischke Jan 2017

Biomechanics Of Concussion: The Importance Of Neck Tension, Ron Jadischke

Wayne State University Dissertations

Linear and angular velocity and acceleration of the head are typically correlated to concussion. Despite improvements in helmet performance to reduce accelerations, a corresponding reduction in the incidence of concussion has not occurred (National Football League [NFL] 1996 – present).

There is compelling research that forces on and deformation to the brain stem are related to concussion. The brain stem is the center of control for respiration, blood pressure and heart rate and is the root of most cranial nerves. Injury to the brain stem is consistent with most symptoms of concussion reported in the National Football League and the …


Development Of A Finite Element Pelvis And Lower Extremity Model With Growth Plates For Pediatric Pedestrian Protection, Ming Shen Jan 2017

Development Of A Finite Element Pelvis And Lower Extremity Model With Growth Plates For Pediatric Pedestrian Protection, Ming Shen

Wayne State University Dissertations

Finite element (FE) model is a useful tool frequently used for investigating the injury mechanisms and designing protection countermeasures. At present, no 10 years old (YO) pedestrian FE model has been developed from appropriate anthropometries and validated against limitedly available impact response data. A 10 YO child FE pelvis and lower extremities (PLEX) model was established to fill the gap of lacking such models in this age group. The baseline model was validated against available pediatric postmortem human subjects (PMHS) test data and additional scaled adult data, then the PLEX model was integrated to build a whole-body FE model representing …


Computational Studies On Biomechanics Of Concussion And On Efficacy Of Football Helmets, David Labyak Jan 2017

Computational Studies On Biomechanics Of Concussion And On Efficacy Of Football Helmets, David Labyak

Dissertations, Master's Theses and Master's Reports

Football helmets have been used for many years to prevent head injuries to players. Over the years, the helmet design has evolved from a crude leather head covering to the more recent form fitting helmets that are seen today. The one design feature that has been common in the majority of all helmets is a hard polycarbonate shell with a foam cushion padding. The main goal of the padding layer was to reduce the amount of linear acceleration during an impact event. The one feature that has been overlooked is how stiff the padding is in rotation.

The purpose of …


Portable Sensory Room For The West Orange County Consortium For Special Education, Lindsey Chase, Emma Eskildsen, Alex Fox, Claire Francis, Nate Hoffman, Kaylee Keck, Sarah Sullivan Jun 2016

Portable Sensory Room For The West Orange County Consortium For Special Education, Lindsey Chase, Emma Eskildsen, Alex Fox, Claire Francis, Nate Hoffman, Kaylee Keck, Sarah Sullivan

Biomedical Engineering

This report discusses the development of a Portable Sensory Room to be used at Newland Elementary School in Huntington Beach. Newland Elementary has an exceptional Special Needs program that teaches the children with the most severe cases of autism in its school district. People with autism typically also have sensory processing disorders, which can be extremely disruptive for a child’s development and can make it difficult for a child to be able to concentrate long enough to gain necessary life skills. The idea behind a Sensory Rooms is to create a place to calm the students and to expose them …


Design And Analysis Of A Lift Assist Walker, Deep P. Shah Mar 2016

Design And Analysis Of A Lift Assist Walker, Deep P. Shah

Master's Theses

Walkers provided stability to the elderly but cannot assist a person from sitting to standing. The objective of this project is to present the design and analysis of a lift assist walker. This report discusses the design and analysis of a collapsible lift assist walker capable of lifting a patient up to 250 lbs. from seated to standing in under 10 seconds. The designed walker utilized a two stage scissor mechanism with a gas spring assisted embedded linear actuator.


Generation And Delivery Of Charged Aerosols To Infant Airways, Landon T. Holbrook Jan 2015

Generation And Delivery Of Charged Aerosols To Infant Airways, Landon T. Holbrook

Theses and Dissertations

The administration of pharmaceutical aerosols to infants on mechanical ventilation needs to be improved by increasing the efficiency of delivery devices and creating better ways of evaluating potential therapies. Aerosolized medicines such as surfactants have been administered to ventilated infants with mixed results, but studies have shown improvement in respiratory function with a much lower dose than with liquid instillation through an endotracheal tube (ETT). An aerosolized medicine must be transported through the ventilation tubing and deposit in the lungs to have the desired therapeutic response.

This work has taken a systematic approach to (i) develop new devices for the …


Development And Assessment Of An Impact Apparatus And High-Speed Camera Motion Tracking System To Quantify The Effect Of Static Muscle Loads On Fracture Threshold Measures In The Distal Radius, Jacob M. Reeves Aug 2013

Development And Assessment Of An Impact Apparatus And High-Speed Camera Motion Tracking System To Quantify The Effect Of Static Muscle Loads On Fracture Threshold Measures In The Distal Radius, Jacob M. Reeves

Electronic Thesis and Dissertation Repository

Distal radius fractures are prevalent, debilitating, and costly. This thesis conducts an in vitro investigation of these injuries, examining the role of static muscle loading on fracture threshold measures (i.e., force, impulse, energy). Initially, an impact apparatus and custom LabVIEW colour-thresholding program were designed and assessed for repeatability and accuracy in quantifying fracture measures and impact kinematics. These tools were then used to test six pairs of cadaveric forearms, with static muscle loads simulated in one specimen from each pair. Distal radius fractures were achieved in 5 pairs, with perilunate dislocations in the remaining pair. None of the …


Stent Graft Blush, Vanessa Barrett, Thomas Matzinger, Mike Morelli Jun 2013

Stent Graft Blush, Vanessa Barrett, Thomas Matzinger, Mike Morelli

Mechanical Engineering

In order to better understand Type IV endoleaks (“blush”), the Cal Poly Senior Project team GraftTest has developed a blush evaluation system able to mimic several of the aorta’s environmental parameters. Capable of both pressure and flow rate control, this bench top system accommodates Medtronic’s wide range of abdominal and thoracic aortic stent grafts. Having researched endoleaks, stent grafts, and numerous other factors affecting stent graft blush, a system was developed with the aim of assessing and comparing the performance of Medtronic’s stent grafts with regard to blush. Furthermore, this system has been designed to provide reliable and repeatable results …


Guidance System, Kayaking For The Visually Impaired, D. Ryan Kirtland, Ryan Phife, William Gardner, Amy Johnson Jun 2013

Guidance System, Kayaking For The Visually Impaired, D. Ryan Kirtland, Ryan Phife, William Gardner, Amy Johnson

Biomedical Engineering

Quality Life Plus is working with Team River Runner to develop an assistive guidance system for veterans who want to remain active by kayaking, after sustaining an injury that impairs vision. This system allows these veterans to complete a slalom speed race independent of a personal guide in the water. The system incorporates 3 stations that each contain a speaker connected to a microcontroller system covered by a Pelican Case on a custom made buoy. During the slalom race, a kayaker will travel from shore towards buoy #1 as it omits sound from the speaker. As the kayaker moves around …


Device For On-Site Production Of Sterile Water For Injection In A Disaster Zone, Chislon M. Richardson, Jeff Hebert Apr 2013

Device For On-Site Production Of Sterile Water For Injection In A Disaster Zone, Chislon M. Richardson, Jeff Hebert

Senior Theses and Projects

This project sought to design and produce a device for the on-site manufacture of sterile water to be subsequently used to produce IV fluid in disaster zone. In order to accomplish this, the water produced must be pure, sterile, non-pyrogenic, and satisfy the United States Pharmacopeia (USP) standard for water for injection (WFI). Ideally, the device should be low powered, low cost, robust yet portable and deliver at least 10 liters per hour. Our design incorporated the purification methods of carbon filtration, reverse osmosis and Ultra-violet treatment. However, due to power and cost constraints our device was neither able to …


Handitrike - Recumbent Tricycle, Sean Higginson, Kevin Howie, Vinay Patel Dec 2012

Handitrike - Recumbent Tricycle, Sean Higginson, Kevin Howie, Vinay Patel

Mechanical Engineering

This report covers the design and construction of the recumbent racing tricycle for Mr. Robert T. Kelly, a disabled veteran. Unfortunately Rob’s right leg is five inches shorter than his left one and therefore is unable to properly operate standard cranks. Our team HandiTrike is composed of Sean Higginson, Kevin Howie, and Vinay Patel and our project requires us to come up with a design that is feasible to complete within the given three quarters, as well as allow Rob to gain full use of his tricycle. Currently Rob ‘s trike uses the standard crank set up found on most …


Preoperative Planning Of Robotics-Assisted Minimally Invasive Cardiac Surgery Under Uncertainty, Hamidreza Azimian Aug 2012

Preoperative Planning Of Robotics-Assisted Minimally Invasive Cardiac Surgery Under Uncertainty, Hamidreza Azimian

Electronic Thesis and Dissertation Repository

In this thesis, a computational framework for patient-specific preoperative planning of Robotics-Assisted Minimally Invasive Cardiac Surgery (RAMICS) is developed. It is expected that preoperative planning of RAMICS will improve the rate of success by considering robot kinematics, patient-specific thoracic anatomy, and procedure-specific intraoperative conditions. Given the significant anatomical features localized in the preoperative computed tomography images of a patient's thorax, port locations and robot orientations (with respect to the patient's body coordinate frame) are determined to optimize characteristics such as dexterity, reachability, tool approach angles and maneuverability. In this thesis, two approaches for preoperative planning of RAMICS are proposed that …


Numerical Simulation And Experimentation Of Pulsatile Flows In Axisymmetric Arterial Models, Tadesse Gebreegziabher Jan 2012

Numerical Simulation And Experimentation Of Pulsatile Flows In Axisymmetric Arterial Models, Tadesse Gebreegziabher

Wayne State University Dissertations

ABSTRACT

NUMERICAL SIMULATION AND EXPERIMENTATION OF PULSATILE FLOWS IN AXISYMMETRIC ARTERIAL MODELS

by

TADESSE GEBREEGZIABHER

December 2011

Co-advisors: 1. Dr. Emmanuel Ayorinde 2. Dr. Trilochan Singh

Major: Mechanical Engineering

Degree: Doctor of Philosophy

The primary motivation for this dissertation is the fluid flow and structural response to unsteady blood flow in the human body. The research work is a synergistic merging of numerical simulation and experimentation. For the experiments, an all-encompassing, highly flexible experimental apparatus was designed and fabricated to facilitate a wide range of operating conditions, the range of which was chosen to accommodate mammalian cardiovascular system for both …


Finite Element Reconstruction Of Real World Aortic Injury In Near-Side Lateral Automotive Crashes With Conceptual Countermeasures, Aditya Neelakanta Belwadi Jan 2011

Finite Element Reconstruction Of Real World Aortic Injury In Near-Side Lateral Automotive Crashes With Conceptual Countermeasures, Aditya Neelakanta Belwadi

Wayne State University Dissertations

Traumatic rupture of the aorta (TRA) remains the second most common cause of death associated with motor vehicle crashes after brain injury. On an average, nearly 8,000 people die annually in the United States due to blunt injury to the aorta. It is observed that more than 80% of occupants who suffer an aortic injury die at the scene due to exsanguination into the chest. With the advent of more accurate and established human body finite element (FE) models, FE crash reconstruction methods may become a valuable tool when assessing crash scenarios and occupant injury mechanisms.

The current study is …